User manual ZYXEL ES-1024A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZYXEL ES-1024A. We hope that this ZYXEL ES-1024A user guide will be useful to you.


ZYXEL ES-1024A : Download the complete user guide (395 Ko)

You may also download the following manuals related to this product:

   ZYXEL ES-1024A BROCHURE (129 ko)

Manual abstract: user guide ZYXEL ES-1024A

Detailed instructions for use are in the User's Guide.

[. . . ] To obtain the services of this warranty, contact ZyXEL's Service Center for your Return Material Authorization number (RMA). Any returned products without proof of purchase or those with an out-dated warranty will be repaired or replaced (at the discretion of ZyXEL) and the customer will be billed for parts and labor. All repaired or replaced products will be shipped by ZyXEL to the corresponding return address, Postage Paid. This warranty gives you specific legal rights, and you may also have other rights that vary from country to country. ZyXEL Limited Warranty iii Dimension ES-1016A/ES-1024A Ethernet Switch Interference Statements and Warnings FCC Interference Statement This device complies with Part 15 of the FCC rules. [. . . ] Auto-negotiating crossover for all 10/100Mbps Ethernet RJ-45 ports. The following are the essential features of the switch. Getting to Know Your Switch 1-1 Dimension ES-1016A/ES-1024A User's Guide · · · · · · · · · · IEEE 802. 1p supports two priority queues for outgoing traffic. Store-and-forwarding switching architecture for abnormal packet filtering. Standard 19-inch rack-mount design. 1. 2. 1 IEEE 802. 1p Class of Service The IEEE 802. 1p Class of Service (CoS) provides two queues for high and low priority traffic. This improves network efficiency and performance by giving higher priority to outgoing traffic. For example, the lower queue has a priority value in the range of zero to three and the higher queue has a priority value in the range four to seven. 1. 3 · · · · · · Package Contents ES-1016A/ES-1024A Ethernet switch Power cord Quickstart Guide This User's Guide in CD-ROM format. Four rubber feet Rack mount brackets Compare the contents of your ES package with the checklist below. If any item is missing or damaged, please contact your local dealer. 1. 4 Ethernet Switching Technology Ethernet Switching Technology has dramatically boosted the total bandwidth of a network, eliminated congestion problems inherent with CSMA/CD (Carrier Sense multiple access with Collision Detection) protocol, and greatly reduced unnecessary transmissions. This revolutionized networking in a number of ways: By allowing two-way, simultaneous transmissions over the same port (Full-duplex), which essentially doubled the bandwidth. Reducing the collision domain to a single switch-port, which eliminated the need for carrier sensing. Using the store-and-forward technology's approach of inspecting each packet to intercept corrupt or redundant data, switching eliminated unnecessary transmission that slowed the network. By employing address learning, which replaced the inefficient receiving port. 1-2 Getting to Know Your Switch Dimension ES-1016A/ES-1024A Ethernet Switch Auto-negotiation regulates the speed and duplex of each port, based on the capability of both devices. Flowcontrol allows transmission from a 100Mbps node to a 10Mbps node without loss of data. Auto-negotiation and flow-control may require disablement for some networking operations involves legacy equipment. Disabling the auto-negotiation is accomplished by fixing the speed or duplex of a port. Ethernet Switching Technology supplied higher performance at costs lower than other solutions. Wider bandwidth, no congestion, and the reduction in traffic is why switching is replacing expensive routers and inefficient hubs as the ultimate networking solution. 1. 5 1. 5. 1 Applications Standalone Workgroup This section provides two network topology examples in which the switch is used. The switch can be used as a standalone switch to which computers, servers and printer server are directly connected to form a small workgroup. Figure 1-3 Standalone Workgroup Example 1. 5. 2 Bridging With its large address table (4000 MAC address entries) and high performance, the switch is an ideal solution for department networks to connect to the corporate backbone or for connecting network segments. Getting to Know Your Switch 1-3 Dimension ES-1016A/ES-1024A User's Guide The following figure depicts a typical segment bridge application of the switch in an enterprise environment. The two workgroups, the standalone server and the two servers can all communicate with each other and share all network resources. Figure 1-4 Bridging Example 1-4 Getting to Know Your Switch Dimension ES-1016A/ES-1024A Ethernet Switch Chapter 2 Hardware Description and Installation This chapter describes the hardware installation and gives a functional overview of the switch. 2. 1 Installation Option The switch is suitable for an office environment where it can be rack mounted on standard EIA racks or as a standalone. For proper ventilation, allow at least 4 inches (10 cm) of clearance at the front and 3. 4 inches (8 cm) at the back of the switch. Step 2. Desktop Installation Make sure the switch is clean and dry. Set the switch on a smooth, leveled and sturdy flat space strong enough to support the weight of the switch and the connected cables. Make sure there is a power outlet nearby. Step 3. Make sure there is enough clearance around the switch to allow air circulation and the attachment of cables and the power cord. Step 4. These rubber feet help protect the switch from shock or vibration and ensure space between devices when stacking. Hardware Description and Installation 2-1 Dimension ES-1016A/ES-1024A User's Guide Figure 2-1 Attaching Rubber Feet Do not block the ventilation holes. 2. 1. 2 Rack-Mount Installation The switch can be mounted on an EIA standard size, 19-inch rack or in a wiring closet with other equipment. [. . . ] 5 cable EIA/TIA-568 100-ohm (100m) STP (100 m max. ) Full/Half Duplex Media Interface Exchange Full/Half duplex for 10/100Mbps speeds All ports are auto-crossover (auto-MDI-X) and auto-negotiating. Data Transfer Rate Network Cables Performance and Management Back plane Packet Forwarding Rate Switching Method Priority Queues MAC Address Table Data Buffer Non-Blocking full wire speed forwarding rate: ES-1016A: 3. 2Gbps ES-1024A: 4. 8Gbps 14880 PPS for 10BASE-T 148800 PPS for 100BASE-TX Store-and-forward IEEE 802. 1p Class of Service 4K Mac with Auto Learning 1. 25Mbits ES-1016A: 1. 4Kg ES-1024A: 1. 5Kg Physical and Environmental Weight Appendix A Dimension ES-1016A/ES-1024A User's Guide PRODUCT SPECIFICATIONS LED For the whole switch: PWR (green): Light on or off: Power on or off Ethernet ports: LNK/ACT, FDX/COL Bridging: 4K MAC addresses Switching Method: ES-1016A: 7. 2Gbps Layer 2 features ES-1024A: 8. 8Gbps Class of Service: IEEE 802. 1p Frame size: 1522 bytes Broadcast storm control Dimensions Power Supply Power Consumption Operating Temperature Operational Humidity EMI Safety 19" rack mountable enclosure 440(W) x 120(D) x 44(H) mm ES-1016A: 100-240VAC 50/60Hz 0. 8A MAX ES-1024A: 100-240VAC 50/60Hz 0. 8A MAX ES-1016A: 14W ES-1024A: 19W 0 C ~ 45 C (32ºF to 113ºF) 10% to 90% (Non-condensing) FCC Class A, CE UL, cUL o o B Appendix Dimension ES-1016A/ES-1024A Ethernet Switch Index 1 10 Mbps Ethernet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 A About the ES-1000 Series Ethernet to Ethernet Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Segment Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 C Cabling Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv class A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Contacting Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii D Data path loop. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Desktop Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Disclaimer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii E Ethernet Technology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 F Faulty cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 FCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv FCC Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Federal Communications Commission (FCC) Interference Statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Front Panel Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Front Panel LED Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Product Specifications General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A R Rack-Mount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Rear Panel Power Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Return Material Authorization number . . . . . . . . . . . . . . . iii RMA LED Descriptions FD/COL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 LK/ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 PWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 N Network Cable Length Limit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Network Cable Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 100Mbps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 10Mbps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Non-standard network cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 P Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 I IEEE 802. 1p. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Installation Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Rack-Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 L Index C Dimension ES-1016A/ES-1024A User's Guide Return Material Authorization number . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZYXEL ES-1024A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZYXEL ES-1024A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.