User manual WAVECOM WINPATS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WAVECOM WINPATS. We hope that this WAVECOM WINPATS user guide will be useful to you.


WAVECOM WINPATS : Download the complete user guide (400 Ko)

Manual abstract: user guide WAVECOM WINPATS

Detailed instructions for use are in the User's Guide.

[. . . ] REVISION 1. 87 +, MARCH 2000 1996 WAVECOM INSTRUMENTS PTY LTD Product Developed by Wavecom Instruments Pty Ltd 45 Charles St Norwood S. A. 5067 Ph 08 8331 8892 Fax 08 8331 3648 E-mail: admin@wavecom. com. au WEB PAGE www. wavecom. com. au 1 INDEX 1. INSTALLATION PROCEDURE OF WinPATSTM OPENING THE PROGRAM LOGIN THE MAIN PROCESSING SCREEN MENU INFORMATION EQUIPMENT MENU COMMUNICATION MENU REPORTS REGISTRY SORT ADMINISRATION HELP THE RCD SCREEN SCANNER / SMART WAND OPTION ERROR MESSAGES Getting Started Handy tips · Tab Key takes you to the next sequential data entry field. · A menu name with a underscore letter can be called using Alt+letter underscored e. g. File menu is activated by pressing Alt key simultaneously with the F key. [. . . ] Wand & BHT 5000 are options and will only appear if you have ordered these options. SAVE settings, this allows for by passing the above procedure next time you plug in your tester. 7. 2 Get From Pat - Click on Get From Pat or Press Alt + G This function allows you to enter the DOWN LOAD screen. Down loading of test, results and entering of new equipment can be entered here. Fig 19. This screen has the following features: The down load Grid: This grid contains the following information about every test downloaded from the Pats tester Unit. This flag is used when the current record has been through the update process. These numbers are automatically generated by the Pats Unit. 14 NRNo register flag. This flag is used by the operator when user wants the current test recorded to the history but does not want to show in any reports or to affect other data because of processing. This flag signifies that the current test is an intermediate test i. e. a test done before the due date, however record in the history details and does not affect any other data because of processing. Can be MANual or TEST or AUTO, as set by the operator of the Pats Unit at time of testing. User Identification number, as set by the operator at time of testing. The Serial number from the TESTER is required by the program to maintain traceability of test results. This option allows the user to nominate a range of tests to be updated. The user wishes to nominate say tests 1-25 to be updated for one particular site he enters 1 in the From box to 25 in the To box, then proceeds to select the site where the items belongs. Click update and the Items 1 to25 will be checked of and if found in that site. If tests 26 ­30 belong to another site then replace the from/to numbers to SEQ 26-30 select the new site and continue as above. Do this until all records are updated and then it is safe to clear test result grid. Method: Clear: Append: This option clears the down load grid before a new down load occurs. NOTE: make sure you have updated all the test results before CLEARING. must be in the UPD box This option appends new down loaded data, to the current data in the down load grid, when a new down load occurs. It is recommended that you clear this regularly as it will just become huge and difficult to manipulate. Fig 21. No Chars of PNO: This option allows the user to nominate how may characters the Part number is to be padded out when down loading from the Pats Unit. if 6 then if a part number inputted by the operator of the Pats Units is say 101 then the program will convert 101 to 000101. This is a critical issue and must be understood selecting the No. Chars can make a difference in whether you need to down load again or not. 15 DEFAULT option Clicking this option will down load the numbers from the PAT tester with only the numbers starting at the digit. These numbers can be from one digit to 10 digits long all prefixed zeros are ignored. [. . . ] Select the group of Numbers you wish to change using a query then apply the Increase or Decrease function. 11. 4. Administration Fix Part No. 12. 0 Help Recommend you use this Manual for the Latest Information and Accuracy. Help - Click on Help Menu or Press Alt + H Contents - Click on Contents or Press Alt + C This option displays the contents of the help file. Index - Click on Index or Press Alt + I This option displays the index of the help file. Search For Help - Click on Search or Press Alt + S This option displays the windows help file. Legend This option displays a screen, which explains what the different colours mean on the equipment grid. - Click on Legend or Press Alt + L 27 13. (If Option Fitted) This option is only visible via the EQUIPMENT TYPE Table. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WAVECOM WINPATS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WAVECOM WINPATS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.