User manual VESTAX PCV-275
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VESTAX PCV-275. We hope that this VESTAX PCV-275 user guide will be useful to you.
Manual abstract: user guide VESTAX PCV-275
Detailed instructions for use are in the User's Guide.
[. . . ] Always disconnect all equipment from the main supply when disconnecting or reconnecting signal leads. Make sure that the power switch is off when connecting the power cord. [. . . ] This allows DJs to use hand carried DAT or MD player mixing with installed equipment.
1
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTl0N TO REDUCE THE RlSK OF ELECTRlC SHOCK DO NOT REMOVE COVER OR BACK NO USER-SERVICEABLE PARTS INSIDE REFER SERVlCING T0 QUALIFIED SERVlCE PERSONNEL The lighting flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product's enclosure that may be of sufficient magnitude to consitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance
WARNING
T0 REDUCE THE RISK 0F FIRE 0R ELECTRlC SHOCK THIS APPLIANCE T0 RAIN 0R M0ISTURE CAUTION DO NOT EXPOSE
TO PREVENT ELECTRIC SHOCK, MATCH BLADE OF PLUG TO WIDE SLOT FULLY INSERT
ATTENTION
P0UR EVITER LES CH0CS ELECTRIQUES INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESP0NDANTE DE LA PRISE ET P0USSER JUSQU AU F0ND
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
WARNING : When using electric products, basic precaution should always be followed, including the following :
1. Do not use this product near water - for example, near a from the outlet when left unused for a long period of time. Care should be taken so that objects do not fall and liquids are bathtub, washbowl, kitchen sink, in a wet basement, or near a swimming pool, or the like. The product should be serviced by qualified service personnel recommended by the manufacturer. The power - supply cord or the plug has been damaged ; and headphone or speakers, may be capable of producing B. Objects have fallen, or liquid has been spilled into the sound levels that could cause permanent hearing loss. Do not product ; or operate for a long period of time at a high volume level or at a C. The product has been exposed to rain ; or level that is uncomfortable. Do not attempt to service the product beyond that described in with its proper ventilation. The product should be located away from heat sources such as be referred to qualified service personnel. The product should be connected to a power supply only of the type described in operating instructions or as marked on the product.
2
FUNCTIONS
TOP PANEL
MICROPHONE AND SUBINPUT SECTION
PROGRAM INPUT SECTION
MASTER SECTION
LINE 4 IN
L R
PGM 1
INPUT
PHONO 1 LINE 2
SUB
INPUT
PHONO 2 LINE 4
PGM 2
INPUT
PHONO 3 LINE 6
MASTER
+8 +5 +8 +5 +3 +1 0 -1 -3 -5 -7 -10 -15
POWER
CUE
MIC
TRIM
+3 LINE 1 LINE 3 LINE 5 +1 0
TRIM
TRIM
-1 -3
MIC-1
MIC-2
MIN MAX MIN MAX MIN MAX
-5 -7 -10 -15
POWER
MIC-1
BAL
BAL
BAL
MIN
MAX
L
R
L
R
L
R
MIC-2
EQ
HI
EQ
HI
EQ
HI
L
R
EFFECT
SEND
MIN MAX -16dB +16dB -16dB +16dB -16dB +16dB
EQ
HI
MID
MID
MID
MIN MAX
RETURN
-16dB +16dB -12dB +12dB -12dB +12dB -12dB +12dB
LO LO
LO
LO
MIN MAX
CUE
-16dB +16dB -16dB +16dB -16dB +16dB -16dB +16dB
OFF
ON
EFFECT
OFF POST
EFFECT
EFFECT
EFFECT
MASTER
PRE OFF POST PRE OFF POST PRE OFF POST
BAL
CUE
OFF ON
CUE
OFF SIGNAL ON
CUE
OFF SIGNAL ON
CUE
OFF SIGNAL ON
L R
LEVEL
LEVEL
10 9 8 7 6 5 4 10 9 8 7 6 5 4 3 2 1 0
LEVEL
10 9 8 7 6 5 4 3 2 1 0
LEVEL
MIN MAX
MONITOR
SPLIT CUE
ON OFF
PHONES LEVEL
ISOLATOR SECTION
3 2 1 0
MIN
MAX
PHONES IN
PGM1 ISOLATOR
PGM2 ISOLATOR
LO
MID
HI
1
2
LO
MID
HI
PHONES IN
8
3
PROGRAM INPUT SECTION
PGM 1
INPUT
PHONO 1 LINE 2
1 2
INPUT SELECTOR
Used to select input (2 line or 1 phono) to be sent to each PGM channel.
1 2
MIN
TRIM CONTROL
Adjusts the Input level of each channel. adjust TRIM so that the INPUT LEVEL METER shows about 0dB.
LINE 1
3
MAX
BALANCE CONTROL
Adjusts the stereo balance for each PGM channel. [. . . ] The signal is selected by the effect switch.
15
-1 -3 -5 -7 -10 -15
POWER
18
EFFECT RETURN LEVEL
Used to adjust the input level from the EFFECT RETURN JACK. This EFFECT RETURN can be used as the sub line input.
L
R
EFFECT
SEND
19
EFFECT CUE SWITCH
Used to send the signal from EFFECT RETURN JACK to the monitor section for headphone monitoring.
17
MIN MAX
RETURN
20
MASTER BALANCE VOLUME
Adjusts the signal balance of left to the right side of the outputs from the OUTPUT jack on the rear panel.
18
MIN MAX
19 20
CUE
OFF ON
21
22
MASTER LEVEL VOLUME
Adjust the signal level output from the output jack on the rear panel.
MASTER
BAL
SPLIT CUE SWITCH
When this switch is ON, the master signal is always heard through the right earcup of the headphone. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VESTAX PCV-275
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VESTAX PCV-275 will begin.