User manual UNOMAT VAX-II SPECIFICATION
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual UNOMAT VAX-II. We hope that this UNOMAT VAX-II user guide will be useful to you.
Manual abstract: user guide UNOMAT VAX-IISPECIFICATION
Detailed instructions for use are in the User's Guide.
[. . . ] VAX II
VAX -
II
cd
n Generates pulses and read frequency n Converts any input into any output signal n Powers, reads and simulates digital sensors n Sources and reads mV, V and mA n Powers, reads and simulates 2-wire transmitters n Simultaneous input and output readings n Outputs pre-set numbers of pulses n Scale factors for flow readings n Stop-watch pulse counting
Multi-calibrator for PLC's and Control Systems
VAX - II
Standard Specifications
SPECIFICATIONS
cd
Resolution
0. 01 mV 0. 01 mV 0. 01 V 0. 001 V 0. 01 mA 0. 01 mA 0. 01mA 0. 01 Hz, f < 100 Hz 1 Hz, f > 100 Hz 1 count 1 count 0. 01Hz 1 Hz
Function
Measure mVolts Output mVolts Measure Volts Output Volts Measure mA Output mA Transmitter Simulation Measure frequency Counter input Counted pulse output Pulse output low freq. [. . . ] 0 - 24 V/34 mA max.
Frequency counter input threshold Selectable at 0. 02, 0. 05, 0. 1, 0. 2, 0. 5, 1. 0, 2. 0, 5. 0 Volts Pulse output level Adjustable from 0. 1 to 24 Volts with a resolution of 0. 1 Volts Output pulse form AC symmetrical square wave, -50 mV zero based Pulse output transmission speed Adjustable from 1 to 10. 000 bauds Pulse output frequency Selectable in Hz, Pulses/min. Transmitter (signal converter) Calibration reference 220 C (71. 60F) ± 10C Calibration Traceable to international standards with correlation to NIST Long term stability ± 0. 03% of range/year Indicated accuracies Specified for 150C (600F) to 350C (950F). on zero and ± 0. 001% / 0C of span Operating temperature -100C to +500C (140F to 1220F) Storage temperature -200C to + 700C (-40F to 1580F) Warm up time 2 minutes to rated accuracy Relative humidity 0 to 90% non-condensing Input/Output protection 70 Volts on millivolt input, 30 Volts on outputs, 200Volts on Volts input Input/Output isolation 500VDC continuous
Output Voltage Protected by load monitor, displays "load resistance too low" Output Current Protected by load monitor, displays "check loop" Transmitter power supply 24VDC output current limited at 34 mA Read-out Simultaneous read-out of input and output values 3¾ or 4½ digits, depending on the selected range. Dialogue in English Batteries 4 x 1. 5 Volt, type LR14 (size C) alkaline or rechargeable NiCd Battery life 22 hours with alkaline batteries at 200C (680F) 7 hours with 20 mA load Low battery indication "Bat" flashes as a pre-warning. [. . . ] Continuing development sometimes necessitates specification changes without notice.
cd
Druck Limited Fir Tree Lane, Groby Leicester LE6 0FH England Tel: +44 (0) 116 231 7100 Fax: +44(0) 116 231 7103 E-mail: sales@druck. com Internet: www. druck. com