User manual ULINE ECHELON CLR2060

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ULINE ECHELON CLR2060. We hope that this ULINE ECHELON CLR2060 user guide will be useful to you.


ULINE ECHELON CLR2060 : Download the complete user guide (2007 Ko)

You may also download the following manuals related to this product:

   ULINE ECHELON CLR2060 INSTALLATION GUIDE (509 ko)
   ULINE ECHELON CLR2060 SUPPLEMENTARY GUIDE (142 ko)

Manual abstract: user guide ULINE ECHELON CLR2060

Detailed instructions for use are in the User's Guide.

[. . . ] É c h e l o nTM U S E R M A N U A L U-LINE CORPORATION LIMITED WARRANTY U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase; and warrants the sealed system (consisting of the compressor, the condenser, the evaporator, the hot gas bypass valve, the dryer and the connecting tubing) in each U-Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase. During the initial one-year warranty period for all U-Line products U-Line shall: (1) at U-Line's option, repair any product or replace any part of a product that breaches this warranty; and (2) for all Marine, RV and Domestic U-Line products sold and serviced in the United States (including Alaska and Hawaii)and Canada, U-Line shall cover the labor costs incurred in connection with the replacement of any defective part. During years two through five of the warranty period for the sealed system, U-Line shall:. (1) repair or replace any part of the sealed system that breaches this warranty; and (2) for all Marine, RV and Domestic U-Line products sold and serviced in the United States (including Alaska and Hawaii)and Canada, U-Line shall cover the labor costs incurred in connection with the replacement of any defective part of the sealed system. [. . . ] For recessed installations, allow extra water supply line length to provide slack for easy removal from the recessed area (see Figure 9). This will also safeguard against kinking the line. UL134 Figure 6 5. Carefully bend the water supply line into position and connect the line to the solenoid valve (see Figures 7 and 8). Avoid kinking the water supply line. POWER CORD UL200 Figure 9 WATER LINE UL201 Figure 7 12 NOTE After completing the installation, turn on the water and recheck water and drain connection for leaks. Do NOT use thread sealing compound or tape. NOTE Route the water supply line through the clip on the sidewall of the unit in such a way as to prevent the line from coming in contact with any internal components other than the solenoid valve (see Figure 5). A water supply line contacting an internal component or cabinet wall may cause excessive noise during operation or damage to the line. Allow at least 1-1/2 inches clearance behind the unit for electrical, water supply and drain connections. LEVELING THE UNIT NOTE It is extremely important that the unit is level. This can cause a reduction in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt prematurely. Remember that floors near drains have a tendency to slope towards the drain. Use a level to check the levelness of the ice maker from front to back and from side to side (see Figure 10). If the ice maker is not level, adjust the feet on the corners of the unit as necessary (see Figure 11). 13 User's Manual CHECK LEVEL UL314 Figure 10 TURN FOOT TO ADJUST UL205A Figure 11 3. Check the levelness after each adjustment and repeat the previous steps until the unit is level. REVERSING THE DOOR All U-Line units (except Stainless Steel models) may be left or right hand opening. The door opening is easily reversed by moving the hinge hardware to the opposite side (see Figure 12). To reverse the door: UL318B Figure 12 14 1. Remove top hinge screw pin (7/64" Allen wrench) from 3. Remove door by tilting forward and lifting off bottom hinge pin. Remove top hinge (3 screws), reinstall hinge screw pin, and remount on opposite side BOTTOM (see Figure 15). HINGE SCREW PIN UL313 Figure 15 UL310 Figure 13 2. Remove plastic screw plugs (3 each, top and bottom) from new hinge location. Do not discard (see Figure 14). 4. Remove the two door closer inserts from the existing bottom hinge and install as shown on the new bottom hinge (see Figure 16). SCREW PLUGS DOOR CLOSER INSERTS UL308 UL312 Figure 14 Figure 16 15 User's Manual 5. Remove existing bottom hinge (3 screws) and remount on opposite side TOP Remove hinge screw pin. With bottom of door facing up, remove pivot plate (2 screws), flip over, and remount on opposite side of door (see Figure 17). UL319 Figure 17 7. Holding door upright with top of door tilted forward, place hole of door pivot plate on bottom hinge screw pin (see Figure 18). Tilt top of door into position in top hinge and install top hinge screw pin. [. . . ] Remove the overflow tube by lifting it up while using a slight back and forth motion to loosen it from the drain hole (see Figure 27). Replace the overflow tube after all of the water has drained from the reservoir. When water begins to flow over the evaporator (approximately 3 minutes), add one package of U-Line Ice Machine cleaner to the water reservoir. When the self-cleaning process stops (approximately 45 minutes) it may be desirable to clean the storage bin at this time (see INTERIOR CLEANING). 10. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ULINE ECHELON CLR2060




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ULINE ECHELON CLR2060 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.