User manual VAISALA GMM111 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA GMM111. We hope that this VAISALA GMM111 user guide will be useful to you.


VAISALA GMM111 DATASHEET: Download the complete user guide (276 Ko)

You may also download the following manuals related to this product:

   VAISALA GMM111 QUICK REFERENCE GUIDE (159 ko)

Manual abstract: user guide VAISALA GMM111DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. vaisala. com GMM111 Carbon Dioxide Module The Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is a CO2 measurement module with flow-through aspiration. Features/Benefits GMM111 The Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is designed especially for control of biological processes where high CO2 concentrations are used. [. . . ] The tunable FPI filter measures CO2 absorption, and simultaneously a reference wavelength. This internal reference measurement compensates effectively for any changes in the optical path, such as light source intensity changes and contamination. In the HVAC market, this type of reference measurement is a unique feature to Vaisala CARBOCAP® products. The true internal reference measurement of Vaisala CARBOCAP® CO2 transmitters provides years of stable CO2 measurements. Technical data Performance CO2 measurement range 0 . . . 20 % Accuracy (including repeatability, non-linearity and calibration uncertainty) ±(1. 5% of range + 3 % of reading) Long-term stability ±1 % CO2/2 years 1 min at 0. 5 l/min flow Response time T90 Flow rate dependence < 1 l/min flow no effect 1 . . . 10 l/min flow 4 % of reading/ l/min Temperature dependence, typical -0. 3 % of reading/°C Pressure dependence, typical +0. 15 % of reading/hPa Warm-up time 1 min, 10 min for full specifications Product lifetime > 10 years Dimensions Dimensions in mm mA V 0 B A 0 24V mA V 0 B A 0 24V 25 Ø3. 2 TUBE I. D. Ø6) 30 6 65 60 Operating environment Temperature +5 . . . 1200 hPa Gas flow operating range < 10 l/min recommended range 0. 2 . . . [. . . ] All specifications -- technical included -- are subject to change without notice. 96 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA GMM111




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA GMM111 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.