User manual ZYXEL PRESTIGE 100IH VERSION 2.20

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZYXEL PRESTIGE 100IH. We hope that this ZYXEL PRESTIGE 100IH user guide will be useful to you.


ZYXEL PRESTIGE 100IH VERSION 2.20: Download the complete user guide (777 Ko)

Manual abstract: user guide ZYXEL PRESTIGE 100IHVERSION 2.20

Detailed instructions for use are in the User's Guide.

[. . . ] Prestige 100 and 100IH User's Guide Version 2. 20 ZyXEL TOTAL INTERNET ACCESS SOLUTION Prestige 100 and 100IH ISDN Router and Router/Hub Prestige 100 and 100IH ISDN Router and Router/Hub Copyright Copyright © 2/26/1999 by ZyXEL Communications Corporation. The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, translated into any language, or transmitted in any form or by any means, electronic, mechanical, magnetic, optical, chemical, photocopying, manual, or otherwise, without the prior written permission of ZyXEL Communications Corporation. All rights reserved. Disclaimer ZyXEL does not assume any liability arising out of the application or use of any products, or software described herein. Neither does it convey any license under its patent rights nor the patent rights of others. [. . . ] Press space bar to toggle Yes/No Both Options Call Direction l Incoming l Outgoing Several other fields in this menu depend on this parameter. For example, in order to enable Callback, the Call Direction must be Both. Incoming: Rem Node Login Name Enter the login name that this remote node will use when it calls your Prestige. The login name in this field combined with the Rem Node Password will be used to authenticate this node. This field is applicable only if Call Direction is either Both or Incoming. This is the Calling Line ID (the telephone number of the calling party) of this remote node. If you enable the CLID Authen field in Menu 13 ­ Default Dial In, your Prestige will check the CLID in the incoming call against the CLIDs in the database. If no match is found and CLID Authen is Required, the call will be dropped. Incoming: Incoming: Rem Node Password Rem CLID Remote Node Configuration 4-3 Prestige 100 and 100IH ISDN Router and Router/Hub Incoming: Callback This field is applicable only if Call Direction is Both. This field determines whether or not your Prestige will call back after receiving a call from this remote node. If this option is enabled, your Prestige will disconnect the initial call from this node and call it back at the Outgoing Primary Phone Number (see below). Outgoing: My Login Name My Password Authen This is a required field [?] if Call Direction is either Both or Outgoing. Enter the login name for your Prestige when it calls this remote node. This is a required field [?] if Call Direction is either Both or Outgoing. Options for this field are: l l l Outgoing: Pri(mary) Sec(ondar y) Phone Numbers CHAP/PAP - Your Prestige will accept either CHAP or PAP when requested by this remote node. CHAP/PAP CHAP PAP Enable Disable Outgoing: Outgoing: Your Prestige always calls this remote node using the Primary Phone number first for a dial-up line. If the Primary Phone number is busy or does not answer, your Prestige will dial the Secondary Phone number if available. Some areas require dialing the pound sign # before the phone number for local calls. A # symbol may be included at the beginning of the phone numbers as required. Edit PPP Options To edit the PPP options for this remote node, move the cursor to this field, use the space bar to select Yes and press [Enter]. For more information on configuring PPP options, see the section Editing PPP Options. Enter the IP address of the remote gateway. Press space bar to toggle Yes then press [Enter] Rem IP Addr 4-4 Remote Node Configuration Prestige 100 and 100IH ISDN Router and Router/Hub Telco Options: Allocated Budget (min) Period (hr) Transfer Type This field sets a ceiling for outgoing call time for this remote node. This field sets the time interval to reset the above outgoing call budget control. This field specifies the type of connection between the Prestige and this remote node. [. . . ] 1. Check to see if the Prestige is connected to your computer's serial port. The communications software should be configured as follows: VT100 terminal emulation 9600 bps No parity, 8 Data bits, 1 Stop bit. Cannot access the Prestige via the console port. Troubleshooting 11-1 Prestige 100 and 100IH ISDN Router and Router/Hub 11. 2 Problems With the ISDN Line Table 11-2 Troubleshooting the ISDN Line Problem The ISDN initialization failed. This problem occurs when you attempt to save the parameters entered in menu 2, but receive the message, `Save successful, but Failed to initialize ISDN; Press ESC to exit'. Corrective Action Check the error log (in menu 24. 3. 1), you should see a log entry for the ISDN initialization failure in the format, `ISDN init failed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZYXEL PRESTIGE 100IH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZYXEL PRESTIGE 100IH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.