User manual TOSHIBA T1-16S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA T1-16S. We hope that this TOSHIBA T1-16S user guide will be useful to you.


TOSHIBA T1-16S : Download the complete user guide (1635 Ko)

Manual abstract: user guide TOSHIBA T1-16S

Detailed instructions for use are in the User's Guide.

[. . . ] 6F3B0253 UM-TS01-E031 PROGRAMMABLE CONTROLLER PROSEC T1- 16S USER'S MANUAL - Basic Hardware and Function - TOSHIBA CORPORATION 6F3B0253 Important Information Misuse of this equipment can result in property damage or human injury. Because controlled system applications vary widely, you should satisfy yourself as to the acceptability of this equipment for your intended purpose. In no event will Toshiba Corporation be responsible or liable for either indirect or consequential damage or injury that may result from the use of this equipment. No patent liability is assumed by Toshiba Corporation with respect to use of information, illustrations, circuits, equipment or examples of application in this publication. [. . . ] If RW08 is 300, the data of D0300 is stored in YW10. 136 T1-16S User's Manual 6F3B0253 7. Instructions FUN 019 Expression Input -[ A+1A MOV B+1B ]- Output DMOV Double-word data transfer Function When the input is ON, the double-word (32-bit) data of A+1A is stored in double-word register B+1B. The data range is -2147483648 to 2147483647. Execution condition Input OFF ON Operation No execution Execution Output OFF ON Operand Name X A Source B Destination Y Device R S T. XW YW RW SW T C D Constant Index I J K Example When R011 is ON, a double-word data of D0101D0100 is stored in RW17RW16 and the output is turned ON. If D0101D0100 is 1234567, the data 1234567 is stored in RW17RW16. Basic Hardware and Function 137 6F3B0253 7. Instructions FUN 020 Expression Input -[ A NOT B ]- Output NOT Invert transfer Function When the input is ON, the bit-inverted data of A is stored in B. Execution condition Input OFF ON Operation No execution Execution Output OFF ON Operand Name X A Source B Destination Y Device R S T. XW YW RW SW T C D Constant Index I J K Example When R010 is ON, the bit-inverted data of RW30 is stored in D0200 and the output is turned ON. If RW30 is H4321, the bit-inverted data (HBCDE) is stored in D0200. F E D C B A 9 8 7 6 5 4 3 2 1 0 RW30 0100001100100001 4 3 2 Bit-invert 1 F E D C B A 9 8 7 6 5 4 3 2 1 0 D0200 1011110011011110 B C D E 138 T1-16S User's Manual 6F3B0253 7. Instructions FUN 022 Expression Input -[ A XCHG B ]- Output XCHG Data exchange Function When the input is ON, the data of A and the data of B is exchanged. Execution condition Input OFF ON Operation No execution Execution Output OFF ON Operand Name X A Operation data B Operation data Y Device R S T. XW YW RW SW T C D Constant Index I J K Example When R005 is ON, the data of RW23 and D0100 is exchanged. If the original data of RW23 is 23456 and that of D0100 is 291, the operation result is as follows. RW23 D0100 23456 291 RW23 D0100 291 23456 Before operation After operation Basic Hardware and Function 139 6F3B0253 7. Instructions FUN 024 Expression Input -[ A TINZ (n) B ]- Output TINZ Table initialize Function When the input is ON, the data of A is stored in n registers starting with B. The allowable range of the table size n is 1 to 1024 words. Execution condition Input OFF ON Operation No execution Execution Output OFF ON Operand Name X A Source n Table size B Start of destination Y Device R S T. XW YW RW SW T C D Constant Index I J K 1 - 1024 Example When R010 is ON, a constant data (0) is stored in 100 registers starting with D0200 (D0200 to D0299) and the output is turned ON. Constant 0 D0200 D0201 D0202 0 0 0 100 registers D0299 0 140 T1-16S User's Manual 6F3B0253 7. Instructions FUN 025 Expression Input -[ A TMOV (n) B ]- Output TMOV Table transfer Function When the input is ON, the data of n registers starting with A are transferred to n registers starting with B in a block. The allowable range of the table size n is 1 to 1024 words. Execution condition Input OFF ON Operation No execution Execution Output OFF ON Operand Name X A Start of source n Table size B Start of destination Y Device R S T. XW YW RW SW T C D Constant Index I J K 1 - 1024 Example When R010 is ON, the data of D0500 to D0509 (10 registers) are block transferred to D1000 to D1009, and the output is turned ON. D0500 D0501 D0502 1111 2222 3333 D1000 D1001 D1002 1111 2222 3333 Block transfer 10 registers D0509 12345 D1009 12345 Note · The source and destination tables can be overlapped. Basic Hardware and Function 141 6F3B0253 7. Instructions FUN 026 Expression Input -[ A TNOT (n) B ]- Output TNOT Table invert transfer Function When the input is ON, the data of n registers starting with A are bit-inverted and transferred to n registers starting with B in a block. The allowable range of the table size n is 1 to 1024 words. Execution condition Input OFF ON Operation No execution Execution Output OFF ON Operand Name X A Start of source n Table size B Start of destination Y Device R S T. [. . . ] A function instruction which is not supported type in the by the T1-16S is programmed. Program A basic ladder instruction which is not type supported by the T1-16S is programmed. (Error down) Reload the program and execute EEPROM write operation again. Program Address A FOR-NEXT loop is programmed inside type in the other FOR-NEXT loop. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA T1-16S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA T1-16S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.