User manual TOSHIBA RBC-AMS41E INSTALLATION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RBC-AMS41E. We hope that this TOSHIBA RBC-AMS41E user guide will be useful to you.


TOSHIBA RBC-AMS41E INSTALLATION MANUAL: Download the complete user guide (217 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RBC-AMS41E (3066 ko)

Manual abstract: user guide TOSHIBA RBC-AMS41EINSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Use Conditions · In COOL mode, if temperature of the fresh air is under the setup temp. When temperature of the fresh air is under 19°C, FAN status is also made regardless of the setup temperature. When temperature of the fresh air is over 15°C, FAN status is also made regardless of the setup temperature. · Operable mode and discharge temp setup range Operation mode COOL HEAT At shipment from factory 18°C 25°C Setup range 16 to 27°C 16 to 27°C · Special mentions 1. The fan operation of the Fresh Air Intake unit stops during defrosting. [. . . ] In cooling operation, if the temperature is below 5°C, the operation stops automatically. Specifications Fresh Air Intake Indoor Unit Type 50Hz Model name Cooling/Heating capacity (Note 1) Electical Power supply characteristics Running current Power consumption Starting current Outer dimension Total weight Heat exchanger Main unit Height Width Depth Main unit MMD-AP0481HFE MMD-AP0721HFE RBC-AMS41E (kW) 14. 0/8. 9 22. 4/13. 9 28. 0/17. 4 1 phase 50Hz 230V (220-240V) (A) 1. 43 2. 52 2. 73 (kW) (A) (mm) (mm) (mm) (kg) 892 1, 262 93 Finned tube Non-flammable insulation Centrifugal fan 1, 680 160 x 2 165 140-165-180 1, 176 Option or field supply Wired remote controller 22. 2 12. 7 R1 46/45/44 66/65/64 5 - 43 -5 - 43 144 0. 28 3. 50 0. 45 7. 00 492 1, 392 0. 52 7. 00 Soundproof / Heat-insulating material Fan Fan unit Standard air flow (m3/h) Motor (W) External static pressure (factory setting) External static pressure Air flow limit (m3/h) Lower limit/Upper limit Air filter Controller Connecting pipe Gas pipe (mm) Liquid pipe (mm) Drain pipe Sound pressure level (Note 2) (dB(A)) (High/Med. /Low) Sound power level (High/Med. /Low) (dB(A)) Operation range Cooling (Note 3) (°C) Heating (Note 4) (°C) 1, 080 160 210 170-210-230 756 2, 100 190 160-190-205 1, 470 15. 9 9. 5 45/43/41 65/63/61 * The setting temperature is 16 - 27°C(standard FCU. . . 18 - 29°C). * An option humidifier is not available with Fresh Air Intake Indoor unit. * Height difference between Fresh Air Intake Indoor units must be within 0. 5m. Height difference between Fresh Air Intake Indoor unit and standard FCU must be within 30m. Cooling : Outdoor air temperature 33°C DB/28°C WB setting temperature 18°C Heating : Outdoor air temperature 0°C DB/-2. 9°C WB setting temperature 18°C Piping : Length 7. 5m / Height 0m Note 2: The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values meausured in the actual operating environment become large than the indicated values due to the effects of external sound. Note 3: * When supply air temperature is "setting temperature + 3°C" or less, Fresh Air Intake unit operates as FAN mode. * When supply air temperature is 19°C or less, Fresh Air Intake Indoor unit operates as FAN mode. Note 4: * When supply air temperature is "setting temperature - 3°C" or over, Fresh Air Intake unit operates as FAN mode. Specifications Fresh Air Intake Indoor Unit Type Model name Cooling/Heating capacity (Note 1) Electical Power supply characteristics Running current Power consumption Starting current Height Main unit Width Depth 60Hz Outer dimension dimension Total weight Main unit Heat exchanger Soundproof / Heat-insulating material Fan unit Fan Standard air flow Motor External static pressure (factory setting) External static pressure Air flow limit (m3/h) Lower limit/Upper limit Air filter Controller Connecting pipe MMD-AP0481HFE MMD-AP0721HFE RBC-AMS41E (kW) 14. 0/8. 9 22. 4/13. 9 28. 0/17. 4 1 phase 60Hz 220V (A) 1. 66 2. 75 3. 12 (kW) 0. 34 0. 55 0. 65 (A) 3. 40 6. 80 6. 80 (mm) 492 (mm) 892 1, 392 (mm) 1, 262 93 144 (kg) Finned tube Non-flammable insulation Centrifugal fan 3 1, 080 1, 680 2, 100 (m /h) 160 160 x 2 (W) 215 115-215-260 1, 188 210 150-210-235 1, 848 Option or field supply Wired remote controller 22. 2 12. 7 R1 46/45/44 66/65/64 5 - 43 -5 - 43 180 80-180-220 2, 310 Gas pipe Liquid pipe Drain pipe Sound pressure level (Note 2) (High/Med. /Low) Sound power level (High/Med. /Low) Operation range Cooling (Note 3) Heating (Note 4) (mm) (mm) (dB(A)) (dB(A)) (°C) (°C) 15. 9 9. 5 45/43/41 65/63/61 * The setting temperature is 16 - 27°C(standard FCU. . . 18 - 29°C). Set the air inlet duct at descending inclination so that water can be drained even if rainwater enters in. The balloon entrance connection flange and the inhalation mouth connection flange are installed in the main body of the product. Please obtain Filter chamber directly in the main body of the product when you install Filter chamber and obtain installation Air intake port connecting flange for C side of A. Connect the ducts directly so that the ducts do not weight on the main unit. Moreover, please do not damage, and do not knock down air supply temperature sensor when you connect the air supply duct. Especially, when it is inhaled to heat it, the be dewy on the surface of the outside of the duct because cold air enters. When installing the drain pump and filter chamber sold separately, refer to attachment installation manual. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 8 3. Dimensions Fresh Air Intake Indoor Unit Type (MMD-AP***HFE) Discharge port connecting flange MMD-AP0481HFE 775 12 25 MMD-AP0721HFE, AP0961HFE 1130 12 65 215 215 215 65 65 250 250 250 250 65 25 394 370 394 344 370 725 25 25 25 1080 344 25 12 Suction port connecting flange MMD-AP0481HFE 630 12 25 12 8- 8 25 10- 8 MMD-AP0721HFE, AP0961HFE 1130 12 25 65 250 250 65 65 250 250 250 250 65 25 430 406 580 380 25 430 406 25 25 1080 380 25 25 12 6- 8 NOTE 1) The left figure shows MMD-AP0721HFE / AP0961HFE. For MMD-AP0481HFE, one fan motor and one fan are provided. 9 12 10- 8 25 4. Center of gravity Fresh Air Intake Indoor Unit Type Model name MMDAP0481HFE AP0721HFE AP0961HFE X (mm) 670 670 Y (mm) 480 770 Z (mm) 220 220 Weight (kg) 93 144 Z Y X Electric parts box 10 5. sensor 1. TC1, TC2, TCJ Temp sensor RY005~007 Fan Motor Control Relay RY002 Drain Control Relay Terminal block No. [. . . ] exchange the lead wire of arrow( ) position after check the terminal number as figure and lead wire's color of fan motor. (Option) DP RED RED FAN CN083(WHI) TA TCJ TC2 TC1 TF 6 RED 9 H L UL M 7 7 5 CN104 (YEL) CN102 (RED) CN101 (BLK) CN100 (BRW) CN030 (RED) FS CN103 (GRN) CN080 (GRN) 3 1 2 PNL 3 1 EXCT 2 1 FILTER 2 1 1 1 1 3 3 3 DP CN068 (BLU) LM CN033 (GRN) 13 123 12 12 12 12 12 12 13 123 12 12 7 7 BLK P301 CN073 (RED) RY007 Fan motor inside wiring diagram 8 43F1 spark killer 43F2 spark killer 8 BLU WHI WHI 1 3 RY002 RY001 CN304(GRY) CN070 (WHI) RY004 RY006 MMD-AP0721HFE RBC-AMS41E BLK 7 ORN 1 1 CN309 33 RED ACIN (YEL) RY005 Control P. C. Board for Indoor Unit MCC-1403 CN081 (BLK) WHI GRY RED 11 33 CN067(BLK) CN082 (BLU) CN075 (WHI) CN061(YEL) CN032 (WHI) CN060(WHI) Fuse T5. 0A 250V~ 49F 1 2 3 4 5 Motor over heating protection switch WHI Power supply circuit CN040 (BLU) CN041(BLU) CN050(WHI) CN074(WHI) 1 1 CN066(WHI) 22 CN044(BRW) 6 5 4 3 2 1 5 2 1 3 4 6 5 2 1 3 4 6 6 5 4 3 2 1 PMV 12 123456 12 FAN DRIVE OPTION T10 12345 123456 1 1 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) Sub P. C. Board MCC-1520 EMG OC BLU BLU BLK BLK 12 12 RC 123 13 3 3 123456 123456 6. Wiring diagrams Line Filter U1 U2 A B 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) TR1 RED AB Outdoor Unit Remote Controller Board WHI Remote Controller U1 U2 Fresh Air Intake Indoor Unit Type (8-10HP) 13 RED RED F1 1 RED Connector T10A, 250V~ RED RED T10A, 250V~ COLOR IDENTIFICATION RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN : ORANGE BRW : BROWN G&Y : GREEN&YELLOW 8 6 RED RED F2 3 WHI 6 43F2 ORN WHI 5 43F1 43F1 ORN 4 5 4 Indoor Unit Earth Screw WHI 3 R(L) YEL S(N) RC2 RC1 WHI RED GRY 4P 1234 1 2 3 4 (BLU) WHI RED GRY FAN2 WHI RED GRY A F1 BLU F2 ORN F3 BLK F4 Symbol Closed-end Connector Parts Name 1 2 3 4 4P 1 2 3 4 (WHI) WHI RED GRY FAN1 A F1 BLU F2 ORN F3 BLK F4 FM1 2 Fan Moter Power Supply 220-240V~50Hz 220V~60Hz RC1 2 WHI RED GRY 4P 1234 1 2 3 4 (WHI) WHI RED GRY BLU 1 2 ORN 3 BLK WHI RED GRY TR1 Running Capacitor Transformer 1 2 3 4 4P 1 2 3 4 (WHI) WHI RED GRY 1 BLU ORN 2 BLK 3 TA Intake air temp. sensor 1. FM2 G&Y G&Y FM1 TC1, TC2, TCJ Temp sensor RY005~007 Fan Motor Control Relay RY002 Drain Control Relay Terminal block No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RBC-AMS41E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RBC-AMS41E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.