User manual TOSHIBA TCS-NET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA TCS-NET. We hope that this TOSHIBA TCS-NET user guide will be useful to you.


TOSHIBA TCS-NET : Download the complete user guide (2844 Ko)

Manual abstract: user guide TOSHIBA TCS-NET

Detailed instructions for use are in the User's Guide.

[. . . ] E05-412 TCS-NET Air-Conditioning Control System [Setting File Creation Software] User's Manual Introduction This is the User's Manual for the Setting File Creation Software (here after referred to as the "software") for the Air-conditioning Control System. · Setting File Creation Software Ver 2. 00 Revision 02 * This Software (Ver 2. 0 Rev 02) is not compatible with Ver 1. 0 · "Windows 2000" and "Windows XP" are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries. · "Microsoft Excel" is a trademark or registered trademark of Microsoft Corporation in the United States and other countries. · All company names and product names appearing in this manual are the trademark or registered trademark of their respective holders. [. . . ] 3 Locking (OFF to ON) OFF OFF OFF + [ON/OFF] switching prohibited OFF Unlocking (ON to OFF) No action [ON/OFF] switching prohibition reset [ON/OFF] switching prohibition reset No action (10) Energy monitoring Choose "1: Valid" or "0: Void" for whether to use energy monitoring. (11) Power meter pulse constant setting Choose "1: Valid" or "0: Void" for whether to input power meter pulse constant in "WHM_CH. DEF". (12) Stand-by power counting Specify "Outdoor refrigerant system heater capacity kW" calculation method in the "Indoor unit group definition" sheet. 1: Proportional sharing on indoor unit horse power codes : Calculated using the proportional sharing method. 2: Equal sharing on indoor units Qty : Calculated using the equal sharing method. (13) kW conversion coefficient (input prohibited) This coefficient is used when calculating outdoor refrigerant system heater capacity kW of indoor unit sw using the proportional sharing on indoor unit horse power codes. Do not change this value as it is fixed to 0. 75. 27 (14) Whole building display mode Specify a display unit when [Whole building] button is pressed. Choose "0: block, " "1: tenant, " "2: area, " or "3: R. C. (15) Number of block display buttons Specify the number of horizontal buttons in the block display mode. (16) Number of tenant display buttons Specify the number of horizontal buttons in the tenant display mode. (17) Number of area display buttons Specify the number of horizontal buttons in the area display mode. group/indoor display buttons Specify the number of horizontal buttons in the R. C. group/indoor" or "0: area unit" for schedule setting unit. (20) Filter sign display mode Choose "1: display" or "0: not display" for filter sign display mode. (21) Backlight save count (minutes) Set backlight save count on the Touch Screen Controller screen in units of minute. 6-1-3 Buttons [Setting File create] Used to output setting files. Press this button after entering all data on every sheet to execute the creation of a setting file. 28 6-2 "System equipment configuration" sheet This sheet is used to specify the number of the following interfaces connected to each Intelligent Server. Input correct number of interfaces beforehand in the "System Setting" sheet as the system equipment configuration table is automatically created based on the "Intelligent Server Qty" data in the "System Setting" sheet. 6-2-1 Window Image 6-2-2 Window Description (1) TCS-Net Relay Interface Qty (for use in Japan and overseas) Specify the number of TCS-Net Relay Interfaces connected to each Intelligent Server. (2) Digital I/O Relay Interface Qty (for overseas use) Specify the number of Digital I/O Relay Interfaces connected to each Intelligent Server. (3) Energy Monitoring Relay Interface Qty (for overseas use) Specify the number of Energy Monitoring Relay Interfaces connected to each Intelligent Server. 6-2-3 Buttons No buttons are provided on this sheet. 29 6-3 "Address Setting" sheet This sheet is used to specify the interface number of each device to be connected. Input correct data beforehand in the "System Setting" and "System equipment configuration" sheets as the address setting table is automatically created based on the data entered in these sheets. 6-3-1 Window Image 6-3-2 Window Description · The uppermost table (1) Equipment category (input prohibited) Equipment names are listed. · I/O kit table (for use in Japan) (Displayed when a number more than 0 is set for "I/O kit Qty" in the "System Setting" sheet. ) (1) Equipment category (input prohibited) "I/O kit" is displayed. Though this setting is not used, no setting file can be output if this item is left blank. 30 · Energy Monitoring Relay Interface table (for use in Japan) (Displayed when a number more than 0 is set for "Energy Monitoring Relay Interface Qty" in the "System Setting" sheet. ) (1) Equipment category (input prohibited) "Energy Monitoring Relay Interface" is displayed. [. . . ] · "Total outdoor unit crankcase heater capacity (kW)" Input "0" for multi-system models. For Digital Inverter/Super Digital Inverter models, input the total outdoor unit crankcase heater capacity in kW. · "Indoor unit Qty" Input "1" for single indoor unit model name. For indoor units with set model name, input the number of indoor units defined by the set model name. 60 · "Outdoor unit Qty" Input "0" for multi-system models. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA TCS-NET




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA TCS-NET will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.