User manual TOSHIBA RAV-SM1402CT-E INSTALLATION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAV-SM1402CT-E. We hope that this TOSHIBA RAV-SM1402CT-E user guide will be useful to you.


TOSHIBA RAV-SM1402CT-E INSTALLATION MANUAL: Download the complete user guide (700 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAV-SM1402CT-E (3670 ko)
   TOSHIBA RAV-SM1402CT-E PSD (7 ko)
   TOSHIBA RAV-SM1402CT-E SERVICE MANUAL (5533 ko)

Manual abstract: user guide TOSHIBA RAV-SM1402CT-EINSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] AIR CONDITIONER (SPLIT TYPE) CLIMATISEUR (TYPE SPLIT) KLIMAGERT (SPLIT-TYP) CONDIZIONATORE D'ARIA (TIPO SPLIT) AIRE ACONDICIONADO (TIPO SPLIT) AR CONDICIONADO (TIPO SPLIT) AIRCONDITIONER (GESPLITST TYPE) ( SPLIT) INSTALLATION MANUAL MANUEL DINSTALLATION INSTALLATIONS-HANDBUCH MANUALE DINSTALLAZIONE MANUAL DE INSTALACIN MANUAL DE INSTALAO INSTALLATIEHANDLEIDING <Under Ceiling Type> / <Type sous le plafond> <Zwischendeckentyp> / <Tipo sotto il soffitto> <Modelo de techo> / <Tipo Sob o Tecto> <Type voor montage boven verlaagd plafond> / < > Heat Pump Model/Modle thermopompe Gerte mit Heizung/Modello con pompa di riscaldamento Modelo con bomba de calor/Modelo de bomba trmica Model met warmtepomp/ Indoor Unit/Unit intrieure Raumeinheit/Unit interna Unidad interior/Unidade interior Binnenunit/ m Outdoor Unit/Unit extrieure Auengert/Unit esterna Unidad exterior/Unidade exterior Buitenunit/ m RAV-SM562CT-E RAV-SM802CT-E RAV-SM1102CT-E RAV-SM1402CT-E RAV-SM562AT-E RAV-SM802AT-E RAV-SM1102AT-E RAV-SM1402AT-E SP562AT-E SP802AT-E SP1102AT-E SP1402AT-E Please read this Installation Manual carefully before installing the Air Conditioner. For installation of the outdoor unit, follow the Installation Manual attached to the outdoor unit. Veuillez lire attentivement ce Manuel d'installation avant d'installer le climatiseur. Ce manuel dcrit la procdure d'installation de l'unit intrieure. [. . . ] For details of installation, refer to the Installation Manual of the outdoor unit. Open the valve fully Open the valve of the outdoor unit fully. For details, refer to the Installation Manual attached to the outdoor unit. Air purge Using a vacuum pump, perform vacuuming from the charge port of valve of the outdoor unit. For details, follow to the Installation Manual attached to the outdoor unit. Never use the refrigerant sealed in the outdoor unit for air purge. Gas leak check Check with a leak detector or soap water whether gas leaks or not, from the pipe connecting section or cap of the valve. REQUIREMENT Use a leak detector manufactured exclusively for HFC refrigerant (R410A, R134a, etc. ). REQUIREMENT For the tools such as charge hose, etc. , use those manufactured exclusively for R410A. Thermal insulation process Apply thermal insulation for the pipes separately at liquid side and gas side. For the thermal insulation to the pipes at gas side, be sure to use the material with heat-resisting temperature 120C or higher. Using the attached thermal insulation material, apply the thermal insulation to the pipe connecting section of the indoor unit securely without gap. Refrigerant amount to be added For addition of the refrigerant, add refrigerant "R410A" referring to the attached Installation Manual of outdoor unit. Be sure to use a scale to charge the refrigerant of specified amount. REQUIREMENT Charging an excessive or too little amount of refrigerant causes a trouble of the compressor. A personnel who charged the refrigerant should write down the pipe length and the added refrigerant amount in the nameplate attached to the service panel of the outdoor unit. It is necessary to troubleshoot the compressor and refrigeration cycle malfunction. REQUIREMENT Apply the thermal insulation to the pipe connecting section of the indoor unit securely up to the root without exposure of the pipe. (The pipe exposed to the outside causes water leak. ) 12 5 ELECTRICAL WORK WARNING 1. Using the specified cables, ensure to connect the wires, and fix wires securely so that the external tension to the cables do not affect the connecting part of the terminals. Incomplete connection or fixation may cause a fire, etc. 2. (Grounding work) Do not connect the earth wire to gas pipe, city water pipe, lightning rod, or the earth wire of telephone. For electric work, strictly follow the Local Regulation in each country and the Installation Manual, and use an exclusive circuit. Capacity shortage of power circuit or incomplete installation may cause an electric shock or a fire. CAUTIONS This indoor unit has no power cord. If incorrect/incomplete wiring is carried out, it will cause an electrical fire or smoke. Be sure to install an earth leakage breaker that is not tripped by shock waves. If an earth leakage breaker is not installed, an electric shock may be caused. Do not damage or scratch the conductive core and inner insulator of power and inter-connecting cables when peeling them. Be sure to comply with local regulations on running the wire from outdoor unit to indoor unit (size of wire and wiring method etc. ) Use the power cord and Inter-connecting cable of specified thickness, type, and protective devices required. REQUIREMENT For power supply wiring, strictly conform to the Local Regulation in each country. For wiring of power supply of the outdoor units, follow the Installation Manual of each outdoor unit. Never connect 220240V power to the terminal blocks ( A , B , etc. ) for control wiring. (Otherwise, the system will fail. ) Perform the electric wiring so that it does not come to contact with the high-temperature part of the pipe. After connecting cables to the terminal blocks, provide a trap and fix cables with the cable clamp. [. . . ] of indoor unit. ) 2 3 In the group control, every pushing button, the indoor unit No. In this time, the position of the indoor unit can be confirmed because only fan and flap of the selected indoor unit operate. of the firstly displayed indoor unit becomes the header unit. ) After confirmation, push button to return the mode to the usual mode. TEST button, the display disappears and the status When pushing becomes the usual stop status. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-SM1402CT-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-SM1402CT-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.