User manual VAISALA PTU200MIK1
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA PTU200MIK1. We hope that this VAISALA PTU200MIK1 user guide will be useful to you.
Manual abstract: user guide VAISALA PTU200MIK1
Detailed instructions for use are in the User's Guide.
[. . . ] USER'S GUIDE
Outdoor Mounting Kit PTU200MIK1
M210226EN-A
PUBLISHED BY Vaisala Oyj P. O. Box 26 FIN-00421 Helsinki Finland Phone (int. ): +358 9 8949 1 Fax: +358 9 8949 2227
Visit our Internet pages at http://www. vaisala. com/ © Vaisala 2006 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice.
Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. [. . . ] Two different installations.
A tripod stand PTU200TRIPOD is for use with the outdoor mounting kit PTU200MIK1 Due to its collapsible structure, it is easy to transfer, which ensures quick system set up even for temporary installations. PTU200TRIPOD includes an adjustable tripod stand with a carrying strap and 650 mm pole (Ø 60 mm).
VAISALA __________________________________________________________________________ 3
USER'S GUIDE_______________________________________________________________________
CHAPTER 3
PTU200MIK1 INSTALLATION
Plastic bag (2 pcs. ) include: Clamp for pole mounting Plastic fitting ring Hex bolt (2 pcs. ) M8x40 DIN 931 Washer (2 pcs. ) A 8. 4 DIN 125 Hex nut (2 pcs. ) M8 DIN 934 Allen screw (2 pcs. ) M6x12 DIN 912
Attach the clamp with the machined side up to the T-profile with the two Allen screws. Pole diameter: - Clamps with the fitting ring 2"(-1/8") - Clamps without the fitting ring 60 (-5 mm).
Plastic bag includes: Cover plate Slot headed screw (2 pcs. ) M4x6 DIN 84 Washer (2 pcs. ) A 4. 3 DIN 125 Place the cover plate on the transmitter box and fasten it with the two slot headed screws.
4 ___________________________________________________________________ NOVEMBER 2001
CHAPTER 3___________________________________________________ PTU200MIK1 INSTALLATION
Installation when static pressure head is on the right side
Installation plate
Radiation shield
1. Mount the support arm on the upper clamp. Use the plate, two hex bolts and washers for the attachement as shown in figure.
2. Fasten the installation plate onto the support arm. Fasten it to the plate with the slot headed screws (M5x16 DIN84, provided)
Boom adapter
4. Attach the support arms and fasten with two screws.
VAISALA __________________________________________________________________________ 5
USER'S GUIDE_______________________________________________________________________
7. Attach the pressure hose end to the threaded nipple of the pressure head. 9. Fasten the static pressure head to the end of the support arm (and installation plate) by using the two screws.
6. Thread the pressure hose through the support arm.
10. Connect the free end of the pressure hose to the hose coupling on backside of the transmitter box. This is to prevent the condense water block the tube as it freezes.
6 ___________________________________________________________________ NOVEMBER 2001
CHAPTER 3___________________________________________________ PTU200MIK1 INSTALLATION
Installation when static pressure head is on the left side
Boom adapter 3. Mount the support arm on the upper clamp. Fasten it by using the plate, two hex bolts and washers for the attachement as shown in the figure. Mount the static pressure head and thread the pressure hose as instructed on page 6.
6. Connect the free end of the pressure hose to the hose coupling on backside of the transmitter box. This is to prevent the condense water block the tube as it freezes.
VAISALA __________________________________________________________________________ 7
USER'S GUIDE_______________________________________________________________________
Connections in the transmitter box
1. Mount the PTU200 transmitter on the back plate of the transmitter box and attach it with the four Allen screws. Allen key for opening the transmitter
3. Thread the cables through the hole in the bottom of the box. (The diameter of the bottom hole is 35 mm) 4. Thread the cables through the different parts of the gasket fitting in the order shown in the figure. There are two alternative rubber sealings, one for the cables of 4 and 6 mm and one for the cables of 6 and 6 mm. [. . . ] Certain meteorological standards define the altitude for the pressure measurement. As the transmitter is installed into the protective box, the distance of the pressure transducer from the bottom of the transmitter box is 192 ±5 mm.
VAISALA _________________________________________________________________________ 11
USER'S GUIDE_______________________________________________________________________
CHAPTER 5
DIMENSIONS in mm (in inches)
Static pressure head on the left side
371 14. 6024
1136 44. 7244
353 13. 8855
232 9. 1142
146 5. 748
564 22. 185 154 6. 0447
420 16. 5354
ø
ø 200 7. 874
12 __________________________________________________________________ NOVEMBER 2001
ø
36
22
51
60
2.
2
CHAPTER 5__________________________________________________ DIMENSIONS IN MM (IN INCHES)
Static pressure head on the right side
353 13. 8855
232 9. 1142
1134 44. 626
371 14. 6024
146 5. 748
420 16. 5354
ø 60 2. 36 22
534 21. 0039
51
2
154 6. 0447
VAISALA _________________________________________________________________________ 13
ø 200 7. 874
ø
www. vaisala. com [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA PTU200MIK1
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA PTU200MIK1 will begin.