User manual VESTAX PT-X1000A
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VESTAX PT-X1000A. We hope that this VESTAX PT-X1000A user guide will be useful to you.
Manual abstract: user guide VESTAX PT-X1000A
Detailed instructions for use are in the User's Guide.
[. . . ] Temperature Avoid use in hot, (over 35 )and cold, (below 5 ) locations. Keep the unit away from extreme direct heat such as direct sunlight, heating radiators, or closed vehicles. Power cord handling Connecting the power cord to other cords or joining cords together can cause fire and electric shock. [. . . ] Keep away from liquids Do not stand cans containing liquids on or near the equipment. If liquid enters equipment, disconnect the power cord from the power outlet immediately.
WARRANTY The warranty might vary from country to country. Each distributor has their own warranty system in accordance with the country or state regulations or laws. VESTAX observes the manufacturing country s regulations.
FEATURES
Three band isolator switch kills each frequency range completely in quick action. Pre / Post selectable AUX send switch enables various effect processing. The effect signal can be controlled by a dedicated return level control knob, the signal can be also monitored by headphone when "return" is selected by cue button. Three phono and 6 line inputs are provided to meet the new mixing style with various input source. The new PT-X1000A features removable flat panel that covers all screws etc. , That will impede fast mixing. New superior grade crossfader (CF-PCV) fitted to PT-X1000A enabling super smooth operation together with long life. Different signal routes can be selected this switch to different positions. P R E : The signal before the input fader (after the EQ) will be sent to AUX output. POST : The signal after the input and cross fader will be sent to AUX output. O F F : No signal will be sent to AUX output.
-16dB
+16dB
EFFECT
5 6
PRE
OFF
POST
CUE
OFF SIGNAL ON
6
CUE SWITCH
Used to send the signal from each program to monitor section for headphone monitoring.
7
LEVEL
10 9 8 7 6
INPUT FADER
Used to adjust the Input level of each program. Replace with the IF-175 when it is worn out.
8
CROSS FADER
When the Input level of PGM1 and PGM2 are properly set, PGM1 will be heard with the cross fader set to the left side. When the cross fader is set in the center, both programs will be heard. This is detachable fader for the ease of replacement with "CF-PCV" when it is worn out.
7
5 4 3 2 1 0
CF-PCV For PMC SERIES ( PMC05ProII, PMC06ProA, etc)
Insert the multi-cable connector
Set side switch to "PCV" position.
PMC CONNECTOR
Set switch to "PMC" position
4
HOW TO CHANGE THE FADER UNIT
HOW TO REMOVE THE TOP PANEL
1 Remove each fader knobs and 10 screws which
HOW TO CHANGE THE FADER UNIT
1 Remove the screws on the fader panel. 3 Carefully remove the multi-cable connector from
fix the top panel.
2 Remove the top panel.
Driver
fader unit.
4 Attach multi-cable connector
to new fader unit.
5 Position the fader unit
Driver
carefully and secure with screws.
Top panel
Main panel
MICROPHONE, SUB INPUT SECTION
LINE 4 IN
9
L
R
9
LINE INPUT JACK(LINE4)
Input connectors for line level equipment such as CD players, tape decks , DATs, or MDs etc.
MIC
10
MIC-1 MIC-2
10 11 12 13
MIC INPUT JACK(MIC1, 2)
Input jacks of mic1, mic2.
MIC-1
MIC LEVEL
Adjusts the input level from all of the microphone inputs.
11
MIN
MAX
MIC EQUALIZER(HI, LOW)
Adjusts the HI and LOW frequencies for all of the microphone input.
MIC-2
MIN
MAX
EFFECT SWITCH
Used when sending signal to the external effect processor connected to the effect SEND/RETURN.
EQ
HI
12
-16dB
+16dB
14
CUE SWITCH
Used to send the signal from the mic channel to the monitor section for headphone monitoring.
LO
-16dB +16dB
EFFECT
13 14
OFF
POST
CUE
OFF ON
5
MASTER SECTION 15 MASTER OUT LEVEL METER
The LED level meters indicate the signal level of the line out.
16
16
MASTER
+8 +5 +3 +1 0 +8 +5 +3 +1 0 -1 -3 -5 -7 -10 -15
POWER
CUE
CUE LEVEL METER
The LED level meters indicate the signal level of PGM input selected by CUE SWITCH.
17
EFFECT SEND LEVEL
Used to adjust the output level from EFFECT SEND JACK. The signal is selected by the effect switch.
15
-1 -3 -5 -7 -10 -15
POWER
18
EFFECT RETURN LEVEL
Used to adjust the input level from the EFFECT RETURN JACK. [. . . ] The signal is selected by the effect switch.
15
-1 -3 -5 -7 -10 -15
POWER
18
EFFECT RETURN LEVEL
Used to adjust the input level from the EFFECT RETURN JACK. This EFFECT RETURN can be used as the sub line input.
L
R
EFFECT
SEND
19
EFFECT CUE SWITCH
Used to send the signal from EFFECT RETURN JACK to the monitor section for headphone monitoring.
17
MIN MAX
RETURN
20
MASTER BALANCE VOLUME
Adjusts the signal balance of left to the right side of the outputs from the OUTPUT jack on the rear panel.
18
MIN MAX
19 20
CUE
OFF ON
21
22
MASTER LEVEL VOLUME
Adjust the signal level output from the output jack on the rear panel.
MASTER
BAL
SPLIT CUE SWITCH
When this switch is ON, the master signal is always heard through the right earcup of the headphone. The CUE signal will be heard in the left earcup when that input is selected by the CUE SWITCH (5, 14). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VESTAX PT-X1000A
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VESTAX PT-X1000A will begin.