User manual VACCON HVP-100 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VACCON HVP-100. We hope that this VACCON HVP-100 user guide will be useful to you.


VACCON HVP-100 BROCHURE: Download the complete user guide (147 Ko)

Manual abstract: user guide VACCON HVP-100BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] HighVac Series Vacuum Pumps High Vacuum Venturi Pump up to 29. 5"Hg with Silencer HighVac Series: HVP 100, 200, 300 Ideal Applications: · Process control · Vessel evacuation · HVAC applications · Degassing Features/Benefits: · High performance ­ powerful vacuum up to 29. 5"Hg [999mbar] · Fast response time ­ no delay due to long plumbing lines; mounts in-line and installs close to vacuum point · Efficient minimal air consumption · Compact, lightweight and modular ­ easy to install HVP-100 degassing viscous liquids such as silicone and other mold compounds · Safe operation ­ no electricity needed at the pump · Reliable, trouble-free operation ~ No moving parts to wear ~ No flap valves to stick open ~ No maintenance ~ No downtime HVP Series Standard Pump: The HighVac Series of air-powered venturi vacuum pumps generate vacuum levels up to 29. 5" Hg [999mbar] and offer a wide range of vacuum flow rates. [. . . ] When complete, simply download the CAD drawing in any one of 13 different CAD formats and insert it right into your design. VACUUM PUMP VACCON MEDFIELD, MA 800-848-8788 L F AIR FLOW M E D F I E L D, M A 800 -848 -8788 ST-8A AIR FLOW ØS U ST SERIES SILENCER ST-8A E "A" AIR SUPPLY PORT K M N R 3X Ø D MOUNTING HOLES T Get the pump you need, in the format you like! Vacuum Pumps - High Vacuum 158 HVP-100 HVP-200 HVP-300 Specifications: Weight Noise Level 9oz [255g] 71 dB Specifications: Weight Noise Level 1 lb 11 oz [765g] 74 dB Imperial Dimensions (in. ) Specifications: Weight Noise Level 2 lb [907g] 79 dB Model # HVP-100 HVP-200 HVP-300 A 1/4 NPTF 1/4 NPTF 3/8 NPTF B 1/8 NPTF 1/4 NPTF 1/4 NPTF C 1/4 NPTF 1/2 NPTF 1/2 NPTF D 0. 12 0. 21 0. 21 E 0. 38 0. 50 0. 50 F 0. 38 0. 75 0. 75 H 2. 28 4. 02 4. 02 J 0. 75 1. 00 1. 00 K 0. 09 0. 20 0. 20 L 0. 67 N/A N/A M 1. 78 2. 20 2. 50 N N/A 3. 70 4. 00 P 3. 20 4. 00 5. 00 R 5. 06 7. 57 9. 81 S 0. 75 1. 00 1. 25 HVP Pump Standard Specifications: Pump Material: Cartridge Material: Medium: Operating Temperature: Operating Pressure: Anodized Aluminum (For silencer material, see Silencer section ­ page 235. Nylon, Buna-N (Other materials available, see page 7) Filtered (50 Micron) un-lubricated, noncorrosive dry gases -30°~250° F [-34°~121°C] 80 PSI [5. 5 BAR] standard or 60 PSI [4. 0 BAR] ­ Consult Factory for other operating pressures HVP Pump Installation Instructions: Vacuum Line & Supply Line ­ HVP100/200: 3/8" O. D. [10mm] tube recommended Vacuum Line Filtration ­ HVP100/200: Vacuum Line & Supply Line ­ HVP300: Vacuum Line Filtration ­ HVP300: Mounting Holes: Typically filters are not required, if desired Vaccon recommends ­ VF250. [16mm] tube recommended Typically filters are not required, if desired Vaccon recommends ­ VF375. HVP-100 = 4-40 [M3], HVP-200/300 = #10-32 [M5] screws Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon. com HighVac Series Vacuum Pumps HVP Series - Performance Data Model # HVP-100 HVP-200 HVP-300 Model # HVP-100 HVP- 200 HVP-300 Air Consumption SCFM 4. 90 8. 60 22. 00 O"Hg 1. 30 3. 45 6. 00 O"Hg 0. 00 0. 00 0. 00 3"Hg 1. 20 3. 25 5. 10 3"Hg 6. 50 2. 30 1. 20 6"Hg 1. 10 3. 05 Imperial ­ Vacuum Flow (SCFM) vs. Vacuum Level ("Hg) 9"Hg 12"Hg 15"Hg 18"Hg 21"Hg 1. 00 2. 75 0. 90 2. 45 0. 90 2. 05 0. 90 1. 90 0. 80 1. 60 24"Hg 0. 60 1. 30 27"Hg 0. 30 0. 90 0. 90 27"Hg 135. 50 67. 50 39. 50 29. 5"Hg 0. 00 0. 00 0. 00 29. 5"Hg 281. 30 125. 00 98. 10 4. 70 4. 40 4. 10 3. 60 3. 00 2. 60 1. 80 Evacuation Time in Seconds based on 1 Cubic Foot Volume/"Hg 6"Hg 9"Hg 12"Hg 15"Hg 18"Hg 21"Hg 24"Hg 12. 30 3. 80 2. 10 18. 90 6. 50 3. 40 32. 50 10. 20 5. 20 40. 00 14. 10 7. 70 52. 50 20. 00 11. 50 72. 50 29. 50 16. 30 98. 00 44. 00 24. 00 Note 1: Standard operating pressure for Vaccon pumps is 80 PSI [5. 5BAR]. Pumps can be factory modified to run at other operating pressures i. e. The values shown in the performance chart will remain the same for all operating pressures. [. . . ] Vacuum Level (mbar) 102 mbar 203 mbar 305 mbar 406 mbar 508mbar 609 mbar 711 mbar 813 mbar 914 mbar 999 mbar HighVac Series Vacuum Pumps Vacuum Pumps - High Vacuum 160 Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon. com [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VACCON HVP-100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VACCON HVP-100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.