User manual VESTAX CDX-25

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VESTAX CDX-25. We hope that this VESTAX CDX-25 user guide will be useful to you.


VESTAX CDX-25 : Download the complete user guide (509 Ko)

Manual abstract: user guide VESTAX CDX-25

Detailed instructions for use are in the User's Guide.

[. . . ] Å@ Stutter play can be performed with this key. ÅiP. 11Åj Å@ Selects the CUE key's operation mode. ÅiP. 11Åj NOTE Åú If the disc is recorded with multi session , the CDX-25 can read the files in first session area only. ÅúMP3 playback function does not support following functions. Å@CUE and CUE 1-3 Å@Loop play Å@Search Å@Reverse play Å@Track memory Å@Total remain time display Å@Remain time display Å@Time address bar display - 1. A Å@ Å@ NOTE Å@ These keys cannot be used when direct mode (Preset menu: page 23) is off and a disc is being played back. 2. [. . . ] ÅSearch ÅPitch Bend ÅScratch ÅBrake time ÅKey control ÅPreset menu ÅEffect parameters ÅSampler tempo/level ÅProgram edit ÅTrack memory number select (SHIFT) (PGM EDIT) Insert program 1. Enter the program edit mode by pressing and holding the SHIFT key and then pressing the PLAY MODE/PGM EDIT key. / ENTER TIME PLAY MODE 16. LCD Å@ Displays visual feedback for CDX-25 functions Å@ this key is pushed once, it will be in a sampling If standby state (blink), and a sampling will be started(lighting) if it pushes on the next . A sampling will be stopped if it pushes again (lights out). (p. 18) Sampling time is for 8 seconds at the maximum. ÅB (SHIFT) (PGM EDIT) Sampler output level SAMPLER REC Å@ While pushing the PLAY key then using the Jog wheel adjusts the sampler output level. The sampler output level can be set from 0 (mute) to 100 (default level). LOOP ON / OFF PLAY 3-7. Track Memory / Recall Å@ CDX-25 can memorize the various The Å@ playback settings of current selected tracks up to100 tracks of memory. Track Memory 1. Enter the track memory mode by pressing and holding the SHIFT key then pressing the TRK MEM key. / ENTER TIME CUE-SET / INS Å@ (SHIFT) (TRK MEMO) 4. At this time, if there is stored memory in the selected memory number, indication is displayedÅ@ Å@ Å@ the LCD. Å@ Å@ in Å@ Pressing the ENTER key overwrites the current track data. LCD shows the lowest empty memory number. Memory data WARNING;SHOCK HAZARD-DO NOT OPEN. AVIS;RISQUE DE CHOC ELELCTRIQUE -NE PAS OUVRIR. (SHIFT) DC 8V RISK OF ELECTRIC SHOCK. Å@ ÅE When the unit is paused and the CUE-PLY indicator in the LCD doesn't light, pressing the SET key then pressing the CUE 1-3 key flashes the pressed CUE 1-3 key three times then lights. ÅE three seconds after storing the cue point, you cannot store another cue point. For NOTE PLAY Sampler Pitch Control Å@ While pushing the Loop key the Jog wheel changes the play back pitch of the sampler. The pitch control range is +/-32% in 0. 1% steps. SAMPLER REC Stutter play with the CUE 1-3 keys LOOP ON / OFF Å@ Å@ When the unit is paused at the cue 1-3 point, the unit will play when the appropriate CUE 1-3 key is pressed, and enter pause mode when CUE 1-3 is released. Å@ the PLAY key is pressed during CUE playback, the unit will go into normal play mode. CUE-PLAY Å@ Å@ CDX-25 has a flash start function that can be used The with the CUE 1-3 keys. When the flash start function is activated (when the CUE-PLY indicator in the LCD lights), pressing the CUE 1-3 key enables flash start. CUE-SET / INS CUE 1 Effect level setting Å@ CUE 2 CUE 3 (TRK MEMO) NOTE Å@ When the CUE-PLY indicator in the LCD doesn' t light, the unit is back in cue mode. In this mode, pressing the CUE 1-3 key locates the stored cue point then the unit pauses. Å@ When an effect is activated, pressing and holding the SHIFT key then pressing the activated effect key enters the effect level setting mode. The effect level parameter is shown in the parameter display. TIME / ENTER EFFECT FLANGE FILTER DELAY (SHIFT) Å@ LOOP RELOOP /EXIT FLANGER LOOP START Å@ Pressing the FLANGE key activates the Flanger effect. If the RELOOP key is pushed during reverse play, reverse will be canÅú celed and it will usually become loop play. LOOP START LOOP END 17 3-3. Brake LOOP RELOOP /EXIT BRAKE Å@ Å@ Brake function simulates the braking audio just like turning off the analog turntable. [. . . ] Tapped BPM is shown in the LCD parameter display and the TAP LED blinks in tempo. If the TEMPO slider is moved, the BPM will be changed automatically. TAP Å@ Pressing and holding the TAP key for more than 1. 5 seconds erases the tapped BPM value. Å@ Pressing and holding the TAP key then moving the Jog wheel (within 1. 5 seconds) adjusts the BPM manually. Å@ The CDX-25 features up to +/-10% key control. When tempo control range is set to 0%, or 100%, the key control function does not work. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VESTAX CDX-25




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VESTAX CDX-25 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.