User manual VAISALA HMW70Y

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA HMW70Y. We hope that this VAISALA HMW70Y user guide will be useful to you.


VAISALA HMW70Y : Download the complete user guide (126 Ko)

Manual abstract: user guide VAISALA HMW70Y

Detailed instructions for use are in the User's Guide.

[. . . ] All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale. U304en-1. 1 HMW70U/Y Transmitters Operating Manual Contents 1. PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 TO BE NOTED WHEN MEASURING HUMIDITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 8 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6. 4. 1 Emissions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6. 4. 2 Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 GUARANTEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2000-08-23 i HMW70U/Y Transmitters Operating Manual U304en-1. 1 This page intentionally left blank. ii 2000-08-23 U304en-1. 1 HMW70U/Y Transmitters Operating Manual 1. PRODUCT DESCRIPTION The HMW70 transmitters are wall mounted transmitters for the measurement of humidity (HMW70U) and for the measurement of humidity and temperature (HMW70Y). One point calibration is easily performed with the HMI41 indicator and the calibration cable 19116ZZ. Both transmitter types incorporate the HUMICAP®180 humidity sensor which uses an operating principle based on changes in the capacitance of a thin polymer film as it absorbs water molecules. The HMW70Y transmitters measure temperature with the reliable Pt 1000 sensor. 2000-08-23 1 HMW70U/Y Transmitters Operating Manual U304en-1. 1 2. TO BE NOTED WHEN MEASURING HUMIDITY In the measurement of humidity and especially in calibration, it is essential that the temperature equilibrium is reached. Even a slight difference in the temperature between the measured object and the sensor causes an error. For example, at +20 °C (+ 68 °F) and 50 %RH, a temperature difference of +1 °C between the measured object and the sensor causes an error of +3 %RH. The error is at its greatest when the temperature of the sensor differs from that of the surroundings and the humidity is high. A few degrees' difference in temperature may cause water to condense on sensor surface. Efficient ventilation accelerates evaporation whereas in an unventilated space, it may take hours. The HUMICAP®180 sensor returns to its normal functioning as soon as water has evaporated. Any contaminated water condensing on the sensor may shorten its life span and change the calibration. 10 9 8 7 dRH (%RH) 6 5 4 3 2 1 0 -40 -20 0 20 40 60 80 100 Temperature (°C) Figure 2. 1 Measurement error at 100 %RH when the temperature difference between the ambient and the sensor is 1 °C 2 2000-08-23 U304en-1. 1 HMW70U/Y Transmitters Operating Manual 3. 3. 1 INSTALLATION Selecting the place of installation Select a place that gives a true picture of the environment or process and is as clean as possible. A rapid air flow is recommended as it ensures the same temperature for the ambient air and the sensor head. Install the transmitter in a place where no cold or hot spot can develop. [. . . ] Recalibrate the transmitter. 2000-08-23 7 HMW70U/Y Transmitters Operating Manual U304en-1. 1 6. 6. 1 TECHNICAL DATA Relative humidity Measurement range 0. . . 95 %RH (output signal corresponds to 0. . . 100 %RH) Accuracy at +20 °C: %RH 3 2 1 0 -1 -2 -3 0 10 20 30 40 50 60 70 80 90 100 %RH Temperature dependence: %RH 1. 0 0. 5 0 -10 -0. 5 -1. 0 0 10 20 30 40 50 60 °C Response time (90%) at 20 °C in still air Humidity sensor 6. 2 Temperature (Y model only) Measurement range Accuracy: °C 0. 5 0. 4 0. 3 0. 2 0. 1 0 -0. 1 -0. 2 -0. 3 -0. 4 -0. 5 -10 0 10 20 30 40 50 15 s HUMICAP 180 ® -5. . . +55 °C 60 °C Linearity Temperature sensor better than 0. 1 °C Pt 1000 IEC 751 class B 8 2000-08-23 U304en-1. 1 HMW70U/Y Transmitters Operating Manual 6. 3 General Supply voltage range depends on the selected output signal. DC 10. . . 35 V 14. . . 35 V 19. . . 35 V AC 9. . . 24 V 12. . . 24 V 16. . . 24 V 0. . . 1 V 0. . . 5 V 0. . . 10 V Factory setting 0. . . 1 V. An output change causes an error which is less than 0. 5 %RH without recalibration. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA HMW70Y




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA HMW70Y will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.