User manual UNIDEN SC200 BEARCAT SCANNER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual UNIDEN SC200 BEARCAT SCANNER. We hope that this UNIDEN SC200 BEARCAT SCANNER user guide will be useful to you.


UNIDEN SC200 BEARCAT SCANNER : Download the complete user guide (1295 Ko)

Manual abstract: user guide UNIDEN SC200 BEARCAT SCANNER

Detailed instructions for use are in the User's Guide.

[. . . ] SC200 200-Channel Programmable Twin Turbo Hand-Held Sports Scanner OPERATING GUIDE Precautions Before you use this scanner, please read and observe the following: n WARNING!To reduce the risk of fire or electrical shock, DO NOT expose this unit to rain or moisture. Be sure to use only the supplied earphone, or a stereo headset of the proper impedance (32W ). Use of an incorrect earphone or stereo headset may be potentially hazardous to your hearing. n n WARNING: Set the volume to a comfortable audio level coming from the speaker before plugging in the supplied earphone or a stereo headset of the proper impedance (32W ). [. . . ] If the Priority Channel in any Bank is "Locked Out", it will be skipped during scanning. You can move the Priority to any other channel in a Bank as follows: 1. Go directly to that channel using any of the methods described above. 2. You will hear "two beeps, " and P will appear on the display to the left of the new channel number. (The P will no longer appear for the previous Priority Channel. ) To activate Priority Scan, press . The PRIORITY indicator will disappear from the bottom of the display. Delay Normally the scanner will resume scanning when a transmission stops. If you want to remain on a channel until a responding transmission is received, activate the DELAY feature. This feature can be active in SCAN, MANUAL, SEARCH, and WEATHER Modes. 1. The scanner will now pause 2 seconds after transmission stops before resuming scanning. Press 24 Locking Out Channels You may have programmed certain channels that you do not want to hear every time you scan. These might be channels that are busy a major portion of the time, causing the scanner to stop at the channel(s) often enough to interrupt the scan cycle. Go directly to the channel using any of the methods described above. 2. L/O appears on the display. That channel is now "Locked Out" of the scanning cycle. The L/O indicator now disappears from the display, and the channel is no longer "Locked Out". You can lock out any or all of the Priority Channels in the same way as other channels. If you lock out all Priority Channels you will see this message in Priority Mode: You can also remove L/O from all "Locked Out" channels in the selected Scan Banks (those appearing on the display. ) Press and hold for at least 2 seconds. You will hear 2 beeps and all channels except empty channels (000. 0000MHz) are returned to the scanning cycle in the selected Scan Banks. Looking for "Locked Out" Channels During scanning, you will not see "Locked Out" channels. To look for "Locked Out" channels, first press to stop scanning. You will see L/O on the display to indicate a "Locked Out" channel. 25 Weather Channel Scanning The SportCat is designed to search for your local NOAA and Canada weather channel(s) from 10 preprogrammed NOAA and Canada channels. 1. WX appears at the lower side of the display and the word SCAN moves across the display. To stay at that frequency, press To resume Weather scan, press or /ATT. . It is possible for you to hear more than one Weather broadcast in your area. If the broadcast sounds weak and distant, press /ATT again to look for a closer station. [. . . ] If the scanner is exposed to temperatures below -5°F or above 140°F, the liquid crystal display may temporarily cease to function properly, or can become permanently damaged. 49 Technical Specifications Receiver Type: Channels: Banks: WX: Search Bands: Triple Conversion Superheterodyne 200 Total 10 Banks 20 Channels each 10 Programmed Channels (All NOAA Weather Service and three Canadian wheather service) 12 Preprogrammed Search bands (NFM or AM) BAND NFM NFM NFM AM NFM NFM NFM NFM NFM NFM NFM NFM NFM NFM STEP (kHz) 5 5 5 12. 5 5 5 5 12. 5 12. 5 12. 5 12. 5 12. 5 12. 5 12. 5 No. 1 2 3 4 5 6 7 8 9 10 11 12 RANGE (MHz) 29. 0000-29. 9950 30. 0000-49. 9950 50. 0000-54. 0000 108. 0000-136. 9875 137. 0000-143. 9950 144. 0000-147. 9950 148. 0000-174. 0000 406. 0000-419. 9875 420. 0000-449. 9875 450. 0000-469. 9875 470. 0000-512. 0000 806. 0000-823. 9875 849. 0125-868. 9875 894. 0125-956. 0000 100 channels per second 100 steps per second (Normal Search Mode) 300 steps per second (Turbo Search Mode) Scan Delay: 2 seconds Audio Output: 180 mW nominal into 8W internal speaker 38 mW nominal into 32W stereo headphones 9 mW nominal into 64W supplied earphone Antenna: Rubber antenna included Operating Temperature: - 20°C (- 4°F) to + 60°C (+ 140°F) Scan Rate: Search Rate: 50 Size: 2-1/2" (W) x 1-3/4" (D) x 11-3/4" (H) (with antenna attached) 65 mm (W) x 39. 5 mm (D) x 296. 5 mm (H) (w/antenna w/o belt clip) Weight: 0. 71 lb. (320 g) Power Requirements: 4. 8V DC (internal battery or AC Adapter/Charger) Certified in accordance with FCC Rules and Regulations Part 15 Subpart C as of date of manufacture. Features, specifications, and availability of optional accessories are all subject to change without notice. 51 CTCSS/CDCSS Tone Frequencies (Hz) CTCSS 67. 0 97. 4 136. 5 192. 8 71. 9 100. 0 141. 3 203. 5 74. 4 103. 5 146. 2 210. 7 77. 0 107. 2 151. 4 218. 1 79. 7 110. 9 156. 7 225. 7 82. 5 114. 8 162. 2 233. 6 85. 4 118. 8 167. 9 241. 8 88. 5 123. 0 173. 8 250. 3 91. 5 127. 3 179. 9 94. 8 131. 8 186. 2 CDCSS 023 054 125 165 245 274 356 445 506 627 732 025 065 131 172 246 306 364 446 516 631 734 026 071 132 174 251 311 365 452 523 632 743 031 072 134 205 252 315 371 454 526 654 754 032 073 143 212 255 325 411 455 532 662 036 074 145 223 261 331 412 462 546 664 043 114 152 225 263 332 413 464 565 703 047 115 155 226 265 343 423 465 606 712 051 116 156 243 266 346 431 466 612 723 053 122 162 244 271 351 432 503 624 731 52 Optional Accessories and Replacement Parts The following optional accessories and replacement parts for your SportCat are available from your local Uniden Dealer or through the Uniden Customer Service Center by calling: 1-800-297-1023, 7:00 AM to 7:00 PM Central Time, Monday through Friday. ITEM Spare Battery Pack Replacement Rubber Antenna Earphone AC Adapter/Charger Straight Cigarette Lighter Power Cord (fused) Coiled Cigarette Lighter Power Cord (fused) Belt Clip with 2 screws SportCat Sports Frequency Guide SportCat Operating Guide Remote Cable PART NO. BP-180 AT-218 EP-009 AD-70U UA-502 UA-502A BCK-150 FB-150 OMSC200 WZ-1407 53 Troubleshooting If your SC200 is not performing properly, try the following steps. PROBLEM Scanner won't work. SOLUTION 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE UNIDEN SC200 BEARCAT SCANNER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual UNIDEN SC200 BEARCAT SCANNER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.