User manual USP CONNECTORS 2007 CANADIAN PRODUCT CATALOGUE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual USP CONNECTORS 2007 CANADIAN PRODUCT CATALOGUE. We hope that this USP CONNECTORS 2007 CANADIAN PRODUCT CATALOGUE user guide will be useful to you.


USP CONNECTORS 2007 CANADIAN PRODUCT CATALOGUE : Download the complete user guide (13249 Ko)

Manual abstract: user guide USP CONNECTORS 2007 CANADIAN PRODUCT CATALOGUE

Detailed instructions for use are in the User's Guide.

[. . . ] 2007 CANADIAN PRODUCT CATALOGUE MAKING EVERYTHING BETTER LIMIT STATES DESIGN FROM OUR PRESIDENT As Group President of Gibraltar Industries Engineered Products Group and President of USP Structural Connectors® I'd like to thank you for your interest in USP. , It is our goal to provide the best available products and services to help you build safer and stronger structures. All of us at USP are focused on becoming the leader in the structural connector and engineered products market. Every day we look to provide true value to our customers in all of the industries and job functions that they perform in. [. . . ] · JUS - 16d sinkers (9 gauge x 31/4 ) may be used where 10d commons are specified with no load reduction. Typical JUS46 installation A © Copyright 2006 USP Structural Connectors® Dimple allows 30º to 45° nailing W D H JUS28 Double shear nail design features fewer nails and faster installation Uses standard length nails HUS28-2 HUS Specialty Options Chart ­ refer to Specialty Options pages 159 to 161 for additional details. Option Range Not available in widths less than 2-1/4. HUS410IF Typical HUS46 installation Ha ng ers Typical HUS410IF inverted flange installation 78 1-800-328-5934 · www. USPconnectors. com Standard ace Mount Hangers JR, & SUH Heavy-Duty FJoist Hangers ­ JL, ­ HD seriesseries HD hangers are heavy-duty face mount hangers that can be used to support headers, joists, and trusses. Materials: 14 gauge Finish: G90 galvanizing Options: All nominal lumber sizes are available for rough/full size lumber. Codes: CCMC 13116-R Load values are derived from data submitted to various North American building code evaluators. · Some HD models feature nail holes along bend line that must be filled to achieve allowable loads. Verify proper header width to accomplish this for inverted models. © Copyright 2006 USP Structural Connectors® Typical HD610 installation Typical HD210-2 installation A Bend line nailing H D W Drive bend line nails into header at 45° to achieve listed loads. HD610 Typical HD3212 glulam installation A Specialty Options Chart ­ refer to Specialty Options pages 159 to 161 for additional details. Option 4 Range 1° to 67-1/2° when width is 1-3/4 or less. Skewed1, 3 Sloped Seat2, 3 1° to 45° Sloped / Skewed1, 2, 3 Inverted Flange Not available in widths less than 2-1/4 100% of table load. HD410-SK45RSL30D H Allowable Loads 100% of table load Add SL, slope required, and up (U) or down (D), to product number. HD410-SL30D W D Ordering 1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. 2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails. 3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists. 4) Modifications of HD hangers may be manufactured as hot rolled, welded, or primed. Add SK, angle required, and right (R) or left (L), to product number. HD410-SK45R HD51135 Ha nge rs Typical HD210-2IF inverted flange installation 1-800-328-5934 · www. USPconnectors. com USP1060-061 79 F ace Mount Hanger Charts Dimensions USP Stock No. JL24 ST24 HDST24 JUS24 HD26 Steel Gauge 22 18 18 14 16 20 20 Fastener Schedule2, 3, 4 Factored Resistance (Lbs. ) Vertical 100% 655 785 670 920 945 670 790 805 985 1175 1000 1380 1225 1000 1195 3795 805 1615 985 1175 1640 1960 1340 1380 1840 1225 1550 1000 1195 1340 1590 3795 5640 1615 2420 1640 1960 2295 2745 1520 1840 1900 1880 1340 1590 1670 1985 5640 6040 2420 DF-L Uplift1 115% 305 370 370 635 Vertical 100% 550 660 670 920 790 560 665 675 830 985 1000 1380 1030 840 1005 3185 675 1355 830 985 1380 1645 1340 1380 1840 1030 1300 840 1005 1125 1335 3185 4735 1355 2030 1380 1645 1930 2305 1520 1840 1900 1580 1125 1335 1405 1670 4735 5075 2030 S-P-F Joist Size 2x4 SUH24 JL26 LU24L -- -LUS24 U24 HU26 LU24 Ref. No. 1-9/16 1-9/16 1-9/16 1-9/16 1-9/16 1-9/16 W H 3-1/4 3-1/4 3. 25 3-1/8 3-1/2 3 1-1/2 D 1-7/8 1-7/8 1-3/4 2 2 15/16 1-1/4 1-1/4 1 A 1-3/16 15/16 1-1/4 1-1/4 1 1-1/8 2x6 SUH26 ST26 HDST26 JUS26 LU26L -- -LUS26 U26 HUS26 HU26 HU28 LU26 LU28 LU26 22 18 18 16 14 14 20 20 16 1-9/16 1-9/16 1-9/16 1-5/8 1-9/16 1-9/16 1-9/16 1-9/16 5 5 4-13/16 5-7/16 3-1/2 5-1/4 4-3/4 6-3/8 5-1/8 4-3/4 1-1/2 1-7/8 1-7/8 1-3/4 2 3 2 2 JL26 JL28 HUS26 HD26 HD28 1-3/16 2 1-1/8 1-1/8 1-9/16 1-9/16 1-1/2 1-1/2 15/16 15/16 1-1/4 1-1/4 1-1/4 1 1 2x8 SUH26 SUH28 ST28 HDST26 HDST28 JUS26 JUS28 LU28L -- --- -LUS26 LUS28 U26 22 18 18 18 18 16 16 1-9/16 1-9/16 1-9/16 1-9/16 1-9/16 1-9/16 1-9/16 6-3/4 5 6-3/4 4-13/16 6-5/8 5-1/8 6-5/8 1-7/8 1-7/8 1-7/8 1-3/4 1-3/4 2 2 1-3/16 1-3/16 2 2 1-1/8 1-1/8 JL28 HUS26 HUS28 HD28 HD210 HUS26 HUS28 HU28 HU210 LU28 -- -- 16 16 14 14 20 20 1-5/8 1-5/8 1-9/16 1-9/16 1-9/16 1-9/16 5-7/16 7-3/16 5-1/4 7-3/16 6-3/8 8-1/4 1-1/2 1-1/2 3 3 2 2 15/16 15/16 1-1/4 1-1/4 1-1/4 1 2 x 10 SUH28 ST210 HDST28 HDST210 JUS210 SUH210 JL210 LU210L -- --- -LUS210 -- -U210 LU210 22 18 18 18 16 16 1-9/16 1-9/16 1-9/16 1-9/16 1-9/16 1-9/16 8 6-3/4 8 7-3/4 6-5/8 8 1-7/8 1-7/8 1-7/8 1-3/4 2 2 1-3/16 1-3/16 2 2 1-1/8 1) The uplift values are for short-term loads such as wind and earthquake. 3) Minimum nail embedment shall be 1-1/2 for 10d nails and 1-5/8 for 16d nails. 4) 16d sinkers (9 gauge x 3-1/4 long) may be used at 0. 84 of the table load where 16d commons are specified. HUS28 HUS210 HD210 HUS28 HUS210 HU210 16 16 14 1-5/8 1-5/8 1-9/16 7-3/16 9-3/16 7-3/16 3 3 2 (4) 10d (4) 16d (4) 10d x 1-1/2 (4) 10d x 1-1/2 (4) 10d (4) 10d (4) 16d (4) 16d (6) 10d (6) 16d (6) 10d x 1-1/2 (6) 10d x 1-1/2 (4) 10d (6) 10d (6) 16d (14) 16d (4) 16d (8) 16d (6) 10d (6) 16d (10) 10d (10) 16d (8) 10d x 1-1/2 (6) 10d x 1-1/2 (8) 10d x 1-1/2 (4) 10d (6) 10d (6) 10d (6) 16d (8) 10d (8) 16d (14) 16d (22) 16d (8) 16d (12) 16d (10) 10d (10) 16d (14) 10d (14) 16d (10) 10d x 1-1/2 (8) 10d x 1-1/2 (10) 10d x 1-1/2 (8) 10d (8) 10d (8) 16d (10) 10d (10) 16d (22) 16d (30) 16d (12) 16d Header (2) 10d x 1-1/2 (3) 8d x 1-1/2 (3) 8d x 1-1/2 (2) 10d Joist Uplift 1 115% 370 370 530 305 315 505 255 (2) 10d x 1-1/2 (4) 10d x 1-1/2 (5) 8d x 1-1/2 (5) 8d x 1-1/2 (4) 10d (2) 10d x 1-1/2 360 375 600 © Copyright 2006 USP Structural Connectors® (4) 10d x 1-1/2 620 620 1385 2390 360 760 600 1100 750 620 620 1165 2010 305 635 505 925 630 (4) 10d x 1-1/2 (6) 10d x 1-1/2 (7) 8d x 1-1/2 (5) 8d x 1-1/2 (7) 8d x 1-1/2 (4) 10d (4) 10d (6) 16d (2) 10d x 1-1/2 (4) 10d x 1-1/2 (4) 10d x 1-1/2 (6) 10d x 1-1/2 (6) 16d (8) 16d (4) 10d x 1-1/2 (4) 10d x 1-1/2 870 620 870 1385 1385 750 995 870 620 870 1165 1165 630 835 (6) 10d x 1-1/2 (8) 10d x 1-1/2 (8) 8d x 1-1/2 (7) 8d x 1-1/2 (8) 8d x 1-1/2 (4) 10d 1100 1360 2390 3190 760 760 2010 2680 635 635 925 (6) 10d x 1-1/2 (6) 10d x 1-1/2 990 870 990 1385 995 1140 990 870 990 1165 835 945 (8) 16d (10) 16d (4) 10d x 1-1/2 1125 3190 3980 760 2680 3345 635 Ha ng ers continued on next page 80 1-800-328-5934 · www. USPconnectors. com F ace Mount Hanger Charts continued Dimensions USP Stock No. ST212 JUS210 JL210 Steel Gauge 20 22 18 Fastener Schedule2, 3, 4 Factored Resistance (Lbs. ) Vertical 100% 2295 2745 1700 1880 1670 1985 6040 2420 3225 1130 1000 1195 805 1145 1380 1470 1730 1340 1590 805 1145 1485 2420 1510 1470 1860 2030 1340 1590 1670 1985 1485 2225 2420 2820 1640 1860 2590 2230 1670 1985 2340 2780 2225 2820 2965 3630 1900 2590 2990 2340 2780 2965 3630 3710 4435 1000 1195 805 1000 1195 1340 1590 1615 DF-L Uplift1 115% 1240 1385 1125 3980 760 1130 405 385 1360 Vertical 100% 1930 2305 1700 1580 1405 1670 5075 2030 2710 950 840 1005 675 960 1380 1235 1730 1125 1335 675 960 1245 2030 1510 1235 1560 2030 1125 1335 1405 1670 1245 1870 2030 2370 1640 1560 2175 2230 1405 1670 1965 2335 1870 2370 2490 3050 1900 2175 2510 1965 2335 2490 3050 3115 3725 840 1005 675 840 1005 1125 1335 1355 S-P-F Joist Size LU210 Ref. No. 2 x 12 © Copyright 2006 USP Structural Connectors® HUS210 HD210 HD212 JUS24-2 (2) 2 x 4 SUH210 -- -LUS210 U210 1-9/16 W HD24-2 HUS24-2 DT26 JUS26-2 HDDT26-TZ HD24-2 HUS24-2 HUS26-2 HD26-2 DT28 JUS26-2 JUS28-2 HDDT28-TZ SUH26-2 SUH28-2 SUH26-2 SUH24-2 U24-2 HUS210 HU210 HU212 LUS24-2 HU24-2 -- --- -LUS26-2 -- -HU24-2 -- -HUS26-2 HU26-2 -- -LUS26-2 LUS28-2 -- --- -- 16 14 14 18 14 14 22 18 18 14 14 14 14 22 18 18 18 16 16 16 16 16 1-9/16 1-9/16 1-9/16 1-5/8 1-9/16 1-9/16 3-1/8 3-1/8 10 7-3/4 9-3/16 7-3/16 9-1/4 3-7/16 3-1/2 3-7/16 5 5-1/4 5 3-1/2 3-7/16 5-1/4 5-1/8 6-3/4 5-1/4 7-1/8 6-3/4 6-1/4 3-1/8 8 8-1/4 H 1-1/2 D 1-7/8 1-3/4 2 3 2 2 2 15/16 1-1/4 1 A 1-3/16 2 1-1/8 1-1/8 1 (2) 2 x 6 U26-2 3-1/8 3-1/8 3-1/16 3-1/8 3-1/16 3-1/8 3-1/8 3-1/8 3-1/8 3-1/16 3-1/8 3-1/8 3-1/16 3-1/8 3-1/8 3-1/8 5-1/16 2-1/2 2 2 2 2 2-1/2 2 2 2-1/2 2 2 2 2 2 2 2 2 1-1/8 1 1-1/4 1 1-1/4 1-1/8 1-1/8 1 1 1-1/8 1-1/4 1 1 1-1/4 1-1/8 (2) 2 x 8 U26-2 5-1/16 1-1/8 1-1/8 HUS26-2 HUS28-2 HD26-2 HD28-2 DT210 JUS28-2 JUS210-2 HDDT210-TZ (2) 2 x 10 SUH28-2 SUH210-2 HUS26-2 HUS28-2 HU26-2 HU28-2 -- -LUS28-2 LUS210-2 -- --- -U210-2 14 14 14 14 22 18 18 18 16 16 3-1/8 3-1/8 3-1/8 3-1/8 3-1/16 3-1/8 3-1/8 3-1/16 3-1/8 3-1/8 5-1/4 7-1/8 5-1/8 7-1/8 7-7/8 7-1/8 9-1/8 7-7/8 6-1/4 8-9/16 2 2 2-1/2 2-1/2 2 2 2 2 2 2 1-1/8 1-1/8 1 1 1-1/8 1-1/8 1-1/4 1 1 1-1/4 HUS28-2 HD28-2 HUS210-2 HD210-2 DT212 JUS210-2 JUS212-2 (2) 2 x 12 HUS210-2 HD210-2 HUS212-2 HD212-2 HD34 SUH210-2 U210-2 HUS28-2 HU28-2 HUS210-2 HU210-2 -- -LUS210-2 -- -HUS210-2 HU210-2 HUS212-2 HU212-2 HU34 14 14 14 14 22 18 18 16 14 14 14 14 3-1/8 3-1/8 3-1/8 3-1/8 3-1/16 3-1/8 3-1/8 3-1/8 3-1/8 3-1/8 3-1/8 3-1/8 8-9/16 7-1/8 7-1/8 9-1/8 9 10 9-1/8 11-1/8 2 2-1/2 2 2-1/2 2 2 2 2 2-1/2 2 2-1/2 2 2 2 2 2 1 1-1/8 1 1-1/8 1-1/4 1 1 1-1/8 1 1-1/8 1 1-1/8 3x4 SUH34 SUH34 SUH36 HD36 U34 U34 U36 14 16 16 16 2-9/16 2-9/16 2-9/16 2-9/16 9-1/8 9 11-1/8 11 3-3/8 3-3/8 3 1-1/8 1-1/8 1-1/8 1-1/8 3x6 HU36 14 2-9/16 5-5/16 4-3/4 2 1-1/8 (14) 10d (14) 16d (12) 10d x 1-1/2 (8) 10d (10) 10d (10) 16d (30) 16d (12) 16d (16) 16d (4) 16d (6) 10d (6) 16d (4) 16d (4) 16d (8) 16d x 2-1/2 (4) 16d (8) 16d x 2-1/2 (8) 10d (8) 16d (4) 16d (4) 16d (4) 16d (12) 16d (10) 16d x 2-1/2 (4) 16d (6) 16d (10) 16d x 2-1/2 (8) 10d (8) 16d (10) 10d (10) 16d (4) 16d (6) 16d (12) 16d (14) 16d (12) 16d x 2-1/2 (6) 16d (8) 16d (12) 16d x 2-1/2 (10) 10d (10) 16d (14) 10d (14) 16d (6) 16d (14) 16d (8) 16d (18) 16d (14) 16d x 2-1/2 (8) 16d (10) 16d (14) 10d (14) 16d (8) 16d (18) 16d (10) 16d (22) 16d (6) 10d (6) 16d (4) 16d (6) 10d (6) 16d (8) 10d (8) 16d (8) 16d Header (8) 10d x 1-1/2 (10) 8d x 1-1/2 (4) 10d Joist Uplift 1 115% 1140 (6) 10d x 1-1/2 1240 1165 3345 635 950 340 330 515 620 1415 620 330 515 1165 985 870 1415 1415 870 645 645 645 325 945 (10) 16d (4) 10d x 1-1/2 (6) 10d x 1-1/2 (2) 16d (2) 10d (2) 16d (5) 8d x 1-1/2 (4) 16d (5) 8d x 1-1/2 (2) 10d (2) 16d (4) 16d (6) 10d (7) 8d x 1-1/2 (4) 16d (4) 16d (7) 8d x 1-1/2 (4) 10d (4) 10d (4) 10d (2) 10d 390 615 620 1685 620 390 615 1385 1175 870 1685 1685 870 770 770 770 (4) 16d (6) 16d (6) 10d (6) 10d (8) 8d x 1-1/2 (4) 16d (6) 16d (8) 8d x 1-1/2 (4) 10d (6) 10d 1385 2250 1175 1175 990 1685 2460 990 770 1155 1165 1890 985 985 990 1415 2065 990 645 970 (6) 16d (6) 10d (8) 16d (10) 10d (10) 8d x 1-1/2 (6) 16d (6) 16d (8) 16d (10) 10d (10) 16d (10) 10d (6) 10d 2250 1175 2745 1955 1240 2460 2460 1155 2745 1955 3800 1955 360 375 375 750 1890 985 2305 1645 1240 2065 2065 2305 1645 3190 1645 305 315 315 630 970 (2) 10d x 1-1/2 (2) 10d x 1-1/2 (4) 10d x 1-1/2 (2) 10d x 1-1/2 Ha nge rs (4) 10d x 1-1/2 760 635 continued on next page 1-800-328-5934 · www. USPconnectors. com USP1060-061 81 F ace Mount Hanger Charts Dimensions USP Stock No. SUH36 HD36 HD38 Steel Gauge 14 14 16 continued Fastener Schedule2, 3, 4 Factored Resistance (Lbs. ) Vertical 100% 1340 1590 1615 2420 2340 2780 2420 2820 2340 2780 2420 2820 3225 4840 1470 1340 1590 1145 1485 2420 1470 1860 1340 1590 1670 1985 1485 2225 2420 2420 1860 2590 1670 1985 2340 2780 2225 2420 2965 3630 2590 2990 2340 2780 2965 3710 4435 1130 1000 1195 805 1145 DF-L Uplift1 115% 760 760 750 Vertical 100% 1125 1335 1355 2030 1965 2335 2030 2370 1965 2335 2030 2370 2710 4065 1235 1125 1335 960 1245 2030 1235 1560 1125 1335 1405 1670 1245 1870 2030 2030 1560 2175 1405 1670 1965 2335 1870 2030 2490 3050 2175 2510 1965 2335 2490 3115 3725 950 840 1005 675 960 S-P-F Joist Size 3x8 U36 Ref. No. 3 x 10 HD38 HD310 SUH310 3 x 12 3 x 16 HD38 HD310 HD312 HD316 JUS26-3 SUH310 HU38 HU310 HU38 HU310 HU312 HU316 LUS26-3 -- --- --- -LUS26-3 LUS28-3 U310 U310 HU36 HU38 14 14 14 14 14 14 18 14 14 14 18 18 16 16 16 16 2-9/16 2-9/16 2-9/16 W 5-5/16 4-3/4 6-3/4 H D 2 2 2 1-1/8 A 2-9/16 2-9/16 2-9/16 2-9/16 2-9/16 2-9/16 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 2-9/16 2-9/16 6-3/4 7-7/16 6-3/4 7-7/16 9-5/16 13-5/16 4-1/2 3-11/16 4-1/2 4-3/8 4-1/2 6-3/8 5-1/4 7-1/8 5-1/4 8-7/8 8-7/8 2 2-1/2 2 2-1/2 2-1/2 2-1/2 2 2 2 2-1/2 2 2 2 3 2 2 2 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8 (3) 2 x 6 HUS24-3 HUS26-3 HD26-3 JUS26-3 JUS28-3 SUH26-3 SUH26-3 U26-3 1-1/8 1-1/8 1-1/8 1-1/8 1 1 1 1-1/8 1 1 1 1 1 U26-3 (3) 2 x 8 HUS26-3 HUS28-3 HD26-3 HD28-3 JUS28-3 JUS210-3 SUH28-3 SUH28-3 -- --- -HU26-3 -- -LUS28-3 LUS210-3 -- -- -- -- 14 14 14 14 18 18 16 16 16 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 4-5/8 7-1/8 8-3/8 4-1/2 6-3/8 4-3/8 6-3/8 6-3/8 8-3/8 2 2 2-1/2 2-1/2 2 2 3 2 1 1 1-1/8 1-1/8 1 1 1 1 (3) 2 x 10 HUS28-3 HD28-3 HUS210-3 HD210-3 JUS210-3 JUS212-3 HUS210-3 HUS212-3 HD212-3 JUS44 SUH210-3 SUH210-3 U210-3 (3) 2 x 12 4x4 SUH44 -- --- -HU212-3 LUS44 U44 HU44 -- -- U210-3 -- --- --- -HU210-3 LUS210-3 -- -- 14 14 14 18 14 14 16 16 14 14 14 14 18 18 1) The uplift values are for short-term loads such as wind and earthquake. 3) Minimum nail embedment shall be 1-1/2 for 10d nails and 1-5/8 for 16d nails. [. . . ] · Specify if hanger is to be high side flush, low side flush, or centre flush. Sloped/Skewed/Sloped Top Flange Hanger: · See nailing notes for both skewed and sloped hangers. · Specify skew, slope, and top flange slope angles as well as skew/slope and top flange slope directions when ordering. · Skewed/sloped/top flange sloped hangers can be made galvanized or painted. Specify angle Typical HD hanger inverted flange Specify angle Typical BPH hanger skewed, left shown Type A (bevel cut required) Specify angle Plumb height Joist height Typical BPH hanger skewed, right shown Type B Skew angle Slope angle Typical BPH hanger Typical BPH hanger sloped seat, down shown sloped down, skewed right, low side flush shown Specify angle Specify angle high side flush center flush low side flush Joist skew right shown Slope angle Typical BPH hanger skewed right, sloped down, top flange sloped Typical LBH hanger sloped top flange right shown 160 1-800-328-5934 · www. USPconnectors. com Solid Top Flange Hanger Specialty Details See Specialty Options Chart for each hanger series for load reductions and hanger maximum range of skew, slope, etc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE USP CONNECTORS 2007 CANADIAN PRODUCT CATALOGUE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual USP CONNECTORS 2007 CANADIAN PRODUCT CATALOGUE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.