User manual TOSHIBA TCB-PCMO4E INSTALLATION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA TCB-PCMO4E. We hope that this TOSHIBA TCB-PCMO4E user guide will be useful to you.


TOSHIBA TCB-PCMO4E INSTALLATION MANUAL: Download the complete user guide (456 Ko)

Manual abstract: user guide TOSHIBA TCB-PCMO4EINSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Observe them without fail. Understand the following details (indications and symbols) before reading the body text, and follow the instructions. The meanings of indications [PCB Installation Position] SMMS-i MMY-MAP080 to 120 MMY-MAP140, 160 SMMS-i Connector Positions CN510 (white) CN508 (red) About Switching of Processing of Indoor Unit Operation State [Setting can be changed only on the SMMS-i. ] Processing of the operation state can be switched for indoor units in a mode other than the selected operation mode by setting the jumper lead (J01) of the header outdoor unit interface PCB. Jumper lead Details of Processing Unallowed indoor units in a mode other than the selected operation mode are not treated as priority (thermo OFF state). [. . . ] Ask customer to keep this Manual at accessible place for future reference. Indoor units in a mode other than the selected operation mode are forcibly switched to the selected operation mode. PC board selection mode Normal Cool Heat , , Remote control operation/display can be selected When using the remote control, (mode Only , , or can be select control) selected indicator is displayed. Only or can be selected , or WARNING · Only a qualified installer or qualified service person is allowed to do installation work. If installation is carried out by an unqualified individual, fire or electric shock may result. · Perform installation work reliably according to this installation manual. Incomplete installation may cause electric shock, fire or abnormal operation. · Electrical work must be performed by a qualified installer or qualified service person in accordance with this installation manual. The work must satisfy all local, national and international regulations. · Connect the specified wires firmly and clamp them securely so that external force applied to the wires does not affect the connector pins. Improper wire connection or clamping may result in fire or malfunction. · Do not disassemble, modify, repair or move the product yourself. · Ask a qualified installer or qualified service person to do any repairs or to move the product. Optional PCB 6 5 Input wiring CAUTION Be sure to provide no-voltage pulse contacts for each terminal. Do not turn SW1 and SW2 ON simultaneously Model : MiNi-SMMS Night operation (sound reduction) control Model : SMMS-i, SMMS, SHRM, MiNi-SMMS Functions Operation The rotation speed of the compressor and fan can be restricted during input of the night time signal to reduce noise by connecting to the interface PCB of outdoor units. The jumper lead is not switched. Unallowed indoor units in a mode other than the selected operation mode are not treated as priority (thermo OFF state). (Unallowed indoor units) Operation Mode Cooling unit Heating unit Air blow unit Operation State Air blow operation at blow rate set on remote control Air blow operation at super-slow blow rate Regular air blow operation at blow rate set on remote control Remote control , indicator is displayed. SMMS, SHRM Optional PCB 1 External View 55. 5 45. 5 NCC-1214 The outdoor unit connection is for the header unit (U1). Header outdoor unit Outdoor unit interface PCB CN508 TOSHIBA 10 TCB-PCMO1 TCB-PCMO1E Terminal block (M3) Outdoor unit interface PCB Interface PCB (outdoor unit control PCB) Connection cable ( 1 ) Locally procured Optional PCB TB1 COM PJ17 COOL HEAT Model : SMMS, SHRM The jumper lead is not switched. [. . . ] board CN510 (white) CN508 (red) CN509 (black) CN512 (blue) Outdoor unit interface PCB Connection cable ( 1 ) Optional PCB TB1 COM PJ17 COOL HEAT SW2 SW1 · Optional PCB (both side) Cooling (SW1) figure below. Install the "optional PCB" at the specified location inside the electrical components box using the fixing support. There are four mounting holes for the fixing support ( 2 ) at specified locations inside the electrical components box. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA TCB-PCMO4E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA TCB-PCMO4E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.