User manual ZANKER TT160A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZANKER TT160A. We hope that this ZANKER TT160A user guide will be useful to you.


ZANKER TT160A : Download the complete user guide (187 Ko)

You may also download the following manuals related to this product:

   ZANKER TT160A (183 ko)
   ZANKER TT160A (203 ko)
   ZANKER TT160A (183 ko)

Manual abstract: user guide ZANKER TT160A

Detailed instructions for use are in the User's Guide.

[. . . ] GEBRUIKSAANWIJZING MODE D`EMPLOI GEBRAUCHSANLEITUNG INSTRUCTION BOOK KOELKAST REFRIGERATEUR KÜHLSCHRANK REFRIGERATOR TT 160 A (TTI 160 C) NL FR DE GB 200365978 H/Z/8-3. (04. ) GB Before installing and using the appliance read this user's instruction book carefully. If the refrigerator is used in compliance with the instructions written, it will operate properly and provide you with greatest satisfaction. The symbols below help you to find things more easily: Safety precautions Warnings and information at this symbol serve safety for you and your appliance. Hints, useful information Environmental information Symbol for ideas At this symbol ideas can be found according to food and its storing. From the Electrolux Group. [. . . ] Unscrew the plate screw fixing the lamp cover, then take the lamp cover off in the direction of arrow and the bulb can be changed. (Type of the bulb: Mignon 322, 230 V, 15 W, E 14 thread) 50 GB After changing bulb replace the lamp cover, screw the plate screw and apply voltage to the appliance. We draw your attention that operation of appliance goes with certain sounds (compressor- and circulating sound). We draw it to your attention again that the appliance operates discontinuously, so the stopping of compressor does not mean being nocurrent. That is why you must not touch the electrical parts of the appliance before breaking the circuit. Solution Set higher position. Check if the appliance stands stable (all the four feet should be on the floor). If something does not work During operation of the appliance some smaller but annoying trouble can often occur, which does not require calling a technician out. In the following chart information is given about them to avoid unnecessary charges on service. Problem The appliance does not cool sufficiently Possible cause Thermostatic control is set too low. The thermostatic control is set too high. The appliance cools too hard The appliance does not cool at all The appliance is noisy Plug is not connected to the mains socket properly. The appliance is not supported properly. Inasmuch as the advice does not lead to result, call the nearest brand-mark service. Ins tr uctions f or the Ins t aller Technical data Model/Type Gross capacity (l) Net capacity (l) Width (mm) Height (mm) Depth (mm) Energy consumption T T 160 A (T TI 160 C) Fresh food comp. : 159 Fresh food comp. : 148 550 850 600 0, 41 150 A 90 34 (kWh/24h) (kWh/year) Energy class, according to EU standards Roted power (W) Weight (kg) Installing the appliance It is recommended to deliver the appliance in original packaging, in vertical position considering the protective warning on packaging. After each transportation the appliance must not be switched on for approx. In that case retain packaging. Cleaning Transportation, unpacking Remove every adhesive tape, which ensure the parts not to move in the appliance. Wash the inside of the appliance using lukewarm water and mild detergent. After cleaning wipe out the inside of the appliance. 51 GB Placement The ambient temperature has an effect on the energy consumption and proper operation of the appliance. When placing, take into consideration that it is practical to operate the appliance between ambient temperature limits according to the climate class that is given in the chart below and can be found in the data label. + 38 °C If the ambient temperature goes below the lower data the temperature of the cooling compartment can go beyond the prescribed temperature. If the ambient temperature goes beyond the upper data this means longer operating time of the compressor, breakdown in the automatic defrosting increasing temperature in the cooling compartment or increasing energy consumption. This can be achieved by two adjustable feet (1) at the bottom in front. 1-1 piece of distance washer (2) are accessories of the adjustable feet. Do not stand the appliance on a sunny place or close to a radiator or cooker. If it is unavoidable because of furnishing and the appliance has to be stood near a cooker take these minimum distances into consideration: In case of gas or electric cooker 3 cm must be left, when it is less put a 0, 5 - 1 cm non-flam insulation between the two appliances. In case of oil or coal-fired stove the distance must be 30 cms since they give off more heat. The refrigerator is designed to operate when it is totally pushed to the wall. [. . . ] The guarantee will not apply if damage caused to delicate parts, such as glass (vitreous ceramic), synthetic materials and rubber, is the result of inappropriate use. The guarantee cannot be called on for minor faults that do not affect the value or the overall reliability of the appliance. The statutory warranty does not apply when defects are caused by: a chemical or electrochemical reaction caused by water, abnormal environmental conditions in general, unsuitable operating conditions, contact with harsh substances. The guarantee does not apply to defects due to transport which have occurred outside of our responsibility. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANKER TT160A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANKER TT160A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.