GMW45 Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications
Features/Benefits
· · · · ·
Compact wall mount transmitter for demand controlled ventilation Incorporates Vaisala CARBOCAP® Sensor - the silicon-based NDIR sensor Excellent long-term stability Five year recommended calibration interval Easy-to-install
Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW45 is a basic wall mount transmitter for demand controlled ventilation.
The wall mount Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW45 is ideal for monitoring the air quality in public, commercial and residential buildings. [. . . ] Due to its built-in reference measurement capabilities and simple structure, the sensor is extremely stable and reliable. In addition, the measurement accuracy of the sensor is not affected by dust, water vapor or most chemicals.
Basic DCV transmitter
The GMW45 is a basic cost-effective CO2 transmitter intended to be used in building energy management systems. If CO2 transmitters with additional measurements are required, Vaisala offers a wide variety of wall and duct mount CO2, CO2 +T, RH and RH+T transmitters for demand controlled ventilation.
94
Vaisala Instruments Catalog 2005
Ref. A
GMW45
CARBON DIOXIDE
Technical Data
Carbon dioxide
Measuring range Accuracy at +25 °C (+77 °F) against certified factory references 0. . . 2000 ppm CO2 <±[40 ppm CO2+ 3% of reading] (includes repeatability and calibration uncertainty) <±1. 0 %FS 0. 15 %FS /°C <5. 0 %FS /5 years 5 years 1 minute -5. . . +45 °C (23 . . . 113 °F) 0. . . 85 %RH non-condensing Selectable 0. . . 20 mA or 4. . . 20 mA or 0. . . 10 V 10 ppm CO2
Dimensions
Dimensions in mm
Non-linearity Temperature dependence of output (typically) Long-term stability Recommended calibration interval Response time (0. . . 63%)
Operating conditions
Operating temperature range Humidity range
Wiring
24V GND OUT
0-10V 0-20mA 4-20mA
General
Output signals for CO2
OUTPUT SELECTION JUMPERS
0-10V SELECTED 0-20mA SELECTED
Resolution of analog outputs Recommended external load: current output max. [. . . ] ©Vaisala Oyj