User manual TOSHIBA RAV-SM1102AT-E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAV-SM1102AT-E. We hope that this TOSHIBA RAV-SM1102AT-E user guide will be useful to you.


TOSHIBA RAV-SM1102AT-E SERVICE MANUAL: Download the complete user guide (5533 Ko)

Manual abstract: user guide TOSHIBA RAV-SM1102AT-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] A05-018 SERVICE MANUAL/INTEGRATION SPLIT TYPE INDOOR UNIT <DIGITAL INVERTER> RAV-SM562UT-E RAV-SM562BT-E RAV-SM802UT-E RAV-SM802BT-E RAV-SM1102UT-E RAV-SM1102BT-E RAV-SM1402UT-E RAV-SM1402BT-E <SUPER DIGITAL INVERTER> RAV-SP1102UT-E RAV-SM562CT-E RAV-SM802CT-E RAV-SM1102CT-E RAV-SM1402CT-E · Service Manual for RAV-SMKRT and RAV-SMXT contact the Sales company or Dealer. OUTDOOR UNIT <DIGITAL INVERTER> RAV-SM562AT-E RAV-SM802AT-E <SUPER DIGITAL INVERTER> RAV-SP562AT-E RAV-SP802AT-E RAV-SM1102AT-E RAV-SP1102AT-E RAV-SM1402AT-E RAV-SP1402AT-E R410A PRINTED IN JAPAN, Jan. , 2006 ToMo ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refrigerant R22 in order to prevent destruction of the ozone layer. WARNING Cleaning of the air filter and other parts of the air filter involves dangerous work in high places, so be sure to have a service person do it. The cleaning diagram for the air filter is there for the service person, and not for the customer. NOTE A direct current motor is adopted for indoor fan motor in the Concealed Duct Standard Type air conditioner. Caused from its characteristics, a current limit works on the direct current motor. When replacing the highperformance filter or when opening the service board, be sure to stop the fan. [. . . ] board. [H03 error] Are cablings of power and current sensor normal?board. ­ 93 ­ [F06 error] Are connections of TE/TS sensor connectors of CDB CN604/CN605 normal?YES NO Correct connection of connector. * (For RAV-SM562AT-E, CN600 TE sensor and CN603 TS sensor) NO Replace TE and TS sensors. Check CDB. Defect Replace ® * Refer to Characteristics-3. [F04 error] Is connection of TD sensor connector of CDB CN600 normal?YES NO Correct connection of connector. * (For RAV-SM562AT-E, CN601 TD sensor) NO Replace TD sensor. Check control P. C. Defect Replace ® * Refer to Characteristics-4. [F08 error] Is connection of TO sensor connector of CDB CN601 normal?YES NO Correct connection of connector. * (For RAV-SM562AT-E, CN602 TO sensor) NO Replace TO sensor. Check CDB. Defect Replace ® * Refer to Characteristics-5. ­ 94 ­ [L29 error] Are connections of CDB CN800 and CDB IPDU CN06 connectors normal?NO NO Correct connection of connector. YES Are cabling/connector normal?YES NO Check cabling between IPDU and CDB and connector. IPDU P. C. board error Defect Replace ® YES Is there no abnormal overload?YES NO Improve and eliminate the cause. Correct mounting. IPDU P. C. board error Defect Replace ® [H02 error] NO Is power voltage normal?YES NO NO NO Improve power line. Check and correct circuit cabling such as cabling to compressor (phase missing) and connector. Compressor lock ® Replace ® ® Check TE and TS sensors. board. ­ 95 ­ [P03 error] Is protective control such as discharge temprelease control normal?YES NO Correct the cabling and connection of connector. Check parts. YES NO * Refer to Characteristics-4. Check and correct the charged refrigerant amount. Improve and delete the cause Replace TD sensor. Check CDB. YES NO Improve and delete the cause. Check and correct circuit cables. Check IPDU. board. ® ­ 96 ­ [P04 error] Is high-voltage protective operation by TE sensor normal?YES NO Correct connection of cabling connector. Check TE sensor. YES Are characteristics of TD, TO, TC sensor resistance values normal?NO ® Correct coming-off. Replace TD, TO, and TC sensors. * Refer to Characteristics-3 and 4. Check CDB. [. . . ] Fix the thermostat fixing plate to the side cabinet (R), built in the inverter assembly, and then connect various cables. After then, incorporate front cabinet, upper cabinet, wiring cover, and valve cover as before. Return a set of the refrigeration cycle assembly into the outdoor unit base plate, and assemble sound insulation board, partition plate assembly, fan motor assembly, and side cabinet (R/L) as original. 3-1 Thermostat fixing plate Side cabinet (R) Using screws (Self-tapping screw type-B Ø4 × 8mm, stainless), fix the thermostat fixing plate to the side cabinet (R). 3-2 Do not make cord heater loose. Perform cable process for collected cord heater and fan motor lead cables. After incorporating the inverter assembly as before, furthermore perform cable process for cord heater and power cord. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-SM1102AT-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-SM1102AT-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.