User manual VESTAX PDT-5000
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VESTAX PDT-5000. We hope that this VESTAX PDT-5000 user guide will be useful to you.
Manual abstract: user guide VESTAX PDT-5000
Detailed instructions for use are in the User's Guide.
[. . . ] Temperature Avoid use in hot, (over 35 )and cold, (below 5 ) locations. Keep the unit away from extreme direct heat such as direct sunlight, heating radiators, or closed vehicles. Power cord handling Connecting the power cord to other cords or joining cords together can cause fire and electric shock. Handle only the plug or connector and do not perform these operations with wet hands. [. . . ] If liquid enters equipment, disconnect the power cord from the power outlet immediately.
WARRANTY The warranty might vary from country to country. Each distributor has their own warranty system in accordance with the country or state regulations or laws. VESTAX observes the manufacturing country s regulations.
F E AT U R E S
Three band isolator switch kills each frequency range completely in quick action. Pre / Post selectable AUX send switch enables various effect processing. The effect signal can be controlled by a dedicated return level control knob, the signal can be also monitored by headphone when "return" is selected by cue button. Three phono and 6 line inputs are provided to meet the new mixing style with various input source. User replaceable 60 m/m input faders and 45 m/m cross fader make "on sight service" very easy. Optional input rotary volume can be replaced with the fader for "House" application. This allows DJs to use hand carried DAT or MD player mixing with installed equipment.
TOP PANEL
PROGRAM INPUT SECTION
PRO FESSIONAL MIXING CONTROLLER
PDT-5000
MASTER
+8 +8 +5 +3 +1 0 -1 -3 -5 -7 -10 -15
POWER
LINE 4 IN
INPUT L R
PHONO 1
PGM 1
INPUT
LINE 2 PHONO 2
SUB
INPUT
LINE 4 PHONO 3
PGM 2
LINE 6
CUE
+5 +3
MIC
TRIM
LINE 1
LINE 3
LINE 5
+1 0
MASTER SECTION
TRIM
TRIM
-1 -3
MIC-1 MIC-1
MIC-2
MIN MAX MIN MAX MIN MAX
-5 -7 -10 -15
POWER
MICROPHONE AND SUB INPUT SECTION
BAL
BAL
BAL
MIN
MAX
L
R
L
R
L
R
MIC-2
EQ HI
EQ HI
EQ HI
L
R
EFFECT
SEND
MIN MAX -16dB +16dB -16dB +16dB -16dB +16dB
EQ HI
MID
MID
MID
MIN MAX
RETURN
-16dB +16dB -12dB +12dB -12dB +12dB -12dB +12dB
LOW
LOW
LOW
LOW
MIN MAX
CUE
-16dB +16dB -16dB +16dB -16dB +16dB -16dB +16dB
EFFECT
OFF POST
EFFECT
PRE OFF POST
EFFECT
PRE OFF POST
EFFECT
PRE OFF POST
OFF
ON
MASTER
BAL
CUE
OFF ON
CUE
OFF SIGNAL ON
CUE
OFF SIGNAL ON
CUE
OFF SIGNAL ON
L R
LEVEL
10 9 8 7 6 5 4 3 2 1 0
10 9 8 7 6 5 4 3 2 1 0
10 9 8 7 6 5 4 3 2 1 0
MIN
MAX
MONITOR
SPLIT CUE
ON OFF
PHONES LEVEL
MIN
MAX
PHONES IN
PGM1 ISOLATOR
PGM2 ISOLATOR
LOW
MID
HI
1
2
LOW
MID
HI
ISOLATOR SECTION
PHONES IN
PROGRAM INPUT SECTION
PGM 1
INPUT
PHONO 1 LINE 2
PROGRAM INPUT SECTION
1. INPUT SELECTOR Used to select input (2 line or 1 phono) to be sent to each PGM channel. CUE SWITCH +3 +3 Used to send the signal from the mic channel to the +1 +1 monitor section for headphone monitoring. 0 0
-1 -1 -3 -5 -7 -10 -15
POWER
9
L
R
MIC
10
MIC-1 MIC-1 MIC-2
11
MIN
MAX
MIC-2
MASTER SECTION
MIN MAX
-3 -5 -7 -10 -15
POWER
16
EQ HI
12
-16dB
+16dB
LOW
-16dB
+16dB
EFFECT
13
OFF POST
CUE
14
OFF
ON
15. MASTER OUT LEVEL METER The LED level meters indicate the signal level of the line out. CUE LEVEL METER The LED level meters indicate the signal level of PGM input selected by CUE SWITCH. EFFECT SEND LEVEL Used to adjust the output level from EFFECT SEND JACK. EFFECT RETURN LEVEL Used to adjust the input level from the EFFECT RETURN JACK. EFFECT CUE SWITCH Used to send the signal from EFFECT RETURN JACK to the monitor section for headphone monitoring. MASTER BALANCE VOLUME Adjusts the signal balance of left to the right side of the outputs from the OUTPUT jack on the rear panel. MASTER LEVEL VOLUME Adjust the signal level output from the output jack on the rear panel. SPLIT CUE SWITCH When this switch is ON, the master signal is always heard through the right earcup of the headphone. [. . . ] The CUE signal will be heard in the left earcup when that input is selected by the CUE SWITCH (5, 14). This enables both programs to be monitored simultaneously, thus assisting in beat mixing. HEAD PHONE JACK Use this jack to connect the headphones the impedance 8ohm to 600ohm can be used, 150ohm is recommended.
L
R
EFFECT
SEND
15 17
MIN
MAX
RETURN
18
MIN MAX
CUE
OFF ON
19
MASTER
BAL
20
L R
LEVEL
21
MIN MAX
MONITOR
SPLIT CUE
ON OFF
22 23
MAX
PHONES LEVEL
MIN
PHONES IN
24
ISOLATOR SECTION
25, HI SWITCH Allows cutting off the sound of treble range. Can be useful for cutting off the sound of the cymbals or high hats for example. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VESTAX PDT-5000
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VESTAX PDT-5000 will begin.