User manual UNIDEN UBC3500XLT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual UNIDEN UBC3500XLT. We hope that this UNIDEN UBC3500XLT user guide will be useful to you.


UNIDEN UBC3500XLT : Download the complete user guide (794 Ko)

Manual abstract: user guide UNIDEN UBC3500XLT

Detailed instructions for use are in the User's Guide.

[. . . ] UBC3500XLT OWNER'S MANUAL OWNER'S MANUAL Precautions Before you use Precautionsthis scanner, please read and observe the following. Use of an incorrect earphone or stereo headset might be potentially hazardous to your hearing. The output of the phone jack is monaural, but you will hear it in both headphones of a stereo headset. Set the volume to a comfortable audio level coming from the speaker before plugging in the monaural earphone or a stereo headset of the proper impedance (32 ). [. . . ] · When scanning multiple systems, the UBC3500XLT scans systems according to the assigned quick key. Systems not assigned to a quick key are scanned last, then unlocked searches. Within a quick key, systems are scanned in the order they were assigned. · Within a system, channels are scanned according to the assigned channel group, with the same priority as described above for systems. · The UBC3500XLT scans a system for the duration you set using the System Hold Time option (see "Setting the System Hold Time" on Page 47). Conventional systems operate similarly, but all unlocked channels are scanned at least one time regardless of the hold time setting. · Each search range is searched for the amount of time you set using the "Set Hold Time" option. See "Setting the System Hold Time" on Page 47 for more information. Selecting Systems to Scan To select systems to scan, press Scan then press the quick key assigned to the system or systems you want to scan. For quick keys 10-99, press then press the 32 quick key's 2-digit number. To stop scanning the system(s), press (if the quick key is a 2-digit quick key) then the number button or buttons again. The Sx: (system) indicators on the display show the systems that are currently selected. To select or lock out a system that is not assigned to a key, press and hold Func while you rotate the scroll control until the desired system is selected. Then, continue to hold Func and press L/O to either lock out or unlock the system. Selecting System Channel Groups Within a system, you can assign groups of channels to a group quick key (see "Setting the Group Quick Key" on Page 50). Follow these steps to activate or deactivate a channel group within a system while scanning. Press Func to hold on the system (or hold down Func then rotate the scroll control to select the system). Continue to hold Func and press the number key corresponding to the channel group you want to activate or deactivate. Locking/Unlocking Systems Follow these steps to lock out a system so that it does not scan even if its quick key is selected. While holding down Func , rotate the scroll control to select the system. System Unlocked appears. Basic Operation 33 Locking/Unlocking Channels Follow these steps to lock out a channel so that it does not scan even if its system and channel group are selected. While holding down Func , rotate the scroll control to select the system where the channel is stored. Rotate the scroll control to select the channel you want to lock or unlock. You can also lock out an active channel by pressing L/O while the scanner is stopped on the channel. Temporarily Holding On a System To temporarily hold on a system, press and hold Func . To hold on a different system, continue to hold Func and rotate the scroll control to select the system. [. . . ] Scanner displays The contents of scanner's memory might be changed to malformed value. Memory Error. 82 Specifications Specifications Dynamic Allocation Capacity Systems: 200 max Groups: 20 per system Channels: 2500 Band Coverage: 21 Bands Attenuation: 25 dB (nominal) Certified in accordance with ETSI, as of date of manufacture. Frequency Range (MHz):See page 6 to 7 Sensitivity (nominal) 12dB SINAD : 0. 3uV 25 - 87. 295 MHz 0. 7uV 87. 3 - 107. 95 MHz 0. 4uV 108 - 136. 9916 MHz 0. 3uV 137 - 173. 9937 MHz 0. 7uV 174 - 215. 95 MHz 0. 3uV 216 - 224. 995 MHz 0. 4uV 225 - 399. 95 MHz 0. 3uV 400 - 512 MHz 0. 4uV 806 - 960 MHz 0. 5uV 1240 - 1300 MHz Operating Temperature: Normal ­20°C to +60°C Close Call ­10°C to +60°C Scan Rate: 100 channels per second MAX (conventional mode) Search Rate: 300 steps per second (5 kHz step only)MAX FM FMB AM FM WFM FM AM FM FM FM Specifications 83 Audio Output: 500mW nominal into 24 internal speaker 110 mW nominal into 32 headphone Power Requirements: 3 AA Alkaline Batteries (not included), or 3 AA Rechargeable Ni-MH Batteries (2300 mAh)(Included), or AC Adapter (AC230V 50Hz 6V 800mA Regulated)(AD-818)(Included) External Jacks: Antenna Jack SMA Type Headphone Jack 3. 5mm Stereo Type DC Power Jack (EIAJ TYPE-2 Center Positive) Remote Jack 4 Pin Mini Size: 61. 0 mm (W) x 31. 0 mm (D) x 130. 5 mm (H) Weight: 182. 5 g (without batteries and antenna) 84 Optional Accessories Earphone Connection Cable fi External Amplified Speaker Specifications 85 Appendix Appendix Edit Sys Option Initial Setting of the Menus. Parameter Initial 1 Band Plan(Factory Default Setting) *Band Plan Number does not be initialzed by turning the scanner on by pressing and hoding [2] key + [9] key + [Hold] key. Program System Edit Name Set Quick Key Set Lockout Set Hold Time Set Delay Time Set Data Skip Edit Name Set Quick Key Edit Channel Edit Group Edit Name Set Priority Set Alert Set CTCSS/DCS Set Modulation Set Attenuator Set Lockout Srch/CloCall Opt Freq Lockouts Set Lockout Unlock All Rvw Search L/O Broadcast Screen Set Each Band 1 Band Band 2 : Band 10 Select Band 1 - 10 Program Band Set Lower Limit Set Upper Limit CTCSS/DCS Search Max Auto Store Set Delay Time Set Modulation Set Attenuator Set Data Skip Set Step Air Band Step (This is named automatically. ) . (dot) (This is named automatically. ) Off Off Off Auto Off Unlocked Unlocked (Not Stored. ) (Not Stored. ) Off Off : Off 0. 0000 0. 0000 (MHz) (All Band) Off 100 2 sec Auto Off Off Auto 12. 5 kHz 86 Parameter Search for. . . Edit Service Set Delay Time Set Attenuator Search Set Lockout with Set Hold Time Scan Edit Name Initial 2 sec Off Lockout 2 Custom 1 Custom 2 : Custom 10 Custom 1: Plan 1 : 25. 0000 - 87. 2875 Plan 2 : 25. 0000 - 87. 2950 Plan 3 : 25. 0000 - 87. 2937 Custom 2 : 87. 3000 107. 9500 Custom 3 : 108. 0000 136. 9875 Custom 4 : Plan 1, 2 : 137. 0000 173. 9950 Plan 3 : 137. 0000 173. 9937 Custom 5 : 174. 0000 215. 9950 Custom 6 : 216. 0000 224. 9950 Custom 7 : 225. 0000 399. 9500 Custom 8 : 400. 0000 512. 0000 Custom 9 : 806. 0000 960. 0000 Custom 10 : 1240. 000 1300. 0000 2 sec Auto Off Off Auto Lockout 2 Edit Custom (All Custom Search Range) Edit Srch Limit Set Delay Time Set Modulation Set Attenuator Set Data Skip Set Step Set Lockout Search with Set Hold Time Scan Appendix 87 Parameter Close Call Set CC Mode Set CC Override Set CC Alert Initial Off On Beep+Light Alert 1 Level : Auto 3 sec On On On On On On On Off Tone-Out 1 Tone-Out 2 : Tone-Out 10 Tone-Out 1 : 137. 0000 MHz Tone-Out 2 : 138. 0000 MHz : Tone-Out 10 : 146. 0000MHz FM Off 1000Hz 2000Hz 2 sec Off Master 10 sec Auto On Off Contrast 8 115200 bps 0% Version x. xx. xx Select Mode Select Beep Set CC Pause VHF Low 1 VHF Low 2 Air Band VHF High 1 VHF High 2 UHF 800MHz+ Edit Name Set CC Bands Set Priority Tone-Out for. . . Tone-Out Setup Set Frequen cy Edit Frequency Set Modulation Set Attenuator Set Tone Edit Tone A Edit Tone B Set Delay Time Set Alert Wired Clone Settings Set Backlight Adjust Key Beep Set Battery Save Set Audio AGC Adjust Contrast PC Controls See Scanner Info % Memory Used Firmware Version 88 Planning Planning Getting your scanner programmed and scanning takes Collecting Information a few steps. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE UNIDEN UBC3500XLT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual UNIDEN UBC3500XLT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.