User manual ULINE ORIGINS 75R

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ULINE ORIGINS 75R. We hope that this ULINE ORIGINS 75R user guide will be useful to you.


ULINE ORIGINS 75R : Download the complete user guide (374 Ko)

You may also download the following manuals related to this product:

   ULINE ORIGINS 75R INSTALLATION GUIDE (599 ko)
   ULINE ORIGINS 75R SUPPLEMENTARY GUIDE (88 ko)

Manual abstract: user guide ULINE ORIGINS 75R

Detailed instructions for use are in the User's Guide.

[. . . ] User's Manual ICE-MAKERS, COMBOS AND REFRIGERATORS U-LINE CORPORATION LIMITED WARRANTY U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase; and warrants the sealed system (consisting of the compressor, the condenser, the evaporator, the hot gas bypass valve, the dryer and the connecting tubing) in each U-Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase. During the initial one-year warranty period for all U-Line products U-Line shall: (1) at U-Line's option, repair any product or replace any part of a product that breaches this warranty; and (2) for all Marine, RV and Domestic U-Line products sold and serviced in the United States (including Alaska and Hawaii)and Canada, U-Line shall cover the labor costs incurred in connection with the replacement of any defective part. During years two through five of the warranty period for the sealed system, U-Line shall:. (1) repair or replace any part of the sealed system that breaches this warranty; and (2) for all Marine, RV and Domestic U-Line products sold and serviced in the United States (including Alaska and Hawaii)and Canada, U-Line shall cover the labor costs incurred in connection with the replacement of any defective part of the sealed system. [. . . ] Remove four plastic plugs in hinge holes, top of cabinet, opposite side (see Figure 22). Remove pivot screw from top hinge, invert screw and reinstall pivot screw in top hinge. Remove bottom hinge from cabinet (4 screws) and screws on opposite side of cabinet (see Figure 24). Remove pivot screw from bottom hinge, invert screw and reinstall pivot screw in hinge (see Figure 21). Figure 24 16 6. 7. UL128 8. Install bottom hinge on cabinet, opposite side, aligning flat edge of hinge with outer edge of unit. Relocate plastic spacer/ bushing on bottom of door to opposite side, and place door on bottom hinge pin (see Figure 20). Align flat edge of top hinge with outer edge of unit and fasten upper hinge to unit (4 screws). Replace four plastic plugs removed in step 5 into holes on top of unit. Reinstall grille (1 screw). 17 User's Manual REVERSING A STAINLESS STEEL DOOR Stainless Steel models are field reversible for left or right hand opening. The door opening is easily reversed by moving the hinge hardware to the opposite side (see Figure 26) as follows: 1. Assure gasket is firmly in contact with cabinet all the way around the door (no gaps). Tighten top hinge screws. 18 NOTE When inspecting door alignment, make sure that the light switch bracket (where equipped) makes contact with the light switch plunger (see Figure 27). Also, make sure that the door gasket is not pinched too tightly on the hinge side of the door. UL130 Figure 27 CUSTOM DOOR PANEL INSERT INSTALLATION A custom door panel insert can be installed in most U-Line units. The maximum panel thickness where inserted into the door reveal (channel) is 1/4" thick. For raised panels, the depth of the reveal is 1/4" on the sides and bottom, and 1/2" on the top. The size of the door panel insert is shown below: The door panel insert must not weigh more than 20 lbs. Custom Door Panel Dimensions B Model BI-95 BI-98 75 Series 75 SS 29 Series 15 Series 15 SS A 13­15/32" 15­15/16" 28­5/32" 29­13/32" 21­13/32" 28­5/32" 29­13/32" B 12­15/16" 13­15/16" 22­15/16" 22­15/16" 19­13/16" 13­15/16" 13­15/16" A SS - Stainless steel units NOTE Model SP18 does not accept custom door panels. 19 User's Manual Install the insert as follows: ! Insert edges may be SHARP!Start in the middle and pull outward, moving toward the edge (see Figure 29). Pull handle up and off. Figure 29 5. UL132 Figure 30 20 NOTE Use care not to bend light switch bracket (where installed), located on door bottom when installing door insert. Holding door gasket out of the way, replace handle on door making sure it is seated properly on insert and that screw holes line up. Starting at the center and working outward, push door gasket into place on door. 8. Place door on bottom hinge pin and install upper hinge screw (see Figure 28). [. . . ] However, this interval may not be adequate in periods of high humidity or heavy usage. Defrost your unit whenever the frost thickness is 1/4" or greater. To defrost, turn the unit OFF, remove cubes and prop door open at least two inches. NOTE Frost free units will never need defrosting. However, in extremely high humidity or during periods of unusually high usage, minimal manual defrosting may be required. STORAGE If the unit is to be stored or not used for extended periods, it will be necessary to drain the system of water. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ULINE ORIGINS 75R




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ULINE ORIGINS 75R will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.