User manual ZYXEL NETATLAS ENTERPRISE QUICK START GUIDE V1.01

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZYXEL NETATLAS ENTERPRISE QUICK START GUIDE V1.01. We hope that this ZYXEL NETATLAS ENTERPRISE QUICK START GUIDE V1.01 user guide will be useful to you.


ZYXEL NETATLAS ENTERPRISE QUICK START GUIDE V1.01 : Download the complete user guide (839 Ko)

Manual abstract: user guide ZYXEL NETATLAS ENTERPRISE QUICK START GUIDE V1.01

Detailed instructions for use are in the User's Guide.

[. . . ] · CPU: Intel Pentium 4, 1. 6 GHz or above · Memory (RAM): 1 GB or more · Hard Disk free space: 20 GB or more · Screen Resolution: 1024x768 pixels · Ethernet Adaptor: 10/100 Mbps · Operating System: Windows 2000 (with service pack 1), Windows XP or Windows Server 2003 and all using NTFS file system. · Castle Rock's SNMPc 6. 09 (Enterprise or Workgroup edition) 2. 1 Device and Firmware Versions Supported1 The EMS supports the devices and device firmware versions as listed. · ES-3124: 360TP1C0 or later versions · ES-3124PWR: 360TY1C0 or later versions · ES-2024A: 360TX1C0 or later versions · GS-2024: 360LT0C0 or later versions 1. The list of devices and device firmware versions supported is accurate at the time of writing. [. . . ] To start SNMPc automatically each time you turn on your computer, click Config, System Startup, select Auto Startup and then click OK. Conversely, clear this check box if you do not wish SNMPc to automatically start each time you turn on your computer. 5 Adding MIBs The Management Information Base (MIB) is designed for holding management information on systems (such as the switch that the standard MIB does not include). 1 From the SNMPc Network Manager main screen, click Config, MIB Database. 2 In the Compile Mibs screen that displays, scroll down to the bottom of the Mibs to Compile list box and click Add. Note: If you have uninstalled an earlier version of NetAtlas EMS, you must remove zyxel. mib first. 3 Select the following MIBs in the Add Mibs list box: · · · · · · · rfc2674. mib rfc2925. mib rfc3291. mib rfc3621. mib zyxel-es3124. mib zyxel-es3124pwr. mib. zyxel-es2024a. mib 5 NetAtlas Enterprise Ethernet Switch Manager · zyxel-gs2024. mib 4 Click OK. 7 Finally click Done in the Compile Mibs screen. 6 Finding your Switch The SNMPc Network Manager can find new devices automatically using auto-discovery (enabled by default) or you will have to add device(s) manually. 6. 1 Device Auto-Discovery 1 To enable auto-discovery and then find your device, click Config, Discovery/Polling. Double-click the device icon to access the EMS. 6. 2 Add Device(s) Manually If you have disabled auto-discovery, follow the steps below to add your device(s) manually. 2 In the MAP Object Properties screen, enter a descriptive device name and IP address for the device and then click OK. 6 NetAtlas Enterprise Ethernet Switch Manager 7 Using SNMP Check that you are using SNMP Version 2c (SNMPv2c). If you are not using SNMPv2c, you must uninstall any previous versions and install SNMPv2c. 3 Set the specified fields in the Map Object Properties screen exactly as shown in the figure. Note: For security purposes, it is strongly recommend to change the Read Community and Read/Write Community defaults. Write down this information in a secure place so you will not forget it later! 4 Click OK. After the device has been found, the icon and label appear in the network manager view window. 5 Right-click on the device icon to view a set of SNMPc network manager shortcuts. Click Properties to verify the information you entered in the previous step. If it does not, click Start (or start), Programs, PostgreSQL 8. 0 and then click Start service. 7 NetAtlas Enterprise Ethernet Switch Manager 8 Accessing NetAtlas Follow the steps below to access NetAtlas. 1 In the SNMPc main screen, double-click the switch icon to view the Switch Manager. [. . . ] · Make sure your computer's Ethernet card is working properly. · If the problem still persists, uninstall and re-install the EMS software. 9. 1 Configuring the ODBC Driver The ODBC driver should already be installed from the EMS installation. You must configure the ODBC driver for the EMS to connect to the PostgreSQL database successfully. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZYXEL NETATLAS ENTERPRISE QUICK START GUIDE V1.01




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZYXEL NETATLAS ENTERPRISE QUICK START GUIDE V1.01 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.