User manual TOSHIBA RAV-SM1403AT-E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAV-SM1403AT-E. We hope that this TOSHIBA RAV-SM1403AT-E user guide will be useful to you.


TOSHIBA RAV-SM1403AT-E SERVICE MANUAL: Download the complete user guide (5956 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAV-SM1403AT-E DATA BOOK (1949 ko)
   TOSHIBA RAV-SM1403AT-E INSTALLATION MANUAL (2155 ko)

Manual abstract: user guide TOSHIBA RAV-SM1403AT-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] 2007 SERVICE MANUAL/INTEGRATION AIR-CONDITIONER SPLIT TYPE INDOOR UNIT <DIGITAL INVERTER> RAV-SM563UT-E RAV-SM562BT-E RAV-SM803UT-E RAV-SM802BT-E RAV-SM1103UT-E RAV-SM1102BT-E RAV-SM1403UT-E RAV-SM1402BT-E <SUPER DIGITAL INVERTER> RAV-SP1102UT-E RAV-SM562CT-E RAV-SM802CT-E RAV-SM1102CT-E RAV-SM1402CT-E OUTDOOR UNIT <DIGITAL INVERTER> RAV-SM563AT-E RAV-SM803AT-E RAV-SM1103AT-E RAV-SM1403AT-E <SUPER DIGITAL INVERTER> RAV-SP562AT-E RAV-SP802AT-E RAV-SP1102AT-E RAV-SP1402AT-E R410A PRINTED IN JAPAN, Mar. , 2007 ToMo ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refrigerant R22 in order to prevent destruction of the ozone layer. WARNING Cleaning of the air filter and other parts of the air filter involves dangerous work in high places, so be sure to have a service person do it. The cleaning diagram for the air filter is there for the service person, and not for the customer. NOTE A direct current motor is adopted for indoor fan motor in the Concealed Duct Standard Type air conditioner. Caused from its characteristics, a current limit works on the direct current motor. When replacing the highperformance filter or when opening the service board, be sure to stop the fan. [. . . ] . C. Defective fan motor NOTE : However, GND circuit error inside of the motor is rarely detected even if the above check is carried out. When the circuit does not become normal even if P board has been replaced, replace outdoor fan motor. board CN300 CN301 RAV-SP562AT-E, SP802AT-E RAV-SM1103AT-E, SM1403AT-E CDB P board . C. YES NO Is voltage applied to 4-way valve coil terminal in heating operation?YES NO Check 4-way valve Defect Replace ® Check and replace electron expansion valve. NO Is circuit cable normal?YES NO Are characteristics of TC sensor resistance value normal? Check and correct circuit. * Refer to Characteristics-2. . C. ® · In cooling operation, if high pressure is abnormally raised, [P19 error] / [08 error] may be displayed. In this case, remove cause of pressure up and then check again referring to the item [P04 error] / [21 error]. [F02 error] Is connection of TC sensor connector (Indoor P board CN101) normal?YES NO Correct connection of connector. NO Replace TC sensor. * Refer to Characteristics-2. Check indoor P board . C. 2007 [F01 error] Is connection of TCJ sensor connector (Indoor P. C. YES NO Correct connection of connector. NO Replace TCJ sensor. * Refer to Characteristics-2. Check indoor P. C. YES Are not "P26" and "14" errors output when an operation is performed by removing 3P connector of compressor?Check and correct reactor connection. Improve the power supply line. Replace IPDU. YES NO Check and correct circuit cabling such as cabling to compressor. NO Is compressor normal?(Is resistance between windings 0. 6 to 1. 2W?) NO YES Is not winding opened?NO Compressor error ® Replace YES Compressor error ® Replace Compressor error ® Replace Check IPDU P. C. Defect ® Replace * For RAV-SM563AT-E, SM803AT-E, replace control P. C. board. [H03 error] Are cablings of power and current sensor normal?Defect ® Replace * For RAV-SM563AT-E, SM803AT-E, replace control P. C. 2007 [F06 error] Are connections of TE/TS sensor connectors of CDB CN604/CN605 normal?YES NO Correct connection of connector. * (For RAV-SM563AT-E, SM803AT-E, CN600 TE sensor and CN603 TS sensor) NO Replace TE and TS sensors. Check CDB. Defect Replace ® * Refer to Characteristics-3. [F04 error] Is connection of TD sensor connector of CDB CN600 normal? [. . . ] After then, incorporate front cabinet, upper cabinet, wiring cover, and valve cover as before. Return a set of the refrigeration cycle assembly into the outdoor unit base plate, and assemble sound insulation board, partition plate assembly, fan motor assembly, and side cabinet (R/L) as original. 3-1 Thermostat fixing plate Side cabinet (R) Using screws (Self-tapping screw type-B Ø4 × 8mm, stainless), fix the thermostat fixing plate to the side cabinet (R). 3-2 Do not make cord heater loose. Perform cable process for collected cord heater and fan motor lead cables. After incorporating the inverter assembly as before, furthermore perform cable process for cord heater and power cord. For the cord heater, perform cable process so that there is no looseness or sag at the fan side. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-SM1403AT-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-SM1403AT-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.