User manual VESTAX PT-X1000A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VESTAX PT-X1000A. We hope that this VESTAX PT-X1000A user guide will be useful to you.


VESTAX PT-X1000A : Download the complete user guide (197 Ko)

Manual abstract: user guide VESTAX PT-X1000A

Detailed instructions for use are in the User's Guide.

[. . . ] Temperature Avoid use in hot, (over 35 )and cold, (below 5 ) locations. Keep the unit away from extreme direct heat such as direct sunlight, heating radiators, or closed vehicles. Power cord handling Connecting the power cord to other cords or joining cords together can cause fire and electric shock. [. . . ] Keep away from liquids Do not stand cans containing liquids on or near the equipment. If liquid enters equipment, disconnect the power cord from the power outlet immediately. WARRANTY The warranty might vary from country to country. Each distributor has their own warranty system in accordance with the country or state regulations or laws. VESTAX observes the manufacturing country s regulations. FEATURES Three band isolator switch kills each frequency range completely in quick action. Pre / Post selectable AUX send switch enables various effect processing. The effect signal can be controlled by a dedicated return level control knob, the signal can be also monitored by headphone when "return" is selected by cue button. Three phono and 6 line inputs are provided to meet the new mixing style with various input source. The new PT-X1000A features removable flat panel that covers all screws etc. , That will impede fast mixing. New superior grade crossfader (CF-PCV) fitted to PT-X1000A enabling super smooth operation together with long life. Different signal routes can be selected this switch to different positions. P R E : The signal before the input fader (after the EQ) will be sent to AUX output. POST : The signal after the input and cross fader will be sent to AUX output. O F F : No signal will be sent to AUX output. -16dB +16dB EFFECT 5 6 PRE OFF POST CUE OFF SIGNAL ON 6 CUE SWITCH Used to send the signal from each program to monitor section for headphone monitoring. 7 LEVEL 10 9 8 7 6 INPUT FADER Used to adjust the Input level of each program. Replace with the IF-175 when it is worn out. 8 CROSS FADER When the Input level of PGM1 and PGM2 are properly set, PGM1 will be heard with the cross fader set to the left side. When the cross fader is set in the center, both programs will be heard. This is detachable fader for the ease of replacement with "CF-PCV" when it is worn out. 7 5 4 3 2 1 0 CF-PCV For PMC SERIES ( PMC05ProII, PMC06ProA, etc) Insert the multi-cable connector Set side switch to "PCV" position. PMC CONNECTOR Set switch to "PMC" position 4 HOW TO CHANGE THE FADER UNIT HOW TO REMOVE THE TOP PANEL 1 Remove each fader knobs and 10 screws which HOW TO CHANGE THE FADER UNIT 1 Remove the screws on the fader panel. 3 Carefully remove the multi-cable connector from fix the top panel. 2 Remove the top panel. Driver fader unit. 4 Attach multi-cable connector to new fader unit. 5 Position the fader unit Driver carefully and secure with screws. Top panel Main panel MICROPHONE, SUB INPUT SECTION LINE 4 IN 9 L R 9 LINE INPUT JACK(LINE4) Input connectors for line level equipment such as CD players, tape decks , DATs, or MDs etc. MIC 10 MIC-1 MIC-2 10 11 12 13 MIC INPUT JACK(MIC1, 2) Input jacks of mic1, mic2. MIC-1 MIC LEVEL Adjusts the input level from all of the microphone inputs. 11 MIN MAX MIC EQUALIZER(HI, LOW) Adjusts the HI and LOW frequencies for all of the microphone input. MIC-2 MIN MAX EFFECT SWITCH Used when sending signal to the external effect processor connected to the effect SEND/RETURN. EQ HI 12 -16dB +16dB 14 CUE SWITCH Used to send the signal from the mic channel to the monitor section for headphone monitoring. LO -16dB +16dB EFFECT 13 14 OFF POST CUE OFF ON 5 MASTER SECTION 15 MASTER OUT LEVEL METER The LED level meters indicate the signal level of the line out. 16 16 MASTER +8 +5 +3 +1 0 +8 +5 +3 +1 0 -1 -3 -5 -7 -10 -15 POWER CUE CUE LEVEL METER The LED level meters indicate the signal level of PGM input selected by CUE SWITCH. 17 EFFECT SEND LEVEL Used to adjust the output level from EFFECT SEND JACK. The signal is selected by the effect switch. 15 -1 -3 -5 -7 -10 -15 POWER 18 EFFECT RETURN LEVEL Used to adjust the input level from the EFFECT RETURN JACK. [. . . ] The signal is selected by the effect switch. 15 -1 -3 -5 -7 -10 -15 POWER 18 EFFECT RETURN LEVEL Used to adjust the input level from the EFFECT RETURN JACK. This EFFECT RETURN can be used as the sub line input. L R EFFECT SEND 19 EFFECT CUE SWITCH Used to send the signal from EFFECT RETURN JACK to the monitor section for headphone monitoring. 17 MIN MAX RETURN 20 MASTER BALANCE VOLUME Adjusts the signal balance of left to the right side of the outputs from the OUTPUT jack on the rear panel. 18 MIN MAX 19 20 CUE OFF ON 21 22 MASTER LEVEL VOLUME Adjust the signal level output from the output jack on the rear panel. MASTER BAL SPLIT CUE SWITCH When this switch is ON, the master signal is always heard through the right earcup of the headphone. The CUE signal will be heard in the left earcup when that input is selected by the CUE SWITCH (5, 14). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VESTAX PT-X1000A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VESTAX PT-X1000A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.