User manual TOSHIBA RAV-SM1402UT-E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAV-SM1402UT-E. We hope that this TOSHIBA RAV-SM1402UT-E user guide will be useful to you.


TOSHIBA RAV-SM1402UT-E : Download the complete user guide (435 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAV-SM1402UT-E SERVICE MANUAL (5671 ko)
   TOSHIBA RAV-SM1402UT-E PSD (7 ko)
   TOSHIBA RAV-SM1402UT-E SERVICE MANUAL (5533 ko)
   TOSHIBA RAV-SM1402UT-E INSTALLATION MANUAL (509 ko)

Manual abstract: user guide TOSHIBA RAV-SM1402UT-E

Detailed instructions for use are in the User's Guide.

[. . . ] AIR CONDITIONER (SPLIT TYPE) CLIMATISEUR (TYPE SPLIT) KLIMAGERT (SPLIT-TYP) CONDIZIONATORE D'ARIA (TIPO SPLIT) AIRE ACONDICIONADO (TIPO SPLIT) AR CONDICIONADO (TIPO SPLIT) AIRCONDITIONER (GESPLITST TYPE) ( ) OWNERS MANUAL MANUEL DU PROPRIETAIRE BETRIEBSANLEITUNG MANUALE DEL PROPRIETARIO MANUAL DEL PROPIETARIO MANUAL DO UTILIZADOR GEBRUIKSAANWIJZING <4-Way Air Discharge Cassette Type>/<Type cassette 4 voies de soufflage> <4-Wege-Belftungskassette>/<Tipo a cassetta con scarico d'aria a 4 vie> <Modelo de casete de distribucin de aire de 4 vas>/<Descarga de ar tipo cassete de 4 vias> <Model voor inbouw in plafond met 4 uitblaasopeningen>/< 4- > Heat Pump Model/Modle thermopompe Gerte mit Heizung/Modello con pompa di riscaldamento Modelo con bomba de calor/Modelo de bomba trmica Model met warmtepomp/ Indoor Unit/Unit intrieure Outdoor Unit/Unit extrieure Raumeinheit/Unit interna Auengert/Unit esterna Unidad interior/Unidade interior Unidad exterior/Unidade exterior Binnenunit/ Buitenunit/ RAV-SM562UT-E RAV-SM802UT-E RAV-SM1102UT-E RAV-SM1402UT-E RAV-SP1102UT-E RAV-SM562AT-E RAV-SM802AT-E RAV-SM1102AT-E RAV-SM1402AT-E SP562AT-E SP802AT-E SP1102AT-E SP1402AT-E Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this owner's manual carefully before using your Air Conditioner. Be sure to obtain the "Owner's manual" and "Installation manual" from constructor (or dealer). Request to constructor or dealer Please clearly explain the contents of the Owner's manual and hand over it. [. . . ] Do not use this air conditioner for special purpose such as preserving food, precision instruments, art objects, breeding animals, growing potted plants, etc. Avoid exposing potted plants and animals to the wind of the air conditioner, since it badly affects the health and growth of them. When the air conditioner is operated with a combustion appliance in the same place, be careful of ventilation to let fresh air enter the room. Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner, otherwise it may cause imperfect combustion. When the air conditioner is used in a closed room, be careful of sufficient ventilation of the room. Do not touch any switches with wet finger, otherwise you may get an electric shock. If the air conditioner won't be used for a considerably long time, turn off the main switch or the circuit breaker, for safety. If the base is left damaged or deteriorated, the unit may topple over and inflict an injury to a person as the worst case. If you do so, it may not only topple over the unit but also injure yourself. To make the air conditioner operate in its original performance, operate it within the range of the operating temperature specified in the instructions. Do not spill juice, water or any kind of liquid. 2 ENGLISH PARTS NAME Indoor unit Button Button to open/close the suction port Earth screw Provided in the electric parts box Air filter Removes dust or trash. (Provided on the suction port. ) Discharge flap of discharge port Change the direction of the air to be discharged according to cool/heat mode. Suction air port The air in the room is sucked in from this port. Projection of air filter Outdoor unit Remote controller Air inlet (Side and rear) CODE No. SET DATA SETTING TEST UNIT No. H R. C. No. TEMP. ON / OFF TIMER SET TIME FILTER RESET TEST SET CL FAN SWING/FIX UNIT MODE VENT Air outlet Pipes and electric wires The image of outdoor unit in the figure is in case Model RAV-SM802AT-E. 3 PARTS NAME OF REMOTE CONTROLLER Display section In the display example, all indicators are displayed for the explanation. When turning on the leak breaker at the first time, [SET DATA] flashes on the display part of the remote controller. While this display is flashing, the model is being automatically confirmed. Accordingly, wait for a while after [SET DATA] display has disappeared, and then use the remote controller. CODE No. SET DATA SETTING TEST UNIT No. H R. C. No. Display section ON / OFF TEMP. TIMER SET TIME FILTER RESET TEST SET CL FAN SWING/FIX UNIT MODE VENT Operation section 78 2 3 4 5 6 1 14 1 2 3 4 5 SET DATA display Displayed during setup of the timer. Operation mode select display The selected operation mode is displayed. CHECK display Displayed while the protective device works or a trouble occurs. (When a trouble occurs, the check code is displayed. ) Timer SETIN setup display When pushing the Timer SETIN button, the display of the timer is selected in order of [OFF] [OFF] repeat OFF timer [ON] No display. Filter display If "FILTER " is displayed, clean the air filter. 9 CODE No. SET DATA SETTING TEST UNIT No. 10 11 13 9 10 11 12 H R. C. No. 12 SWING display Displayed during up/down movement of the flap. Remote controller sensor display Displayed while the sensor of the remote controller is used. PRE-HEAT display Displayed when the heating operation starts or defrost operation is carried out. While this indication is displayed, the indoor fan stops or the mode enters in LOW. [. . . ] Do not install the air conditioner in a salty place such as seaside area. Do not install the air conditioner in a place where a great deal of machine oil is used. Do not install the air conditioner in a place where it is usually exposed to strong wind such as in seaside area or on the roof or upper floor of a building. Do not install the air conditioner in a place where sulfureous gas generated such as in a spa. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-SM1402UT-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-SM1402UT-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.