User manual ZEISS AXIOPHOT 2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZEISS AXIOPHOT 2. We hope that this ZEISS AXIOPHOT 2 user guide will be useful to you.


ZEISS AXIOPHOT 2 : Download the complete user guide (2243 Ko)

Manual abstract: user guide ZEISS AXIOPHOT 2

Detailed instructions for use are in the User's Guide.

[. . . ] Axioplan 2 imaging and Axiophot 2 Universal Microscopes Operating Manual 2 1 Knowledge of this manual is required for the operation of the instrument. Please therefore familiarize yourself with its contents and pay special regard to the sections dealing with the safe handling of the instrument. Unless expressly authorized, forwarding and duplication of this document, utilization and communication of its contents are not permitted. All rights reserved in the event of granting of patents or registration of a utility model. It is not permitted to pass on or copy this document, or to use or forward its contents unless prior consent has been provided. [. . . ] Condenser holder Z like 445340 0000 000, but motorized 445341 0000 000 to allow mounting of: ultracondenser 1. 2/1. 4 or dry darkfield condenser 0. 8/0. 95 445323 0000 000 Ultra condenser 1. 2/1. 4 special condenser for darkfield, high magnification 465500 0000 000 and apertue suitable for objectives with aperture (replaces 0. 75 . . . 1. 0 445315 0000 000) Dry darkfield con denser 0. 8/0. 95 special condenser for darkfield, medium magnifi cation and aperture special condenser for darkfield, medium magnification and aperture, suitable for objectives with aperture 0. 6 . . . 0. 75 for unilateral darkfield illumination at low magnifi cations between 1. 25x and 10x; switching to brightfield is possible 465505 0000 000 Darkfield illuminator 445314 0000 000 Condenser for photometry insert suitable ICS objective in condenser carrier for photometry 452126 0000 000 in preparation 12 11 B 40 042 e 09/99 53 Microscope Components Condenser carrier (Fig. 33) The condenser you selected is contained in the condenser car rier. These are its control elements: 1 2 3 o 8 4 o o 1 2 3 4 5 6 7 8 Fig. 33 7 6 Condenser carrier Height adjustment Clamping screw for the condenser Strain fr ee illumination optics Orientation notch Centering screw Stop for height adjustment Stop screw for height adjustment Condenser carrier 5 Height adjustment on both sides (max. The ease of motion is factory adjusted (to be changed only by the service staff). Clamping screw (3) for the condenser (used only for con denser exchange using SW 3 key). These are used to center the luminous field diaphragm image for the setting of KÖHLER illumination. To prevent the speci men from being pressed out of the object holder by mis take, the height movement of the condenser is limited by a stop screw. To prevent the specimen from being pressed upward out of the object holder, the height movement of the condenser is limited by a stop screw. The stop (7) is adjusted as follows: 1 Loosen stop screw (8), pin will fall downwards. Image the luminous field diaphragm (close it until it be comes visible). Move the condenser slightly upwards (diaphragm image becomes unsharp). Your specimen can now no longer be touched by the con denser. Achromatic aplanatic condenser system (Fig. 34) Depending on the version, the achromatic aplanatic universal condenser (1) is equipped with: - Fold out front lens - Turret disk for: brightfield - without or with DIC I, II, III darkfield - D phase contrast - Ph 1, Ph 2, Ph 3 interference contrast - DIC I, II, III - aperture diaphragm (iris stop) The front lens is folded in / out using lever (2). Turning the turret wheel (4) swings the brightfield insert and the contrast stops in the beam path. Slider (3) opens and closes the aperture diaphragm. 5 4 3 2 1 2 3 4 5 Universal condenser Lever to swing in/out the front lens Sliding knob for aperture diaphragm Window for turret position Turret wheel to swing in the brightfield insert or the contrast stops Condenser modules Fig. 34 13 54 B 40 042 e 09/99 Microscope Components Changing the phase stops or darkfield stops in the universal condenser (if required) (Fig. 35 Centering screws Cover on the underside Stop Retainer ring Changing the phase stop Tighten both centering screws (1) until stop using SW 1. 5 ball headed screwdriver. To loosen the cover on the condenser underside (2), loosen both grub screws using SW 2 screwdriver and remove the cover. Position turret disk with stop to be changed in the exchange opening and hold it on the knurled ring, since no click stop is effective in this position. Use mounting device contained in tool set to unscrew retainer ring (4) from the condenser underside (2) and allow phase stop (3) to slide out. [. . . ] If a syntax error occurs, all characters up to the next CARRIAGE RETURN are bypassed!Output format Each numeric or non numeric output is made in the ASCII for mat. Strings are transmitted without any special delimiters (quotation marks). The target address and source address is given before every number or every string, and the CARRIAGE RETURN character (Hex 0D) is then entered as the end character. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZEISS AXIOPHOT 2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZEISS AXIOPHOT 2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.