User manual TOSHIBA SL-9000-ESB

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA SL-9000-ESB. We hope that this TOSHIBA SL-9000-ESB user guide will be useful to you.


TOSHIBA SL-9000-ESB : Download the complete user guide (997 Ko)

Manual abstract: user guide TOSHIBA SL-9000-ESB

Detailed instructions for use are in the User's Guide.

[. . . ] TEC Electronic Computing Scale SL-9000-ESB SERIES Owner's Manual Safety Summary Safety Summary Personal safety in handling or maintaining the equipment is extremely important. Warnings and Cautions necessary for safe handling are included in this manual. All warnings and cautions contained in this manual should be read and understood before handling or maintaining the equipment. If a fault occurs that cannot be rectified using the procedures described in this manual, turn off the power, unplug the machine, then contact your authorized TOSHIBA TEC representative for assistance. Meanings of Each Symbol This symbol indicates warning items (including cautions). [. . . ] Menu Group: 1 Item No. :8 You can set the maximum 49 kinds of grade lines (max. 32 characters/line), and call one of them to print it on the label. <MENU> Group 1 8 Enter the grade line#. 32 chars. /line) (Refer to NOTE 2) ENTER PROG. <MENU> Group 1 Main <MENU> ESC. NOTES: 1. Refer to page 11-4, for information regarding how to enter the Grade Line. 11-16 11. PROGRAMMING PROCEDURES 11. 9 SPEED KEY SETTING 11. 9 SPEED KEY SETTING Normal Mode Menu Group: 1 Item No. : 9 ESB Limited Spec. Mode Item No. : 8 The SL-9000 has a maximum of 70x2 speed keys which are very convenient to call PLUs quickly. (Refer to page 5-3 regarding the Key Layout. ) i <MENU> Group 1 9 Enter the Speed Key number (# 1~70 X 2) NEXT or PLU ENTER Select the 1st half or the 2nd half of the speed keys. i Enter the PLU#. 6 dig. ) ENTER PROG. <MENU> Group 1 Main <MENU> Enter the speed key number. ESC. Setting Department/Vendor Number <MENU> Group 1 9 AUTO CODE Enter a default department #. (1 ~ 99) ENTER PROG. <MENU> Group 1 Main <MENU> Selecting items to be assigned to speed keys. (PLU #/VENDOR #/DEPT #) ESC. · Department Number When initial set #10-6 is set to "1", the six-digit PLU# is divided into two; the upper two digits are assigned to department #, and the lower four digits to PLU. The department # is automatically added in front of four-digit PLU# and treated as a six-digit PLU#. In case of "PROG. ", "Report", and "Reset" modes, PLU# is treated as a six-digit number. Consequently the four-digit PLU# is available only in "REG. ", "M. DOWM", and "REWRAP" modes. NOTE: The default Dept. No. · Vendor Number Vendor numbers can be set when the Initial Setting #11-1 is set to 1. Vendor numbers are assigned to the speed keys in two ways: 1 Individual vendor number: 00-39 Vendor# is assigned to the speed keys one by one. 2 Group vendor number: 0-, 1-, 2- and 3Maximum 10 vendor numbers can be assigned to one speed key, resulting in 4 speed keys in total. When assigning group vendor numbers to the speed keys, enter the first digit of the vendor key (0, 1, 2 or 3) plus a bar (-). Vendor numbers can be called whichever half of the speed keys are selected. PROGRAMMING PROCEDURES 11. 10 PRINT FORMAT 11. 10 PRINT FORMAT Normal Mode Menu Group: 2 Item No. : 0 ESB Limited Spec. Mode Item No. : 3 The SL-9000 can memorize 5 different print formats. After print formats are set, you can call them by entering the print format number. <MENU> Group 2 0 Select the print format # which allocates the label format # by the NEXT PLU key or ­ key. (Refer to Table 2) j CHANGE PLU Issue method On-demand FEED SET NEXT TEST Is print position correct? Correct Batch Select "SENSIBILITY ADJUST" by pressing the key. When Batch Printing with backing paper is selected, the sensitivity of the label sensor will be set by pressing the SET NEXT key before issuing label. Incorrect Select the Item for adjustment. CHANGE PLU 1 gradation = 0. 154mm (1 dot) 1 gradation = 0. 462mm (3 dots) 1 gradation = 0. 462mm (3 dots) Only when using the bar code change label with pre-feed area. [. . . ] If you cannot solve the problem with the following solution instruction, do not attempt further trouble shooting, by yourself. Turn the power off, unplug the printer, then contact TOSHIBA TEC Authorized Service representative for assistance. Do not attempt to repair or adjust alone, because electrical equipment is dangerous Programming Mode Message DATA ENTRY ERROR MEMORY FULL DUPLICATE PLU PLU NOT FOUND CHAR. After that change the capacity of RAM and load the data to the unit. PRT FAILURE 16-1 16. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA SL-9000-ESB




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA SL-9000-ESB will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.