User manual VESTAX PDT-5000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VESTAX PDT-5000. We hope that this VESTAX PDT-5000 user guide will be useful to you.


VESTAX PDT-5000 : Download the complete user guide (651 Ko)

Manual abstract: user guide VESTAX PDT-5000

Detailed instructions for use are in the User's Guide.

[. . . ] Temperature Avoid use in hot, (over 35 )and cold, (below 5 ) locations. Keep the unit away from extreme direct heat such as direct sunlight, heating radiators, or closed vehicles. Power cord handling Connecting the power cord to other cords or joining cords together can cause fire and electric shock. Handle only the plug or connector and do not perform these operations with wet hands. [. . . ] If liquid enters equipment, disconnect the power cord from the power outlet immediately. WARRANTY The warranty might vary from country to country. Each distributor has their own warranty system in accordance with the country or state regulations or laws. VESTAX observes the manufacturing country s regulations. F E AT U R E S Three band isolator switch kills each frequency range completely in quick action. Pre / Post selectable AUX send switch enables various effect processing. The effect signal can be controlled by a dedicated return level control knob, the signal can be also monitored by headphone when "return" is selected by cue button. Three phono and 6 line inputs are provided to meet the new mixing style with various input source. User replaceable 60 m/m input faders and 45 m/m cross fader make "on sight service" very easy. Optional input rotary volume can be replaced with the fader for "House" application. This allows DJs to use hand carried DAT or MD player mixing with installed equipment. TOP PANEL PROGRAM INPUT SECTION PRO FESSIONAL MIXING CONTROLLER PDT-5000 MASTER +8 +8 +5 +3 +1 0 -1 -3 -5 -7 -10 -15 POWER LINE 4 IN INPUT L R PHONO 1 PGM 1 INPUT LINE 2 PHONO 2 SUB INPUT LINE 4 PHONO 3 PGM 2 LINE 6 CUE +5 +3 MIC TRIM LINE 1 LINE 3 LINE 5 +1 0 MASTER SECTION TRIM TRIM -1 -3 MIC-1 MIC-1 MIC-2 MIN MAX MIN MAX MIN MAX -5 -7 -10 -15 POWER MICROPHONE AND SUB INPUT SECTION BAL BAL BAL MIN MAX L R L R L R MIC-2 EQ HI EQ HI EQ HI L R EFFECT SEND MIN MAX -16dB +16dB -16dB +16dB -16dB +16dB EQ HI MID MID MID MIN MAX RETURN -16dB +16dB -12dB +12dB -12dB +12dB -12dB +12dB LOW LOW LOW LOW MIN MAX CUE -16dB +16dB -16dB +16dB -16dB +16dB -16dB +16dB EFFECT OFF POST EFFECT PRE OFF POST EFFECT PRE OFF POST EFFECT PRE OFF POST OFF ON MASTER BAL CUE OFF ON CUE OFF SIGNAL ON CUE OFF SIGNAL ON CUE OFF SIGNAL ON L R LEVEL 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 MIN MAX MONITOR SPLIT CUE ON OFF PHONES LEVEL MIN MAX PHONES IN PGM1 ISOLATOR PGM2 ISOLATOR LOW MID HI 1 2 LOW MID HI ISOLATOR SECTION PHONES IN PROGRAM INPUT SECTION PGM 1 INPUT PHONO 1 LINE 2 PROGRAM INPUT SECTION 1. INPUT SELECTOR Used to select input (2 line or 1 phono) to be sent to each PGM channel. CUE SWITCH +3 +3 Used to send the signal from the mic channel to the +1 +1 monitor section for headphone monitoring. 0 0 -1 -1 -3 -5 -7 -10 -15 POWER 9 L R MIC 10 MIC-1 MIC-1 MIC-2 11 MIN MAX MIC-2 MASTER SECTION MIN MAX -3 -5 -7 -10 -15 POWER 16 EQ HI 12 -16dB +16dB LOW -16dB +16dB EFFECT 13 OFF POST CUE 14 OFF ON 15. MASTER OUT LEVEL METER The LED level meters indicate the signal level of the line out. CUE LEVEL METER The LED level meters indicate the signal level of PGM input selected by CUE SWITCH. EFFECT SEND LEVEL Used to adjust the output level from EFFECT SEND JACK. EFFECT RETURN LEVEL Used to adjust the input level from the EFFECT RETURN JACK. EFFECT CUE SWITCH Used to send the signal from EFFECT RETURN JACK to the monitor section for headphone monitoring. MASTER BALANCE VOLUME Adjusts the signal balance of left to the right side of the outputs from the OUTPUT jack on the rear panel. MASTER LEVEL VOLUME Adjust the signal level output from the output jack on the rear panel. SPLIT CUE SWITCH When this switch is ON, the master signal is always heard through the right earcup of the headphone. [. . . ] The CUE signal will be heard in the left earcup when that input is selected by the CUE SWITCH (5, 14). This enables both programs to be monitored simultaneously, thus assisting in beat mixing. HEAD PHONE JACK Use this jack to connect the headphones the impedance 8ohm to 600ohm can be used, 150ohm is recommended. L R EFFECT SEND 15 17 MIN MAX RETURN 18 MIN MAX CUE OFF ON 19 MASTER BAL 20 L R LEVEL 21 MIN MAX MONITOR SPLIT CUE ON OFF 22 23 MAX PHONES LEVEL MIN PHONES IN 24 ISOLATOR SECTION 25, HI SWITCH Allows cutting off the sound of treble range. Can be useful for cutting off the sound of the cymbals or high hats for example. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VESTAX PDT-5000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VESTAX PDT-5000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.