User manual YAMAHA DME4IO-C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YAMAHA DME4IO-C. We hope that this YAMAHA DME4IO-C user guide will be useful to you.


YAMAHA DME4IO-C : Download the complete user guide (3290 Ko)

You may also download the following manuals related to this product:

   YAMAHA DME4IO-C (2533 ko)
   YAMAHA DME4IO-C (2529 ko)
   YAMAHA DME4IO-C (2531 ko)
   YAMAHA DME4IO-C (6589 ko)
   YAMAHA DME4IO-C (3641 ko)
   YAMAHA DME4IO-C ANNEXE 3 (5325 ko)

Manual abstract: user guide YAMAHA DME4IO-C

Detailed instructions for use are in the User's Guide.

[. . . ] DIGITAL MIXING ENGINE SATELLITE Owner's Manual EN Explanation of Graphical Symbols CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The above warning is located on the top of the unit. IMPORTANT SAFETY INSTRUCTIONS 1 2 3 4 5 6 7 8 Read these instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. [. . . ] The indicators on both sides to the CobraNet connectors are turned off. · Use a STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. 7 MAC Address This is the CobraNet's MAC (Media Access Control) address. 8 [GPI] Connector This Euroblock connector provides access to the unit's GPI (General Purpose Interface) interface for transfer of control signals to and from external equipment. The OUT terminals output either signal "L" or "H" at a TTL level. (See page 34. ) 9 [INPUT] Connectors These Euroblock connectors receive 8-channel analog audio signals on the DME8i-C. These Euroblock connectors receive 4-channel analog audio signals on the DME4io-C. NOT E · The PAD will be internally switched on or off when the gain of the DME8i-C/DME4io-C internal head amp is adjusted between ­6 dB and ­5 dB. Keep in mind that noise may be generated if there is a difference between the Hot and Cold output impedance of the external device connected to the INPUT connector when using phantom power. DME8i-C/DME8o-C/DME4io-C Owner's Manual 21 References ) [OUTPUT] Connectors These Euroblock connectors output 8-channel analog audio signals on the DME8o-C. These Euroblock connectors output 4-channel analog audio signals on the DME4io-C. Other Functions Connecting to an External Device Audio I/O Connection Connecting to a Computer Controls and Connectors Introduction to the DME Satellite Foreword Foreword Introduction to the DME Satellite Controls and Connectors Connecting to a Computer Audio I/O Connection Connecting to an External Device Other Functions References Connecting to a Computer USB Connection To connect multiple DME Satellite units to a network, you must assign appropriate IP addresses and make other network settings on all units. To achieve this, you need to connect the [USB] connector of one of the DME Satellite units to the USB port of the computer using USB cables, install USB-MIDI Driver and DME Designer on the computer, then assign the IP addresses to the DME Satellite units from DME Designer. N OT E · Refer to the "DME Setup Manual" (PDF file) for details on installing USB-MIDI Driver and DME Designer. · Make sure that the USB-MIDI Driver's THRU setting is "OFF. " · Refer to "Network Settings" on page 23 for more information on assigning IP addresses from DME Designer. USB connections can be used in the following three ways: (1) Set up the network (e. g. , assign a unique IP address to each DME Satellite) from DME Designer. (3) Connect to any individual DME Satellite and control that DME Satellite unit by transmitting MIDI commands from a MIDI sequencer or similar software. N OT E · When using a DME Satellite together with the DME64N/24N, you must assign the DME Satellite (including the DME8iES/DME8o-ES/DME4io-ES) as the master. · The computer on which DME Designer is running can be connected to either the group master or a slave DME series unit. · The correspondence between the MIDI commands to be received/transmitted and the scene parameters can be set up using DME Designer. · The USB port being used by DME Designer is not available for use by a MIDI sequencer or other application. Device Group USB USB Cable INPUT PEAK SIGNAL PEAK SIGNAL PEAK SIGNAL PEAK SIGNAL PEAK SIGNAL PEAK SIGNAL DIGITAL MIXING ENGINE SATELLITE INPUT DME Satellite Ethernet Cable Switching Hub Ethernet Straight Cable Computer (Running DME Designer. ) Ethernet Cable DME64N/24N INPUT PEAK PEAK SIGNAL PEAK SIGNAL PEAK SIGNAL PEAK SIGNAL DIGITAL MIXING ENGINE SATELLITE USB SIGNAL PEAK SIGNAL INPUT DME Satellite SCENE HOME UTILITY LEVEL MUTE CANCEL ENTER USB Cable Computer (Running MIDI Sequencer or similar application. ) 22 DME8i-C/DME8o-C/DME4io-C Owner's Manual Connecting to a Computer Network Settings Use DME Designer to specify the IP address, master/slave, and master ID settings as follows. Introduction to the DME Satellite Setting the IP address Network Address Host Address Each group of digits between periods in an IP address is called an "octet. " These groups of digits are called "1st octet, " "2nd octet, " etc. , starting from the left-most digit group. You cannot specify 0, 127, or 223 through 255 for the 1st octet of the network address. Master : 2-253 Slave : 3-253 NO T E · Subnet mask is fixed at 255. 255. 255. 0. · The network address of Gateway is the same as that of IP address. · Assign each of DME series units a unique IP address so that there are no duplicates. · You cannot make any network settings while using the DME Designer application on-line. · If you have connected a PM5D and a DME Satellite via CobraNet and are controlling the DME Satellite from the PM5D, you must specify a value of 2 as the fourth octet of the group master DME Satellite's IP address. However, if the PM5D is version 2. 20 or higher and the DME Satellite is version 3. 07 or higher, you can set the parameter to any number. Master and slave setting Each device group must have one master. The fourth octet of a slave DME Satellite's master ID must be the same value as the fourth octet of the group master DME Satellite's IP address. NO T E When using a DME Satellite together with the DME64N/24N, you must assign the DME Satellite (including the DME8iES/DME8o-ES/DME4io-ES) as the master. [. . . ] 10 50 DME8i-C/DME8o-C/DME4io-C Owner's Manual For details of products, please contact your nearest Yamaha representative or the authorized distributor listed below. Pour plus de détails sur les produits, veuillez-vous adresser à Yamaha ou au distributeur le plus proche de vous figurant dans la liste suivante. Die Einzelheiten zu Produkten sind bei Ihrer unten aufgeführten Niederlassung und bei Yamaha Vertragshändlern in den jeweiligen Bestimmungsländern erhältlich. Para detalles sobre productos, contacte su tienda Yamaha más cercana o el distribuidor autorizado que se lista debajo. NORTH AMERICA CANADA Yamaha Canada Music Ltd. 135 Milner Avenue, Scarborough, Ontario, M1S 3R1, Canada Tel: 416-298-1311 POLAND Yamaha Music Europe GmbH Branch Sp. z o. o. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA DME4IO-C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA DME4IO-C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.