User manual UNIDEN GMR1235-2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual UNIDEN GMR1235-2. We hope that this UNIDEN GMR1235-2 user guide will be useful to you.


UNIDEN GMR1235-2 : Download the complete user guide (153 Ko)

You may also download the following manuals related to this product:

   UNIDEN GMR1235-2 (208 ko)

Manual abstract: user guide UNIDEN GMR1235-2

Detailed instructions for use are in the User's Guide.

[. . . ] In order to speak to someone, each of you must be set to the same channel. To choose a channel: Press the ch/scan L or M key to increase or decrease the channel number displayed. Channel Scan Feature Your GMR1235-2 radio has a channel scan feature that allows you to easily scan all 22 channels. When an active channel is detected, the unit pauses on that channel until the channel is clear. [. . . ] If you have any questions you can contact the FCC direct at 1-888-225-5322. SPECIFICATIONS Channels Operating Frequency Power Source Battery Life Frequency Chart Ch. 1 2 3 4 5 6 7 8 9 10 11 Freq. [MHz] 462. 5625 462. 5875 462. 6125 462. 6375 462. 6625 462. 6875 462. 7125 467. 5625 467. 5875 467. 6125 467. 6375 Cross Ref. FRS & GMRS 1 FRS & GMRS 2 FRS & GMRS 3 FRS & GMRS 4 FRS & GMRS 5 FRS & GMRS 6 FRS & GMRS 7 FRS 8 FRS 9 FRS 10 FRS 11 Ch. 12 13 14 15 16 17 18 19 20 21 22 Freq. [MHz] 467. 6625 467. 6875 467. 7125 462. 5500 462. 5750 462. 6000 462. 6250 462. 6500 462. 6750 462. 7000 462. 7250 Cross Ref. FRS 12 FRS 13 FRS 14 GMRS 11 GMRS 8 GMRS 12 GMRS 9 GMRS 13 GMRS 10 GMRS 14 GMRS 15 15 GMRS / 7 FRS UHF 462. 5500467. 7125 MHz 3 AAA Alkaline Batteries 20 Hours typical (5/5/90 duty cycle) *Range may vary depending on environmental and/or topographical conditions. INSTALL THE BATTERIES Your GMR1235-2 radio uses 3 AAA alkaline batteries for power. 2) Remove the battery compartment door by pressing on and sliding the compartment door, and remove the cover. Installing the batteries incorrectly will prevent the unit from operating. 4) Replace the battery compartment door by sliding the door into place. 1 2 3 4 5 6 7 8 9 Antenna PTT (Push-To-Talk) Button Channel/Scan up Key Call/lock Key Channel/Scan down Key Speaker Volume up/Monitor Key Power On/Off Key Volume down/Monitor Key 10 11 12 13 14 Microphone Channel Indicator Receive Indicator Battery Level Indicator Transmit Indicator FCC INFORMATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Important: Changes or modifications to this unit not expressly approved by Uniden could void your authority to operate this unit. Your radio is set up to transmit a regulated signal on an assigned frequency. It is against the law to alter or adjust the settings inside the radio to exceed those limitations. · Never change or replace anything in your radio except the batteries. Your radio might cause TV or radio interference even when it is operating properly. To determine whether your radio is causing the interference, turn it off. Try to eliminate the interference by moving your radio away from the receiver. If you cannot eliminate the interference, the FCC requires that you stop using the radio. Hazardous Environments: Do not operate the radio in hazardous environments. Under certain conditions, radios can interfere with blasting operations and may cause an explosion. Turn your radio OFF to prevent accidental transmission when in a blasting area or in areas posted: "Turn off two-way radio. " Construction crews often use remote control RF devices to set off explosives. Care and Safety: To clean the radio, use a soft cloth dampened with water. [. . . ] The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements and should be avoided. For more information about RF exposure, please visit the FCC web site at www. fcc. gov. ONE YEAR LIMITED WARRANTY Important: Evidence of original purchase is required for warranty service. WARRANTOR: UNIDEN AMERICA CORPORATION ("Uniden") ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail owner, this Uniden Product to be free from defects in materials and craftsmanship with only the limitations or exclusions set out below. WARRANTY DURATION: This warranty to the original user shall terminate and be of no further effect 12 months after the date of original retail sale. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE UNIDEN GMR1235-2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual UNIDEN GMR1235-2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.