User manual VAISALA QMD202 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA QMD202. We hope that this VAISALA QMD202 user guide will be useful to you.


VAISALA QMD202 DATASHEET: Download the complete user guide (241 Ko)

Manual abstract: user guide VAISALA QMD202DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. vaisala. com Vaisala Fixed Display QMD202 Features/Benefits Local User Interface for MAWS The HydroMet system can be equipped with the QMD202 display and keyboard unit at the installation site where the operator needs to see the measurement values locally and insert observations or reference data into the system. [. . . ] The full display size expressed in characters is 20 x 6 (width x height). The contents, format, and updating intervals of these reports are user-configurable. The update interval can be anything between 1 second and 24 hours. Installation Outside the Enclosure The QMD202 unit can also be installed outside the MAWS enclosure via the RS-232 or the full-duplex RS-485 connection. The RS-485 connection together with a DSI485 module installed into the MAWS data logger allows installations up to 1000 meters from the logger. Technical data Electrical Input voltage Vin RS232/485 Mechanical 8 . . . 18 VDC 3. 3 and 5. 0 VDC powered from the MAWS data logger Dimensions Weight Mounting Enclosure material LCD Display Size (width x height) 127 x 95 x 29 mm 230 g NS35 DIN rail foot Aluminium 20 x 6 characters SPI Power consumption SPI mode, backlight OFF 20 mW SPI mode, backlight ON 85 mW RS485 mode, backlight OFF 96 mW @ 12 V RS485 mode, backlight ON 252 mW @ 12 V RS232 mode, backlight OFF 132 mW @ 12 V RS232 mode, backlight ON 276 mW @ 12 V Interface RS-232 / RS-485 / SPI Connector for RS-232, RS-485 and power supply 8-pin M12 RS-232 1200, 2400, 4800, 9600 bps (default 9600 bps) RS-485 Full duplex, non-isolated, 1200, 2400, 4800, 9600 bps (default 9600 bps) SPI Connected to and powered by the MAWS data logger via a 10-wire flat cable Communication distances RS-232 30 m RS-485 1000 m SPI Inside the MAWS enclosure Environmental Operating temperature Storage temperature CE Compliant Vibration -25 . . . +60 °C IEC(EN)-61326-1, For use in industrial locations IEC 60068-2-6, level 2 g Example of QMD display. For more information, visit www. vaisala. com or contact us at sales@vaisala. com Ref. [. . . ] All specifications -- technical included -- are subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA QMD202




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA QMD202 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.