User manual TOSHIBA RAV-SM562BT-E INSTALLATION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAV-SM562BT-E. We hope that this TOSHIBA RAV-SM562BT-E user guide will be useful to you.


TOSHIBA RAV-SM562BT-E INSTALLATION MANUAL: Download the complete user guide (703 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAV-SM562BT-E (3561 ko)
   TOSHIBA RAV-SM562BT-E SERVICE MANUAL (5671 ko)
   TOSHIBA RAV-SM562BT-E INSTALLATION MANUAL (1323 ko)
   TOSHIBA RAV-SM562BT-E PSD (7 ko)
   TOSHIBA RAV-SM562BT-E SERVICE MANUAL (5533 ko)
   TOSHIBA RAV-SM562BT-E INSTALLATION MANUAL (1323 ko)

Manual abstract: user guide TOSHIBA RAV-SM562BT-EINSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] AIR CONDITIONER (SPLIT TYPE) CLIMATISEUR (TYPE SPLIT) KLIMAGERT (SPLIT-TYP) CONDIZIONATORE D'ARIA (TIPO SPLIT) AIRE ACONDICIONADO (TIPO SPLIT) AR CONDICIONADO (TIPO SPLIT) AIRCONDITIONER (GESPLITST TYPE) ( SPLIT) INSTALLATION MANUAL MANUEL DINSTALLATION INSTALLATIONS-HANDBUCH MANUALE DINSTALLAZIONE MANUAL DE INSTALACIN MANUAL DE INSTALAO INSTALLATIEHANDLEIDING <Concealed Duct Type>/<Type conduits dissimuls> <Lftungskanalmontage in der Zwischendecke>/<Tipo a condotto nascosto> <Modelo con conductos ocultos>/<Tipo conduta embutida> <Type met weggewerkte kanalen>/< > Heat Pump Model/Modle thermopompe Gerte mit Heizung/Modello con pompa di riscaldamento Modelo con bomba de calor/Modelo de bomba trmica Model met warmtepomp/ Indoor Unit/Unit intrieure Raumeinheit/Unit interna Unidad interior/Unidade interior Binnenunit/ m Outdoor Unit/Unit extrieure Auengert/Unit esterna Unidad exterior/Unidade exterior Buitenunit/ m RAV-SM562BT-E RAV-SM802BT-E RAV-SM1102BT-E RAV-SM1402BT-E RAV-SM562AT-E RAV-SM802AT-E RAV-SM1102AT-E RAV-SM1402AT-E SP562AT-E SP802AT-E SP1102AT-E SP1402AT-E Please read this Installation Manual carefully before installing the Air Conditioner. For installation of the outdoor unit, follow the Installation Manual attached to the outdoor unit. Veuillez lire attentivement ce Manuel d'installation avant d'installer le climatiseur. Ce manuel dcrit la procdure d'installation de l'unit intrieure. [. . . ] Push the vinyl pipe in the drain socket completely up to the end of the socket. Do not apply strength to the connecting part until the adhesive agent has dried and hardened. Support the piping with hanging bracket so that the force is not applied to connection sections of pipe and pipe is not waved. NO GOOD Trap As shown in the figure, set the collective piping such as the ceiling duct so that waste water does not back up from the main pipe. NOTES : Do not make slack or trap at halfway across piping. Set pipes so that the end of drain pipe is not dipped in water, and also keep space 50mm or more to the ground. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe. 50 mm or more Do not put the drain hose end into water or drainage. OK NO GOOD Fit insulator so that there is no clearance. Thermal-insulating process After checking water drain, be sure to apply the thermal-insulating for connecting portion of the pipes. Apply taping so that there is no clearance on the fitting part of thermal-insulator of the main unit with the insulator procured locally. Hard polyethylene vinyl pipe Thermal insulator (Procured locally) (Procured locally) Fix thermal insulator by taping Thermal insulator (Main unit side) 14 5 DRAIN PIPING WORK Drain-up If down-slope cannot be set on a drain pipe, drain-up is possible. Set the height of drain pipe 550mm or less from the bottom face of the indoor unit. Pull out the drain pipe from connecting port of the drain pipe of the indoor unit by 100mm or shorter, and stand up it vertically. After standing up it vertically, arrange immediately so that it is set with down-slope. Standing-up: 550mm or less 100mm or shorter Indoor unit Connection of the drain hose Insert the drain hose completely into the connecting port of the drain pan. Apply thermal insulation surely to the drain hose with socket thermal insulation seal. VP 30 Less than 20m As long as possible (Approx. 100mm) VP 30 VP 30 Extended ventilating pipe VP 30 or more Downward grading 1/100 or more Check of water drain After drain pipe work, check that water is drained and there is no water leak from pipe connection portion. In this time, also check there is no trouble of motor sound of the drain pump. Be sure also to perform this check when installing the unit in heating time. After electric piping work Before installing a panel, infuse water as shown in the following figure. By operating the unit in COOL mode, check that water is drained from the drain pipe and then check there is no water leak from the drain pipe. Before electric piping work Pull out the float switch connector (3P: Red) from connector (CN34: Red) on P. C. (In this time, be sure to check the power has been turned off. ) Connect 220240V single-phase to L and N of the power supply terminal block. (Never apply 220240V to A , B , U1 , and U2 of the terminal block, otherwise it causes a trouble of P. C. (Water amount: 1500cc to 2000cc) The drain pump automatically operates by power-on. Check that water is drained from the drain pipe and then check there is no water leak from the drain pipe. After checking water drain and water leak, turn off the power, connect the float switch connector to the original position (CN34) of P. C. board, and then return the electric parts box to the original position. Insert the end of hose up to the near of suction port of drain pump. Service plate 220240V ~ single-phase L N White Black Black Red Pull out CN34 connector from P. C. board. 15 6 REFRIGERANT PIPING AND EVACUATING Flaring dia meter size : A (Unit : mm) A Outer diam. [. . . ] is displayed as [ ALL ] and fans and flaps of all the indoor units in the group control operate. TEST button to When the ITEM CODE is other than [01], push erase the display and repeat procedure from the first step. (After pushing TEST button, operation of the remote controller is not accepted for approx. 1 minute. ) UNIT VENT 1 CODE No. SET DATA SETTING TEST UNIT No. R. C. No. ( Display changes according to the model No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-SM562BT-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-SM562BT-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.