User manual TOSHIBA SATELLITE M30

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA SATELLITE M30. We hope that this TOSHIBA SATELLITE M30 user guide will be useful to you.


TOSHIBA SATELLITE M30 : Download the complete user guide (4420 Ko)

You may also download the following manuals related to this product:

   TOSHIBA SATELLITE M30 (5216 ko)
   TOSHIBA SATELLITE M30 (4174 ko)
   TOSHIBA SATELLITE M30 (4400 ko)
   TOSHIBA SATELLITE M30 (7788 ko)
   TOSHIBA SATELLITE M30 (4573 ko)
   TOSHIBA SATELLITE M30 (4218 ko)
   TOSHIBA SATELLITE M30 (5275 ko)
   TOSHIBA SATELLITE M30 (4384 ko)
   TOSHIBA SATELLITE M30 (6179 ko)
   TOSHIBA SATELLITE M30 (4675 ko)
   TOSHIBA SATELLITE M30 (5601 ko)
   TOSHIBA SATELLITE M30 (4821 ko)
   TOSHIBA SATELLITE M30 (5058 ko)
   TOSHIBA SATELLITE M30 (4855 ko)
   TOSHIBA SATELLITE M30 (4482 ko)

Manual abstract: user guide TOSHIBA SATELLITE M30

Detailed instructions for use are in the User's Guide.

[. . . ] The warranty contained in the contract between the parties is the sole warranty of Toshiba International Corporation's UPS Division, and any statements contained herein do not create new warranties or modify the existing warranty. Any Electrical or mechanical modifications to this equipment without prior written consent of Toshiba International Corporation will void all warranties and may void UL/CUL listing. Unauthorized modifications may also result in equipment damage, personal injury, or loss of life. UNINTERRUPTIBLE POWER SYSTEM If additional information or technical assistance is required call Toshiba's Customer Service Department toll free at 1-800-231-1412, or write to: Toshiba International Corporation, 13131 W. Unless otherwise specified on the warranty card, the warranty period for the UPS or UPS part is 36 months from the shipment date (see TIC bill of lading). Unless otherwise specified on the warranty card, the warranty period for a UPS battery is 24 months from the shipment date (see TIC bill of lading). [. . . ] 11) The heat sink and other components may become extremely hot to the touch. 12) Warning signs should be placed on or near the load to let people know that the load is being powered by the UPS. 13) Additional warnings and notifications shall be posted at the equipment installation location as deemed required by Qualified Personnel. CAUTION CAUTION When the UPS is in the Inverter mode, turning the breaker to the OFF position will cause the unit to go into the battery backup mode. The unit must be in Bypass mode and then the breaker turned to the OFF position for the UPS to shut down power to the load. Do not EPO (Emergency Power OFF) the UPS and then reset the breaker until the UPS has been fully discharged. The UPS could be damaged if the unit is not fully powered down before the breaker is reset. ABIHSOT 17 4. 0 UPS Connections 4. 1 UPS Power and Control Connections The following illustration shows the wiring connections to the input and output termination points and the Control Circuit Terminal Blocks for the 4200FA 75/80 kVA UPS. ABIHSOT 18 4. 1. 1 Recommended Wire Size and Tightening Torque for UPS Input/Output Terminals Minimum/Maximum Wire Size and Tightening Torque of UPS Input and Output Terminals Main Input & Bypass Input 208VAC 380, 400, 415VAC 480VAC 600VAC AWG (H1 ­ H3, BYP1, BYP2, BYP3) 300MCM to 500MCM 2/0 to 500MCM 1/0 to 500MCM 1/0 to 500MCM Output 208V/120VAC AWG (L1, L2, L3) 300MCM to 500MCM Battery Circuit 288VDC Nominal 400MCM to 600MCM Input/Output Ground 2 minimum (see note 1) All wire sizes are per NEC Use copper wiring with at least 90°C rated insulation Neutral Conductors are rated @ 1. 73 or 200% of phase conductors, per NEC Note 1: Use a UL listed lug suitable for the wire size used. Note 2: Use tightening torque recommended by manufacturer of lug used. ABIHSOT AWG (POS, NEG) AWG (GND) 19 AWG (N, BYPN) 400MCM to 500MCM 400MCM to 500MCM 400MCM to 500MCM 400MCM to 500MCM Tightening Torque (in-lbs. ) 375 375 375 375 AWG (OUTN) 400MCM to 500MCM Tightening Torque (in-lbs. ) 375 Tightening Torque (in-lbs. ) 500 Tightening Torque (in-lbs. ) (see note 2) 4. 1. 2 Power Connection Cable Routing 1) Use separate metal conduits for routing the input power, output power, battery, and control circuits. 2) A separate ground cable should be run inside of the conduit with the input power, output power, and control circuits. 3) Always ground the unit to prevent electrical shock and to help reduce electrical noise. 4) Follow wire size and tightening torque recommendations provided in this manual. CAUTION THE METAL OF A CONDUIT IS NOT AN ACCEPTABLE GROUND Single Input UPS with input transformer. Shown with bottom cable entry configuration. ABIHSOT 20 Dual Input UPS with input transformer. 2. 5 1. 73 times line rating 1. 5% max (linear load) Automatic transfer to bypass, then retransfer to inverter AC/DC/AC: 87% typical; DC/AC: 90% typical 40, 000Btu/hr (10kcal·kg/hr) 75 dB (A) at 1 meter from the units front display 0 to 40°C; optimal operating temperature is 25°C Less than 90% RH (non-condensing) Less than 1000 meters Main Input Optional Bypass Input Battery Output Environment Items marked with an (*) are specified at rated conditions under balanced linear loads. (**) Battery backup time may vary depending on the operating conditions and ambient temperature at the installation site. An initial charge time of 24 hrs is necessary to obtain proper battery performance level before the unit is placed in operation. (***) At 6600-ft (2000 m) above sea level, output capacity should be derated by 3% (Consult factory for higher elevations). (****) Prolonged operation at this level requires derating of the maximum operating temperature to 35°C. ABIHSOT 32 5. 2 Specifications ­ 4200FA 75kVA without Internal Transformer Model Number Rated Output Capacity External Dimensions Weight Rated Voltage Voltage Variation Rated Frequency Number Phases / Wires * Power Factor Required Input Power Walk-in Function Inrush Current Current Limit * Harmonic Currents Rated Voltage Voltage Variation Rated Frequency Number Phases / Wires DC Nominal (Voltage Range) Float Charge (Regulation) Ripple Voltage **Rated Back-up Time Rated Charge Current Rated Voltage Rated Current Rated Power Factor Number Phases / Wires Voltage Regulation (phase-phase) Voltage Adjustment Range Phase Displacement Rated Frequency Frequency Regulation Frequency Synchronous Operation Range Frequency Slew Rate Voltage Transients (Recovery time: 50 mS) Inverter Overload Capacity Bypass Overload Capacity Crest Factor Neutral Line Conductor Harmonic Voltage Distortion Inrush Current protection Efficiency Heat loss to be removed Audible Noise Operating Temperature Operating Humidity Altitude *** T42F3F750@AXXN 75kVA 44 inch W x 31 inch D x 74 inch H 1560 pounds 208 Vac +10% to ­15% ; (-15% to ­30%) **** 50/60 Hz 3 Phase / 3 Wire Greater than 0. 99 when in inverter mode 70kW when in inverter mode From 20% to 100% over 5 seconds Less than 12 times rated current under synchronous operation 115% maximum Less than 3% THD @ = (X-n/a, F-208)Vac +10% to ­15% 50/60 Hz 3 Phase / 4 Wire + GND 288VDC (230 to 332VDC) 328VDC (±2%) with 2. 28V/cell 2% R. M. S. Refer to Battery System Manual 20. 0 Amps **** 208 / 120 VAC 208 Amps 0. 8 lagging 3-phase / 4 Wire + GND ± 2% (0-100% balanced load) ± 3% (0-100% unbalanced load) ± 5V Manually from front key pad ± 2° (0-100% balanced load) ± 4° (unbalanced load) 50 / 60 Hz ± 0. 1% in free running mode ± . 5/1. 0/1. 5 Hz (± 1. 0 Hz. std. ) switch selectable by qualified technician 1 Hz/s to 3 Hz/s ± 3% (100% load step change) ± 5% (loss or return of input voltage) ± 3% (transfer of bypass to inverter) 125% 30sec ; 150% 5sec 1000% 10msec; 125% 10min. 2. 5 1. 73 times line rating 1. 5% max (linear load) Automatic transfer to bypass, then retransfer to inverter AC/DC/AC: 87% typical; DC/AC: 90% typical 40, 000Btu/hr (10kcal·kg/hr) 75 dB (A) at 1 meter from the units front display 0 to 40°C; optimal operating temperature is 25°C Less than 90% RH (non-condensing) Less than 1000 meters Main Input Optional Bypass Input Battery Output Environment Items marked with an (*) are specified at rated conditions under balanced linear loads. (**) Battery backup time may vary depending on the operating conditions and ambient temperature at the installation site. An initial charge time of 24 hrs is necessary to obtain proper battery performance level before the unit is placed in operation. (***) At 6600-ft (2000 m) above sea level, output capacity should be derated by 3% (Consult factory for higher elevations). (****) Prolonged operation at this level requires derating of the maximum operating temperature to 35°C. ABIHSOT 33 5. 3 Specifications ­ 4200FA 80kVA with Internal Transformer Model Number Rated Output Capacity External Dimensions Weight Rated Voltage Voltage Variation Rated Frequency Number Phases / Wires * Power Factor Required Input Power Walk-in Function Inrush Current Current Limit * Harmonic Currents Rated Voltage Voltage Variation Rated Frequency Number Phases / Wires DC Nominal (Voltage Range) Float Charge (Regulation) Ripple Voltage **Rated Back-up Time Rated Charge Current Rated Voltage Rated Current Rated Power Factor Number Phases / Wires Voltage Regulation (phase-phase) Voltage Adjustment Range Phase Displacement Rated Frequency Frequency Regulation Frequency Synchronous Operation Range Frequency Slew Rate Voltage Transients (Recovery time: 50 mS) Inverter Overload Capacity Bypass Overload Capacity Crest Factor Neutral Line Conductor Harmonic Voltage Distortion Inrush Current protection Efficiency Heat loss to be removed Audible Noise Operating Temperature Operating Humidity Altitude *** T42#3F800@AXXN 80kVA 44 inch W x 31 inch D x 74 inch H 2150 pounds # = (B-208, H- 220, C-240, N-380, T-400/415, D-480, M-600 )Vac +10% to ­15% ; (-15% to ­30%) **** 50/60 Hz 3 Phase / 3 Wire Greater than 0. 99 when in inverter mode 75kW when in inverter mode From 20% to 100% over 5 seconds Less than 12 times rated current under synchronous operation 115% maximum Less than 3% THD @ = (X-n/a, F-208)Vac +10% to ­15% 50/60 Hz 3 Phase / 4 Wire + GND 288VDC (230 to 332VDC) 328VDC (±2%) with 2. 28V/cell 2% R. M. S. Refer to Battery System Manual 20. 0 Amps **** 208 / 120 VAC 223 Amps 0. 8 lagging 3-phase / 4 Wire + GND ± 2% (0-100% balanced load) ± 3% (0-100% unbalanced load) ± 5V Manually from front key pad ± 2° (0-100% balanced load) ± 4° (unbalanced load) 50 / 60 Hz ± 0. 1% in free running mode ± . 5/1. 0/1. 5 Hz (± 1. 0 Hz. [. . . ] CHARGE MODE SELECT EQUAL CHARGE>OFF ON >F1:DATA SET MODE >/:PRV/NEXT SCREEN Press the F1 key to display the following adjustment screen: CHARGE MODE SELECT EQUAL CHARGE>OFF ON >/:CHANGE DATA >ENTER:ACCEPT CHANGE Note: Please consult the factory when using this option. 6. 15. 8 Reset to Default Settings Press the MENU key to access the menu data screens. Press the Down arrow key to access the original factory default settings adjustment screen: MENU DATA RESET DATA INITIALIZATION >F1: TO ACCESS RESET >/:PRV/NEXT SCREEN Press the F1 key to display the following active adjustment screen: MENU DATA RESET DATA INITIALIZATION > MENU: NO DATA RESET >ENTER: ACCEPT CHANGE When the ENTER key is pressed the following factory defaults are reset: 1) Reset the voltage-reference setting to +0. Press the MENU key to abandon the operation and return to the menu data screen. ABIHSOT 55 6. 16 Overload Operation When the UPS is operating and an overload condition is detected the following screen is displayed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA SATELLITE M30




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA SATELLITE M30 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.