User manual YAMAHA DME4IO-ES

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YAMAHA DME4IO-ES. We hope that this YAMAHA DME4IO-ES user guide will be useful to you.


YAMAHA DME4IO-ES : Download the complete user guide (3683 Ko)

You may also download the following manuals related to this product:

   YAMAHA DME4IO-ES (2246 ko)
   YAMAHA DME4IO-ES (2248 ko)
   YAMAHA DME4IO-ES (2423 ko)
   YAMAHA DME4IO-ES (5509 ko)
   YAMAHA DME4IO-ES (3942 ko)

Manual abstract: user guide YAMAHA DME4IO-ES

Detailed instructions for use are in the User's Guide.

[. . . ] DIGITAL MIXING ENGINE SATELLITE Owner's Manual EN Explanation of Graphical Symbols CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The above warning is located on the top of the unit. IMPORTANT SAFETY INSTRUCTIONS 1 2 3 4 5 6 7 8 Read these instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. [. . . ] When mounting DME Satellite units in a rack, please leave one rack space vacant for every two units. You can attach a ventilation panel to this space or leave it open to prevent excessive heat build-up. If the temperature inside the rack is expected to rise above 40 degrees Celsius or 104 degrees Fahrenheit (or if the ambient temperature outside the rack is expected to rise above 30 degrees Celsius or 86 Fahrenheit), install a fan kit in the top row of the rack. The fan must provide airflow of 1. 6m3/min or more and static pressure of 5mmH2O or more. Foreword Foreword Introduction to the DME Satellite Controls and Connectors Connecting to a Computer Audio I/O Connection Connecting to an External Device Other Functions References Connecting to a Computer USB Connection To connect multiple DME Satellite units to a network, you must assign appropriate IP addresses and make other network settings on all units. To achieve this, you need to connect the [USB] connector of one of the DME Satellite units to the USB port of the computer using USB cables, install USB-MIDI Driver and DME Designer on the computer, then assign the IP addresses to the DME Satellite units from DME Designer. N OT E · Refer to the "DME Setup Manual" (PDF file) for details on installing USB-MIDI Driver and DME Designer. · Make sure that the USB-MIDI Driver's THRU setting is "OFF. " · Refer to "Network Settings" on page 19 for more information on assigning IP addresses from DME Designer. USB connections can be used in the following three ways: (1) Set up the network (e. g. , assign a unique IP address to each DME Satellite) from DME Designer. (3) Connect to any individual DME Satellite and control that DME Satellite unit by transmitting MIDI commands from a MIDI sequencer or similar software. N OT E · The computer on which DME Designer is running can be connected to either the group master or a slave DME series unit. · The correspondence between the MIDI commands to be received/transmitted and the scene parameters can be set up using DME Designer. · The USB port being used by DME Designer is not available for use by a MIDI sequencer or other application. Device Group USB Cable DME Satellite Ethernet Cable Switching Hub Ethernet Straight Cable Computer (Running DME Designer. ) Ethernet Cable DME64N/24N DME Satellite SCENE HOME UTILITY LEVEL MUTE CANCEL ENTER USB Cable Computer (Running MIDI Sequencer or similar application. ) 18 DME8i-ES/DME8o-ES/DME4io-ES Owner's Manual Connecting to a Computer Network Settings Use DME Designer to specify the IP address, master/slave, and master ID settings as follows. Setting the IP address Network Address Host Address Each group of digits between periods in an IP address is called an "octet. " These groups of digits are called "1st octet, " "2nd octet, " etc. , starting from the left-most digit group. You cannot specify 0, 127, or 223 through 255 for the 1st octet of the network address. Master : 2-253 Slave : 3-253 NO T E · Subnet mask is fixed at 255. 255. 255. 0. · The network address of Gateway is the same as that of IP address. · Assign each of DME series units a unique IP address so that there are no duplicates. · You cannot make any network settings while using the DME Designer application on-line. Refer to the DME Designer Owner's Manual for details. Master and slave setting Each device group must have one master. The fourth octet of a slave DME Satellite's master ID must be the same value as the fourth octet of the group master DME Satellite's IP address. NO T E DME8i-ES/DME8o-ES/DME4io-ES Owner's Manual 19 References Other Functions When using a DME Satellite together with the DME64N/24N, you must assign the DME Satellite (including the DME8i-C/ DME8o-C/DME4io-C) as the master. If you assign the DM64N/24N as the device group master, you will be unable to synchronize using DME Designer. Connecting to an External Device Audio I/O Connection Connecting to a Computer Controls and Connectors Introduction to the DME Satellite Foreword Foreword Introduction to the DME Satellite Controls and Connectors Connecting to a Computer Audio I/O Connection Connecting to an External Device Other Functions References Connecting to a Computer Ethernet Connection ([NETWORK] Connector) To control the DME Satellite from the computer via Ethernet, use an Ethernet cable to connect the [NETWORK] connector on the rear panel of the DME Satellite to the computer, then install DME-N Network Driver. N OT E · Refer to the "DME Setup Manual" (PDF file) for details on installing DME-N Network Driver. · Appropriate IP addresses must first be assigned to all devices connected to an Ethernet network. Connect your computer to one of the DME Satellite units via USB, then assign the IP addresses from DME Designer (page 18). Two DME Satellite units directly connected via Ethernet DME Satellite Ethernet Cable DME Satellite USB Cable You can connect devices in the same device group directly to each other using Ethernet cables, without connecting them to a switching hub. If they are DME Satellite units, you can use either crossover cables or straight cables. In this case, from DME Designer set Link Mode on both units to the same setting. Devices in different subnet (different network address) groups can be connected via a router or layer-3 compliant switching hub. HINT Since the DME Satellite supports Auto MDI/MDI-X, it will automatically detect whether the connected cable is of the straight type or crossover type, and will configure itself to create the optimal connection. [. . . ] Pour plus de détails sur les produits, veuillez-vous adresser à Yamaha ou au distributeur le plus proche de vous figurant dans la liste suivante. Die Einzelheiten zu Produkten sind bei Ihrer unten aufgeführten Niederlassung und bei Yamaha Vertragshändlern in den jeweiligen Bestimmungsländern erhältlich. Para detalles sobre productos, contacte su tienda Yamaha más cercana o el distribuidor autorizado que se lista debajo. NORTH AMERICA CANADA Yamaha Canada Music Ltd. 135 Milner Avenue, Scarborough, Ontario, M1S 3R1, Canada Tel: 416-298-1311 POLAND Yamaha Music Europe GmbH Branch Sp. z o. o. 17 Stycznia 56, PL-02-146 Warszawa, Poland Tel: 022-868-07-57 ASIA THE PEOPLE'S REPUBLIC OF CHINA Yamaha Music & Electronics (China) Co. , Ltd. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA DME4IO-ES




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA DME4IO-ES will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.