User manual VAISALA HMD70Y

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA HMD70Y. We hope that this VAISALA HMD70Y user guide will be useful to you.


VAISALA HMD70Y : Download the complete user guide (176 Ko)

Manual abstract: user guide VAISALA HMD70Y

Detailed instructions for use are in the User's Guide.

[. . . ] 4 Electrical connections and installation of the current module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3. 4. 1 Connection to an AC supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Electronics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 12 6. 4. 2 Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 GUARANTEE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 1997-07-31 i HMD70U/Y Transmitters Operating Manual U303en-1. 1 This page intentionally left blank. ii 1997-07-31 U303en-1. 1 HMD70U/Y Transmitters Operating Manual 1. PRODUCT DESCRIPTION The HMD70 transmitters are duct mounted three-wire transmitters for the measurement of humidity (HMD70U) and for the measurement of humidity and temperature (HMD70Y). The HMD70U/Y transmitters are easy to install and maintain: the electronics can be disconnected without dismantling the installation. One point calibration is easily performed with the HMI41 indicator and the calibration cable 19116ZZ. Both transmitter types incorporate the HUMICAP®180 humidity sensor which uses an operating principle based on changes in the capacitance of a thin polymer film as it absorbs water molecules. The HMD70Y transmitters measure temperature with the reliable Pt 1000 sensor. 1997-07-31 1 HMD70U/Y Transmitters Operating Manual U303en-1. 1 2. TO BE NOTED WHEN MEASURING HUMIDITY In the measurement of humidity and especially in calibration, it is essential that the temperature equilibrium is reached. Even a slight difference in the temperature between the measured object and the sensor causes an error. For example, at +20 °C (+ 68 °F) and 50 %RH, a temperature difference of +1 °C between the measured object and the sensor causes an error of +3 %RH. The error is at its greatest when the temperature of the sensor differs from that of the surroundings and the humidity is high. A few degrees' difference in temperature may cause water to condense on sensor surface. Efficient ventilation accelerates evaporation whereas in an unventilated space, it may take hours. The HUMICAP®180 sensor returns to its normal functioning as soon as water has evaporated. Any contaminated water condensing on the sensor may shorten its life span and change the calibration. 10 9 8 7 dRH (%RH) 6 5 4 3 2 1 0 -40 -20 0 20 40 60 80 100 Temperature (°C) Figure 2. 1 Measurement error at 100 %RH when the temperature difference between the ambient and the sensor is 1 °C 2 1997-07-31 U303en-1. 1 HMD70U/Y Transmitters Operating Manual 3. 3. 1 INSTALLATION Selecting the place of installation Select a place that gives a true picture of the environment or process and is as clean as possible. A rapid air flow is recommended as it ensures the same temperature for the ambient air and the sensor head. Install the transmitter in a place where no cold or hot spot can develop. If the sensor head is installed in a duct or channel where the temperature is different from the ambient temperature, insulate the point of entry. An uninsulated installation might lead to condensation on the sensor head and even if no condensation occurs, the resultant air flow may change the temperature near the sensor head and distort the readings. 3. 2 Mounting Mount the transmitter with two screws. Place the drilling template on the duct surface and drill the holes as indicated. Remember to drill an additional hole for calibration purposes. 62 (2. 44) 250 (9. 84) 100 (3. 94) (3. 23) >>> <<< Mounting hole 82 (3. 23) Figure 3. 2 Dimensions of the HMD70U/Y (in mm) 1997-07-31 Mounting hole 82 Ø 12 (0. 47) 100 (3. 94) 3 HMD70U/Y Transmitters Operating Manual U303en-1. 1 3. 3 Grounding Open the lid and mount the cable bushing set 18941HM. [. . . ] · Place the probe into the calibration hole of the LiCl bottle in the humidity calibrator. · Use the RH offset potentiometer (Figure 3. 4. ) to adjust the output signal to the value given in the calibration table (Chapter 4. 3). · Place the probe into the calibration hole of the NaCl bottle in the calibrator. · Check that the reading corresponds within the desired accuracy to the reading given in the calibration table. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA HMD70Y




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA HMD70Y will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.