User manual YORKVILLE NX300 SERVICE MANUAL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YORKVILLE NX300. We hope that this YORKVILLE NX300 user guide will be useful to you.
Manual abstract: user guide YORKVILLE NX300SERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] SERVICE MANUAL
nx300
WEB ACCESS: http://www. yorkville. com
WORLD HEADQUARTERS CANADA Yorkville Sound
550 Granite Court Pickering, Ontario L1W-3Y8 CANADA Voice: (905) 837-8481 Fax: (905) 837-8746
U. S. A. Yorkville Sound Inc.
4625 Witmer Industrial Estate Niagara Falls, New York 14305 USA Voice: (716) 297-2920 Fax: (716) 297-3689
Quality and Innovation Since 1963
Printed in Canada
Manual-Service-nx300-1v10. pdf
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE.
INSTRUCTIONS RELATIVES AU RISQUE DE FEU, CHOC ÉLECTRIQUE, OU BLESSURES AUX PERSONNES
AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE, N'ENLEVEZ PAS LE COUVERT (OU LE PANNEAU ARRIERE)
CAUTION:
AVIS:
NE CONTIENT AUCUNE PIECE REPARABLE PAR L'UTILISATEUR.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Read Instructions
The Owner's Manualshould be read and understood before operation of your unit. [. . . ] Follow the manufacturer's instructions when installing the product and use mounting accessories recommended by the manufacturer. The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be placed on the apparatus. Terminals marked with the "lightning bolt" are hazardous live; the external wiring connected to these terminals require installation by an instructed person or the use of ready made leads or cords. No naked flame sources, such as lighted candles, should be placed on the apparatus.
L'appareil ne doit être branché qu'à une source d'alimentation correspondant au voltage spécifié dans le manuel ou tel qu'indiqué sur l'appareil. Cet appareil est équipé d'une prise d'alimentation polarisée. Ne pas utiliser cet appareil avec un cordon de raccordement à moins qu'il soit possible d'insérer complètement les trois lames. Des précautions doivent êtres prises afin d'eviter que le système de mise à la terre de l'appareil ne soit désengagé.
Risque
Ne pas placer cet appareil sur un chariot, un support, un trépied ou une table instables. L'appareil pourrait tomber et blesser quelqu'un ou subir des dommages importants. Utiliser seulement un chariot, un support, un trépied ou une table recommandés par le fabricant ou vendus avec le produit. Suivre les instructions du fabricant pour installer l'appareil et utiliser les accessoires recommandés par le fabricant. Il convient de ne pas placer sur l'appareil de sources de flammes nues, telles que des bougies allumées. L'appeil ne doit pas être exposé à des égouttements d'eau ou des éclaboussures et qu'aucun objet rempli de liquide tel que des vases ne doit être placé sur l'appareil. Les dispositifs marqués d'une symbole "d'éclair" sont des parties dangereuses au toucher et que les câblages extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en utilisant des cordons déjà préparés.
Power Cord Service
The AC supply cord should be routed so that it is unlikely that it will be damaged. The unit should be serviced only by qualified service personnel.
Cordon d'Alimentation Service
safety-4v3. eps · Oct. [. . . ] Description Qty.
A
B
C
D
E
F
G
H
I
J
K
M1285. PCB_DATABASE_HISTORY
1
#1156 Bulb #1156 Bulb 3644 3644 B1 B2
2
1/4in JCK SLEEVE
J1
3924
LITE1 3641 Bayonet Bulb Socket
LITE2 3641 Bayonet Bulb Socket
22R .
18. W
R6
NX300 # DATE VER# DESCRIPTION OF CHANGE 1 JAN-03-2006 1. 00 FIRST RELEASE 2D V N 3D N V 4D V N 5D V N 6D N V 7D N V 8D N V 9D N V N 10 D V 11 D N V 12 D N V N V 13 D
Yorkville Sound
+20 +20
MODEL(S):-
1
2
+10
+10
3
L1
1/4in JCK SLEEVE
1000UH 3878
C2
140V 3U3
+0 +0
3
J2
3924
d B V
-10
-10 d B V
-20
-20
4
-30 -30
4
-40
-40
J4:A SPEAKON 4C 3628 1+ 2_
5
C1
250V 15U
-50 20 50 100 200 500 Hz 1k 2k 5k 10k 20k -50
SP2 #7457 15" 8R 300W PGM WOOFER L2
220UH 3780
1_ 2+ 3628 SPEAKON 4C J4:B
SP1 #7454 8R 40W 1" DRIVER HORN
5
J3:A
6
R1 8R2
.
R7 8R2
.
SPEAKON 4C 3628 1+ 2_ 1_ 2+ 3628 SPEAKON 4C J3:B
R9 R8 8R2 8R2
10. W
.
10. W
10. W
10. W
6
7
7
Product
8
NX300
PCB# M1285 Sheet 1 of 2
8
Date: Wed Jan 18, 2006 Filename: m1285-1V00. sch2002
A B C D E F G H I J
Rev: V1. 00
K
SOCKET SOCKET UPSIDE DOWN
M1285. PCB_DATABASE_HISTORY MODEL(S):-
J4
J3
M1285
NX300 NORMAL # DATE VER# DESCRIPTION OF CHANGE FIRST RELEASE 1 JAN-03-2006 1. 00 V N 2D NORMAL LARGE N V 3D V N 4D D V N SOCKET WITH DIRECTION 5 N V 6D V N 7D V N 8D TAB N V 9D V N 10 D V N 11 D N V 12 D V N 13 D M1285 DRILLING HISTORY M1285 PENDING CHANGES MODEL(S):# 1 2 3 4 5 6 PC# PC PC PC PC PC PC NX300 PENDING CHANGE X X X X X X MODEL(S):# 1 2 3 4 5 6 DATE D D D D D D NX300 VER# DESCRIPTION OF CHANGE V N V N V N V N V N V N
1/2
B2
So cke t
NX300 v1. 00
W5
5013
22R 18. W
R6
36 41
B1
LIT E1
Bu lb
So cke t
J1
J2
PCB CONN 4 CIR BOTTOM . 156
4
W1
3
Ba yo ne t
RT V
1
3903
TIP1
3924
TIP2
3924
TIP2
1
TIP1
2
M1285 2/2
H+ H- W- W+
NX300 v1. 00
C2
L2
3U3 140V 5949 RT V
W3
C1
R9
1000UH
0R000
4700
4700
8R2 10. W 8R2 10. W 8R2 10. W 8R2 10. W
RT V
IRON-L Inductor
R8
RT V
RT V
RT V
RT V
RT V
L1
W2
CLINCH ORIGIN INSERT ORIGIN
SHORT AXIS
R1
R7
INSIDE WIRE
RT V
SEE NOTE 3
VCD
LONG AXIS
3644 #1156 Bulb
W4
3644 #1156 Bulb
RT V
RT V
3628 111 PCB CONN 4 CIR BOTTOM . 156
Ba yo ne t
SPEAKON 4C 1+
NL4MP-1
11 1
RT V
SLEEVE
2+
Bu lb LIT E2
2+ 1+
15U 250V
2-
2-
36 41
RT V
3628 5867 11-
SPEAKON 4C 1+
NL4MP-1 SLEEVE
OUTSIDE WIRE
2+
2+ 1+
220UH 22AWG
22-
BlankSize - 15550x13850
*PLACE IMPLEMENTED CHANGES INTO BOARD HISTORY RED BLK
BLACK
YELLOW
NOTE: CONNECT YELLOW WIRE TO "HORN+" (YELLOW WIRE IS GROUND, HORN IS OUT OF PHASE)
PRODUCTION NOTES 1. USE M15. 525X13. 85 BAREBOARD EVEN THOUGH DIMENSION IS 15. 500 - SHOULDN'T MATTER SINCE NO VCD 3. LEAVE SPACE BETWEEN R1, R7, R8 AND R9
3538 3780 4700
StepAndRepeat - X3@5. 200Y1@0. 000
4700
3903
2 3 4
Pcb Mech M1285 Top Assy M1285
v1. 00 v1. 00
ETCH GUIDE [. . . ]