User manual VESTAX GE-31A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VESTAX GE-31A. We hope that this VESTAX GE-31A user guide will be useful to you.


VESTAX GE-31A : Download the complete user guide (181 Ko)

Manual abstract: user guide VESTAX GE-31A

Detailed instructions for use are in the User's Guide.

[. . . ] Such as 3 band isolators & great high, low and notch filters on each PGM, a master out isolator section with anti phase and a matrix input control so you can mix in and out of inputs quickly and easily. Regardless of your skill level you will find the CX enjoyable and easy to use because of its layout and great features, but you will fall in love with it because of its high quality components and design. Matrix Input Assign The matrix input assign on the GE-31A is an innovative and useful feature that allows you to select or route any input source on/to any channel. On the GE-31A you are able to route inputs connected on one channel to any other channel. [. . . ] Pressing this switch activates the high pass filter and when on the indicator LED will illuminate. The cut off frequencies for this filter can be adjusted by the SWEEP volume rotary dial !1. If this switch is pressed simultaneously with the Low Pass Filter switch the resulting effect is a Notch Pass Filter. !0 LOW PASS FILTER SWITCH On each PGM is a LOW pass filter switch. When on the indicator LED will be illuminated and this filter will remove sound frequencies below the cut off point. The cut off point can be adjusted by using the SWEEP volume rotary dial !1. If this switch is pressed simultaneously with the High Pass Filter switch the resulting effect is a Notch Pass Filter. !1 SWEEP VOLUME This rotary dial is used to adjust the filter cut off points on each PGM. A rotation to the left will result in a movement away from the High frequencies towards the Low frequencies. Vice versa a movement to the right will result in a movement away from the Low frequencies towards the High frequencies. !2 C. F. ASSIGN SWITCH q PHONO / LINE SELECTOR Selects the signal (PHONO or LINE) to be sent to each INPUT. Connect the output of a CD player, MD player, and tape deck to the line input. Assigns the signals from each of the PGM channels to either side of the crossfader or to MASRER OUT. *For best sound quality Vestax recommends using Headphones with 150ohm impedance. $5 MIC MONITOR IN/OUT SWITCH Select whether the signal connected to MAIN/SUB MIC is mixed with the signal outputted from MASTER OUT1/2. $6 REC OUT JACK Connects to the input jack of a recording device IE, tape recorder, MD, DAT, etc. The output level of this jack is fixed and does not change with the MASTER LEVEL. HOW TO CHANGE THE FADER UNIT INPUT FADER Change to "IF-500" q Remove the fader knob. (See fig-a) w Remove the 4 screws which fix the input fader panel to the mixer. (See fig-c) r Remove the input fader, and carefully remove the multi-cable connecter from the fader unit. (See fig-d) t Replace the fader unit making sure to that the connector wires are securely fastened before carefully positioning the fader unit and affixing with screws. MASTER SECTION @0 BOOTH MONITOR EQ VOLUME Adjusts the HI/MID/LOW frequencies for the BOOTH OUT. @1 BOOTH MONITOR LEVEL VOLUME Adjusts the output level of BOOTH MONITOR. @2 BOOTH MONITOR MUTE SWITCH This switch mute the signal being sent to the BOOTH OUT. @3 ANTI PHASE ON / OFF SWITCH This switch is used to activate an antiphase effect on the Master Isolator Section. Essentially, an antiphase flips the isolator curve upside down on both the low and mid frequency ranges, which thereby creates a reverb type effect on the signal being outputted. @4 MASTER ISOLATOR HI This rotary dial section can be used to isolate the Hi frequencies on any MASTER SECTION input signal. @5 MASTER ISOLATOR MID This rotary dial section can be used to isolate Mid frequencies on any MASTER SECTION input signal. @6 MASTER ISOLATOR LOW This rotary dial section can be used to boost the Low frequencies on any MASTER SECTION input signal. @7 ISOLATOR ON / OFF SWITCH This switch is used to turn the Master Isolator Volume Section either on or off. When set to the "OFF" position the full range of input signal being sent to the MASTER section will be heard regardless of the position of the Master Isolator Volume rotary dials. @8 CROSS FADER Mixes the signals assigned by the CROSSFADER ASSIGN SWITCHES to either side of the crossfader. When the crossfader is set in the center position, both the left and right signals will be heard. This fader is user replaceable and may be changed easily by following this user guide's instructions carefully. *Replace this fader with a Vestax CF-50 replacement inputfader. !5 MASTER LEVEL VOLUME Adjusts the signal level outputs from MASTER OUT1/2 JACKS $7 on the rear panel. !6 MASTER CUE SWITCH Used to send the signal from MASTER OUT1/2 to the monitor section for headphone monitoring. When switch is on, an indicator lights up. !7 CF CURVE VOLUME djusts the crossfader curve. [. . . ] Accessories-Do not place this product on an unstable cart, stand, tripod, or table. The product may fall, causing serious injury to a child or adult, and serious damage to the appliance. stand, tripod, bracket, or table recommended by the manufacturer, or sold with product. Any mounting of the appliance should follow the manufacturer's instructions, and sholud use a mounting accessory recommended by the manufacturer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VESTAX GE-31A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VESTAX GE-31A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.