User manual WELLTECH WELLGATE 2626 V1.00

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WELLTECH WELLGATE 2626. We hope that this WELLTECH WELLGATE 2626 user guide will be useful to you.


WELLTECH WELLGATE 2626 V1.00: Download the complete user guide (2196 Ko)

Manual abstract: user guide WELLTECH WELLGATE 2626V1.00

Detailed instructions for use are in the User's Guide.

[. . . ] Telephony port (RJ-11) 2-FXO Ports, to connect with PSTN Line 6-FXS ports, as PABX Extension Line to connect with analog phone Reset button (Factory Default) AC power Jack Status indicated LED Indicates Ethernet, FXO, FXS, and SIP system status Features: Support Stand-Along Working without Network Connection Ready to Run Default Settings Copyright © 2007 Welltech Computer Co. , Ltd. All right reserved. 2 WellGate 2626 User Manual EN-V1. 00 SIP RFC 3261 Compliance Audio Codec: G. 711, G. 723. 1, G. 729A In-band and out of band DTMF relay Support SIP Register and Calling Support Backup SIP Proxy Server G. 168 Echo Cancelation T. 38 Fax Relay DTMF/FSK Caller ID Detection and Generation Intelligent Call Routing Support Backup Route to PSTN when VOIP or Network is failed Support Emergency Call Through PSTN Provides Configurable Auto Attendant Service Support Direct Route to Operator Support Operator Hunting Based on Priority Support Operator Simultaneously Ringing Customizable Auto Attendant Greeting Call Transfer Call Hold Call Forward Environmental Operating Temp. & Humidity Temp. : 045 (32113) Humidity: 1085% relative humidity, non-condensing AC Power Adaptor: INPUT: AC100V-240V, 50/60Hz OUTPUT: DC 12V, 3. 0A Default IP Address WAN IP : 10. 1. 1. 3 LAN IP : 192. 168. 123. 123 Ready To Run Default Settings: T1: 21* T2: 22* T3: 23 *default operator T4: 24 T5: 25 T6: 26 All outgoing calls are route to PSTN automatically All incoming call is answered by Auto Attendant Press 9 for operator and # for end of dialing Copyright © 2007 Welltech Computer Co. , Ltd. All right reserved. 3 WellGate 2626 User Manual EN-V1. 00 Appearance 1. [. . . ] The codec priority will be G. 711, G. 729 and G. 723 The default setting is "Regular". Press the "Apply" button (at the bottom) after you finish to save changes. Press the "Reboot" button to apply the changes. Copyright © 2007 Welltech Computer Co. , Ltd. All right reserved. 14 WellGate 2626 User Manual EN-V1. 00 Service_Extension Line (Figure 11) In the "Service_Extension Line Setting" section (see figure 11), you can set the operator priority of the extensions for incoming call. The detail instruction explained below: Caller ID Enable or Disable the Caller ID Sending to Telephone Set. You have to use Caller ID phone in order to display the caller information. Caller ID Type Specify the caller ID Type of your phone set : DTMF, FSK(Bellcore), ETSI(Before Ring) or ETSI(Between Ring) Specify the Operator Ring Mode: 1. "Priority Ring" : The operator will be hunted based on the priority defined in extension. If the higher priority's extension is busy, the call will automatically hunt to second one and so on. Simultaneous Ring: Parallel Ring all priority of operators' extension, exclude those extension's operator set to "NA". All right reserved. 15 Operator Ring Mode WellGate 2626 User Manual EN-V1. 00 Ring Time Specify ring time : 5~60 sec. It is used for priority hunting which define how long the system will think the ringing operator is not able to take the call and hunt to next. Operator Short Code TEL 1 ~TEL6 Line Number Operator Specify the extension number Specify the Operator priority of incoming call; you can set the priority from 1st to 6th or "NA" for extension. Forward Condition Specify the extensions forward condition, you can choose the following: Disable UNCONDITIONAL BUSY NO ANSWER BUSY + NO ANSWER Forward TEL Specify the forward extension number Specify the short code of Operator (eg. Press the "Apply" button (at the bottom) after you finish to save changes. Press the "Reboot" button to apply the changes. Copyright © 2007 Welltech Computer Co. , Ltd. All right reserved. 16 WellGate 2626 User Manual EN-V1. 00 Service_PSTN Line (Figure 12) In the "Service_PSTN Line " section (see figure 12), you can define the routing rule of incoming/outgoing PSTN call, the detail information please refer to the table below. PSTN Line Setting PSTN incoming Route PSTN Call Notice Specify the PSTN incoming call routing rule, via IVR or direct to operator. If you Select "Yes", system will send a PSTN call notice tone before dialing when the SIP trunk (Ethernet) is fail. Specify the location of WG2626, Click the "Use" icon when you select the correct country. System will use the selected country's PSTN tone to become the active value. Route Setting Those prefix defined here, will be route to PSTN no matter VOIP is active or not. 17 Disconnect Tone Country Template Copyright © 2007 Welltech Computer Co. , Ltd. [. . . ] Under Management => Upgrade firmware web menu (see figure 21), specify the location of the firmware by clicking the Browse button next to the Http Upload text box. You will be prompted with a window requesting the location of the firmware. Back in the web configuration menu, press the Start button (next to the Http Upload's browse button) to execute the upgrade process. After the update process is finish, you will be taken to a web page indicating that it was successful. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WELLTECH WELLGATE 2626




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WELLTECH WELLGATE 2626 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.