User manual TOSHIBA RBC-AMT31E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RBC-AMT31E. We hope that this TOSHIBA RBC-AMT31E user guide will be useful to you.


TOSHIBA RBC-AMT31E : Download the complete user guide (409 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RBC-AMT31E (990 ko)
   TOSHIBA RBC-AMT31E INSTALLATION MANUAL (73 ko)
   TOSHIBA RBC-AMT31E APPLICATION CONTROL MANUAL (6268 ko)
   TOSHIBA RBC-AMT31E INSTALLATION MANUAL (63 ko)
   TOSHIBA RBC-AMT31E APPLICATION CONTROL MANUAL (5070 ko)

Manual abstract: user guide TOSHIBA RBC-AMT31E

Detailed instructions for use are in the User's Guide.

[. . . ] OWNERS MANUAL MANUEL DU PROPRIETAIRE BETRIEBSANLEITUNG MANUALE DEL PROPRIETARIO MANUAL DEL PROPIETARIO MANUAL DO UTILIZADOR GEBRUIKSAANWIJZING WIRED STANDARD REMOTE CONTROLLER RBC-AMT31E Object Indoor Unit Super Modular Multi System/ Super Heat Recovery System <4-way Air Discharge Cassette Type> MMU-AP0091H, AP0121H, AP0151H, AP0181H, AP0241H, MMU-AP0271H, AP0301H, AP0361H, AP0481H, AP0561H <2-way Air Discharge Cassette Type> MMU-AP0071WH, AP0091WH, AP0121WH, AP0151WH, AP0181WH, AP0241WH, AP0271WH, MMU-AP0301WH MMU-AP0481WH (CHINA market only) <1-way Air Discharge Cassette Type> MMU-AP0071YH, AP0091YH, AP0121YH, AP0151SH, AP0181SH, AP0241SH <Concealed Duct Standard Type> MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH, AP0271BH, MMD-AP0301BH, AP0361BH, AP0481BH, AP0561BH <Concealed Duct High Static Pressure Type> MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0721H, AP0961H <Under Ceiling Type> MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H <High Wall Type> MMK-AP0071H, AP0072H, AP0091H, AP0092H, AP0121H, AP0122H, AP0151H, AP0181H, AP0241H <Floor Standing Cabinet Type> MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H <Floor Standing Concealed Type> MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH <Floor Standing Type> MMF-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0561H For commercial use Pour usage commercial Nur fr gewerbliche Nutzung Per uso commerciale Para uso comercial Para uso comercial Voor commercieel gebruik Digital Inverter Air Conditioner <4-way Air Discharge Cassette Type> RAV-SM560UT-E, SM800UT-E, SM1100UT-E, SM1400UT-E RAV-SP1100UT-E (Super Digital Inverter) <Under Ceiling Type> RAV-SM561CT-E, SM801CT-E, SM1101CT-E, SM1401CT-E <Concealed Duct High Static Pressure Type> RAV-SM561BT-E, SM801BT-E, SM1101BT-E, SM1401BT-E CODE No. SET DATA SETTING TEST UNIT No. H R. C. No. TEMP. ON / OFF ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refrigerant R22 in order to prevent destruction of the ozone layer. CAUTION Before using the remote controller (RBC-AMT31E), please read this Owner's Manual. For installation except operation of the remote controller, refer to the Installation Manual attached to the air conditioner unit. To use this remote controller safely and correctly, read this Instruction Manual thoroughly before use for full understanding. After you read this manual, be sure to keep it so that one who uses the remote controller can read this manual anytime. [. . . ] ON / OFF 10 2 5 3 1 2 3 4 FILTER RESET TEST 8 9 4 6 TIMER SET TIME SET CL FAN SWING/FIX UNIT MODE VENT Air volume select button Selects the desired air volume mode. The Concealed Duct High Static Pressure type models cannot be operated. Fan button FAN button is used when a fan which is sold on the market or etc. If is displayed on the remote controller when pushing the FAN button, a fan is not connected. Filter reset button Resets (Erases) "FILTER 7 Operation lamp Lamp is lit during the operation. Although it flashes when operating the protection device or abnormal time. button When the button is pushed, the operation starts, and it stops by pushing the button again. When the operation has stopped, the operation lamp and all the displays disappear. Set the desired set temperature by pushing or . ON / OFF 8 9 10 5 6 " display. Wind direction and Swing UNIT : If the multiple indoor units are operated by only one remote controller, select the units when the air direction is adjusted. This function is not provided to Concealed Duct Standard Type, High Static Pressure Type, Floor standing Cabinet Type, Floor Standing Concealed Type, or Slim Duct Type. Remote controller sensor Usually the TEMP sensor of the indoor unit senses . The temperature on the surrounding of the remote controller can also be sensed. For details, contact the dealer from which you have purchased the air conditioner. In case that one remote controller controls the multiple indoor units, the setup operation is unavailable in group control. 3 CORRECT USAGE When you use the air conditioner for the first time or when you change the SET DATA value, follow the procedure below. From the next time, the operation displayed on the remote controller will start by pushing the ON / OFF button only. Preparation Turn on the main power switch and/or the leakage breaker. When the power supply is turned on, a partition line is displayed on the display part of the remote controller. * After the power supply is turned on, the remote controller does not accept an operation for approx. 1 minute, but it is not a failure. REQUIREMENT While using the air conditioner, operate it only with button without turning off the main power switch and the leak breaker. Turn on the leak breaker 12 hours or more before start of operation after the air conditioner has stopped for a long time. TEMP. ON / OFF ON / OFF 4 TIMER SET TIME FILTER RESET TEST SET CL FAN SWING/FIX UNIT MODE VENT 3 1 2 1 2 Push button. One push of the button, and the display changes in the order shown on the right. "DRY mode" function is not provided to Concealed Duct High Static Pressure Type. MODE ON / OFF AUTO HEAT DRY (Dehumidity) COOL FAN AUTO HIGH MED. LOW 3 Select air volume with FAN button. One push of the button, and the display changes in the order shown on the right. When air volume is "AUTO In DRY mode, "AUTO ", air volume differs according to the room temperature. [. . . ] Every pushing UNIT button, the display exchanges as shown in the figure. UNIT 1, 2 No display Unit No. 1-2 1-way Air Discharge Cassette Type Adjustment of air direction upward/downward [In Cooling operation] In cooling operation, use the air outlet flap with horizontal set point so that the cold air diffuses in whole room. [In Heating operation (For Heat-pump model only)] In heating operation, use the air outlet flap with downward set point so that the hot air blows at the foot. Adjustment of air direction rightward/leftward To change the discharge direction to right or left side, set the vertical grille inside of the air outlet flap to the desired direction. Setup of air direction and swinging Refer to description of "2-way Air Discharge Cassette Type". 8 Right/Left air direction adjustment To change the air outlet direction to right or left side, set the vertical flap inside of the horizontal flap to the desired direction. INFORMATION If cooling operation is performed with downward discharge, dew may fall on surface of the cabinet or the horizontal flap resulted in dripping. If heating operation is performed with horizontal discharge, unevenness of temperature may increase in the room. High Wall Type Adjustment of air direction upward/downward [In Cooling operation] In cooling operation, use the horizontal flap with horizontal set point so that the cold air diffuses in whole room. [In Heating operation (For Heat-pump model only)] In heating operation, use the horizontal flap with downward set point so that the hot air blows at the foot. REQUIREMENT If cooling operation is performed with downward air outlet, dew may fall on surface of the cabinet or the horizontal flap resulted in dripping. If heating operation is performed with horizontal air outlet, unevenness of temperature may increase in the room. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RBC-AMT31E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RBC-AMT31E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.