User manual UNIDEN BC60XLT-1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual UNIDEN BC60XLT-1. We hope that this UNIDEN BC60XLT-1 user guide will be useful to you.


UNIDEN BC60XLT-1 : Download the complete user guide (3799 Ko)

Manual abstract: user guide UNIDEN BC60XLT-1

Detailed instructions for use are in the User's Guide.

[. . . ] (The frequency coverage is not totally continuous from 29 MHz to 512 MHz. ) Chain Searching ­ You can define five different personal search bands, and search up to all five chain locations at once. Priority Channel Scanning ­ Allows you to designate a priority channel which is monitored every two seconds when Priority Scanning is selected. Memory Backup ­ Frequencies programmed in channels are retained in memory. If power is completely disconnected, the frequencies are retained for one hour. [. . . ] After or you finish programming a channel, press to go to the next higher channel. Channels with no frequencies are automatically locked out. Record channels and frequencies in some convenient place in case the scanner memory is lost. 15 Scanning When you turn on the power, the BC60XLT-1 automatically starts in the Scan mode. You can designate any of the 30 available channels as your Priority Channel. Press . Note: If you have locked out the priority channel, this message appears when you select Priority Mode. Press again at anytime to deactivate Priority Scan. 21 Changing the Priority Channel You cannot eliminate the Priority Channel, but you can change it to any other of the 30 available channels. Then press again. 3. Press and hold for two seconds to designate this channel as your new Priority Channel. Two beeps indicate that the Priority Channel is changed. 22 Chain Search Use Chain Search to find active frequencies in your area. You can search up to all five personal bands or turn off those bands you don't want to hear. This gives you flexibility of searching for any channel between 29 and 512 MHz, as long as they are within the 10 frequencies bands covered by the BC60XLT-1. See the table on page 3, the Technical Specifications on page 34, or the table on the back of the BC60XLT-1. Setting a Search Range An error message displays when R is pressed and you have not either specified a search range in at least one Chain Search band --OR-- If you attempt to turn off all Personal Chain Search bands. The Error message turns off automatically and Chain 1 is selected when all search locations are empty. Press M to return to normal scan, or press s to select the band you want to program. 23 To program a frequency range into one of the five personal Chain Search bands, follow these steps: 1. Press s until the search location you want appears in the display. 2. Enter lower limit of the search band. Then press E. Note: The display alternates between the upper and lower ranges. 3. Enter upper limit of the search band. Then press E. 24 Note: The display alternates between the upper and lower ranges. If you program the wrong limit, press 0 and E, then press 0 and E again to erase the error and reset the limits to zero. Either press R to begin your search. Note: Your scanner searches each selected Personal Chain Search band. Other bands which are programmed and selected are displayed but do not flash. --OR-- Press s to move to the next chain location. Note: You can press the Chain Search band number, followed by s, to access the location directly. 25 5. To turn off a Chain Search band during search scanning, press its location number. For example, (a) if Chain Search locations 1, 2 and 3 are selected, (b) press 3 to turn off band three so that it's not scanned during your search. Search Hold Feature 1. Press U or D at anytime to stop the search. 2. Press U to move to the next higher frequency --OR-- (See Step 3) 3. Press D to move down to the previous frequency. 4. Press R to resume searching. Note: The search continues toward either the upper or lower search limit, depending on which direction key (U or D) was pressed last. 26 Channel Skip If a particular channel continues to interrupt search scanning, it is possible to set your scanner to skip the frequency. If your scanner stops while searching, press N to lockout the frequency from the search range. Note: You can program 10 skip frequencies. [. . . ] THE LIMITED WARRANTY SET FORTH ABOVE IS THE SOLE AND ENTIRE WARRANTY PERTAINING TO THE PRODUCT AND IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES OF ANY NATURE WHATSOEVER, WHETHER EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow this exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. LEGAL REMEDIES: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE UNIDEN BC60XLT-1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual UNIDEN BC60XLT-1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.