User manual TOSHIBA REMOTEYE II

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA REMOTEYE II. We hope that this TOSHIBA REMOTEYE II user guide will be useful to you.


TOSHIBA REMOTEYE II : Download the complete user guide (981 Ko)

Manual abstract: user guide TOSHIBA REMOTEYE II

Detailed instructions for use are in the User's Guide.

[. . . ] RemotEye II ® User Manual Document Number: 50024-008 November, 2005 About This Manual This manual was written by the TOSHIBA Engineering and Marketing Groups. These groups are tasked with providing technical documentation for the RemotEye II system. Every effort has been made to provide accurate and concise information to you, our customer. This manual provides information on how to safely install, operate, and maintain your RemotEye II system. [. . . ] Mail Daily Status Report At (hh:mm) This field allows the administrator to set the time to send a Daily Status report to select email address (Mail Accounts), The time is set in 24-hour format. Mail Account This field allows the administrator to set the email address of the recipients who will receive the events or/add the status reports. Description This field allows the administrator to set the description of the recipients. Mail Type This field allows the administrator to select the mail type None ­ Disable option to send email to recipients. Events ­ Current events will be sent to recipients 65 Daily Status ­ Daily History log and Events log will be sent to the email recipients at the designated time. Events with Status ­ Current events, History log and Events log will be sent to email recipients when events occurred EMD Configuration Comprehensive View This page gives a snapshot of all EMD parameters; the parameters will be updated automatically every 5 seconds. The text color of the parameter indicates its status based on the administratorconfigurable threshold. YELLOW : 'warning' status, RED : 'critical' status. The EMD provides the measurements for room temperature, room humidity, and two alarms. The warning/critical thresholds can be setup via the "EMD Setup" page. EMD Setup This page allows administrator to configure all necessary parameters of an EMD. Set Point The threshold of a sensor (temperature or humidity) will trigger an alarm, whenever the measurement is over (high) or under (low) the set point. The alarm can be configured to activate at warning or critical levels. If the checkbox is not filled, the threshold is disabled and the alarm will not be triggered. The valid range for the Temperature threshold setting is 5 to 65, and 5 to 95 for Humidity. Hysteresis A sensors value could be floating around its threshold triggering multiple alarms. Setting the hysteresis will help to prevent the alarm bouncing between active and inactive. For example, if the low warning threshold set point is 20 and hysteresis is 3, then the alarm will activate when the value reaches 20 but it will not become inactive again until the sensor value reaches 23. 66 For the contact alarm sensors, the hysteresis can be used to adjust the sensitivity of an alarm. The alarm will be active or inactive only after the alarm stays in the same state for the duration of the hysteresis value (in seconds). For example, if the hysteresis is 5 for an alarm, the alarm will NOT activate until the same state has persisted for 5 seconds. This ruling also applies in reverse so that the alarm has to stay in an inactive state for 5 seconds before the sensor status is recorded as normal. [. . . ] Add: Lets you add the IP address of a RemotEye II to the UPS List manually. Modify: Lets you modify the parameters of the RemotEye II selected in the UPS List. Upgrade: Sends the program loaded with the Open button to the selected RemotEye II of the UPS List. Note: You can simultaneously upgrade up to 6 RemotEye II on the network using the Tupgrade. exe program 128 Upgrading RemotEye II Firmware from Windows via Network Figure 27: Tugrade, RemotEye II Upgrade Utility via Network The RemotEye II firmware may be upgraded from a Windows platform by performing the following procedure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA REMOTEYE II




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA REMOTEYE II will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.