User manual ZEISS AXIOVERT 135

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZEISS AXIOVERT 135. We hope that this ZEISS AXIOVERT 135 user guide will be useful to you.


ZEISS AXIOVERT 135 : Download the complete user guide (2247 Ko)

Manual abstract: user guide ZEISS AXIOVERT 135

Detailed instructions for use are in the User's Guide.

[. . . ] All patenting rights are reserved. For further details, please contact: Carl Zeiss Microscopy D 07740 Jena Phone: ++49 3641 64 16 16 Telefax: ++49 3641 64 31 44 E mail: micro@zeiss. de Internet: www. zeiss. de/micro 3 Subject to change B 40 042 e 09/99 Contents Notes on the safe operation of the instrument . Transmitted light polarization Determining the n direction of oscillation . Transmitted light polarization Determining and measuring path differences . Transmitted light polarization Determining the optical characteristics of crystals . [. . . ] The click stops are set with the supplied Allen wrench on screw (4) (unscrew (4) to activate the click stop, screw it in to deactivate it). To prevent defocusing, clip plastic rings on the drive controls (2) and move the controls from the side. The attachable mechanical stage is always supplied with counterweight (9) which can be screwed on to the stage using the SW3 Allen wrench. It is used for symmetrical weight distribution and prevents defocusing when the stage is rotated. If it is not factory mounted, please refer to the leaflet supplied with the device. Fig. 32 Centering of Pol rotary stage 12 11 B 40 042 e 09/99 51 Microscope Components Condensers for Transmitted Light Overview Specification Achromatic aplanatic universal condenser 0. 9 Achromatic aplanatic universal condenser 0. 9 H D Ph Achromatic aplanatic universal condenser 0. 9 H D Ph DIC Comments highest flexibility and resolution; front lens swung in: for objectives 10x. . . 100x front lens swung out: for objectives 1. 5x . . . 10x brightfield insert or turret disk for contrasting elements with 5 or 7 positions Cat. no. 000000 1035 632 445436 0000 000 445439 0000 000 Achromatic aplanatic sSystem condensor 0. 24/d=10. 7 swing in Pol highest flexibility and resolution; front lens 0. 9 swung in: for objectives 10x . . . 100x 445325 9901 000 Achromatic switching condensor 0, 9 Achromatic switching condensor 0, 9 H D Ph Achromatic aplanatic condenser 1. 4 H DIC 000000 1017 688 For objectives A Plan 5x . . . 100x oil immersion on the illumination side for optimum resolution in transmitted light; fixed front lens; for brightfield and Differential Interference Contrast, for objectives 20x . . . 100x with iris diaphragm for aperture adjustment like 445443 0000 000, but motorized 000000 1017 690 445453 0000 000 also for phase contrast and darkfield 445443 0000 000 Achromatic condenser 0. 8 H Achromatic condenser 0. 8 H mot. 445444 0000 000 Achromatic condenser 0. 8 H D Ph DIC for brightfield, darkfield and phase contrast with objectives Ph 1, Ph2 and Ph3 DIC III fixed front lens; for objectives 5x . . . 100x; with iris diaphragm for aperture adjustment 445445 9901 000 13 52 B 40 042 e 09/99 Microscope Components Specification Achromatic condenser 0. 8 H D Ph mot. Comments like 445445 0000 000, but motorized Cat. Position turret disk with stop to be changed in the exchange opening and hold it on the knurled ring, since no click stop is effective in this position. Use mounting device contained in tool set to unscrew retainer ring (4) from the condenser underside (2) and allow phase stop (3) to slide out. To insert the new stop, turn condenser round, insert the new stop, and tighten retainer ring. The shiny glass underside of the stop must point downwards when the condenser is inserted. Loosen both centering screws and recenter stop using the centering telescope. Make sure that the correct label is visible on the knurled ring of the turret when the unit is swung into the beam path. Note: Phase or darkfield stops may only be inserted in centerable openings, DIC prisms only in openings with an iris stop. 36) The positions of the DIC prisms are marked with I, II, III. 1 1 2 3 5 4 1 2 3 4 5 Fig. 36 Cover on the underside DIC prism Prism mount Double function tool Groove Changing the DIC prism To loosen the cover on the condenser underside (1), loosen both grub screws using SW 2 screwdriver and remove the cover. Position turret disk with DIC prism to be changed in the exchange opening and hold it on the knurled ring, since no click stop is effective in this position. Screw threaded side (4) of the tool into the prism mount (3) and then pull out the DIC prism. Remove the DIC prism (2) from the tool and screw on the new, required prism. [. . . ] Only printable ASCII characters, and no binary coded data (except the carriage return as end character), are permitted. The first letter (always a capital letter) normally designates the function group, the second letter (capital = WRITE, small = READ) the actual funtion. All parameters are numeric (INTEGER, 8 bit ) and strings are permitted. String parameters are always last and are delimited by quota tion marks ("). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZEISS AXIOVERT 135




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZEISS AXIOVERT 135 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.