User manual TOSHIBA RAV-SM1101AT-E INSTALLATION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAV-SM1101AT-E. We hope that this TOSHIBA RAV-SM1101AT-E user guide will be useful to you.


TOSHIBA RAV-SM1101AT-E INSTALLATION MANUAL: Download the complete user guide (2826 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAV-SM1101AT-E SERVICE MANUAL (3688 ko)

Manual abstract: user guide TOSHIBA RAV-SM1101AT-EINSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] A05-002 OWNERS MANUAL/INSTALLATION MANUAL SPLIT TYPE <NEW DIGITAL INVERTER> OUTDOOR UNIT RAV-SM561AT-E, RAV-SM801AT-E, RAV-SM1101AT-E, RAV-SM1401AT-E R410A PRINTED IN JAPAN, Apr. , 2005 ToMo CONTENTS OUTDOOR INSTALLATION MANUAL RAV-SM561AT-E, RAV-SM801AT-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 RAV-SM1101AT-E, RAV-SM1401AT-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 INDOOR OWNERS MANUAL 4-Way Air Discharge Cassette Type RAV-SP1100UT-E, RAV-SM560UT-E, RAV-SM800UT-E, RAV-SM1100UT-E, RAV-SM1400UT-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Concealed Duct Type RAV-SM561BT-E, RAV-SM801BT-E, RAV-SM1101BT-E, RAV-SM1401BT-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (2) Stop the air conditioner and turn off the main power switch or the circuit breaker. Checks before operation (1) Check that the air filters are installed. (3) Turn on the main power switch or the circuit breaker for the main power supply to the air conditioner. WARNING Cleaning of the air filter and other parts of the air filter involves dangerous work in high places, so be sure to have a service person do it. Do not attempt it yourself. NOTE For Air conditioning system which is operated regularly, cleaning and maintenance of the indoor/outdoor units are strongly recommended. As a general rule, if an indoor unit is operated for about 8 hours daily, the indoor/outdoor units will need to be cleaned at least once every 3-MONTH. This cleaning and maintenance shall be carried out by a qualified person. Failure to clean the indoor/outdoor units regularly will result in poor performance, icing, water leaking and even compressor failure. ­ 69 ­ RAV-SM561CT-E, RAV-SM801CT-E, RAV-SM1101CT-E, RAV-SM1401CT-E AIR CONDITIONER OPERATIONS AND PERFORMANCE 3 minutes protection function 3-minutes protection function prevents the air conditioner from starting for initial 3 minutes after the main power switch/circuit breaker is turned on for re-starting the air conditioner. Power failure Power failure during operation will stop the unit completely. · To restart the operation, push the START/STOP button on the remote controller. · Lightning or a wireless car telephone operating nearby may cause the unit to malfunction. Turn off the main power switch or circuit breaker and then turn them on again. Push the START/STOP button on the remote controller to restart. Heating characteristics Preheating operation The air conditioner will not deliver warm air immediately after it is turned on. Warm air will start to flow out after approximately 5 minutes when the indoor heat exchanger warmed up. Warm air control (In heating operation) When the room temperature reaches the set temperature, the fan speed is automatically reduced to prevent to blow cold draft. At this time, the outdoor unit will stop. Defrosting operation If the outdoor unit is frosted during the heating operation, defrosting starts automatically (for approximately 2 to 10 minutes) to maintain the heating capacity. · The fans in both indoor and outdoor units will stop during the defrosting operation. · During the defrosting operation, the defrosted water will be drained from the bottom plate of the outdoor unit. Heating capacity In the heating operation, the heat is absorbed from the outside and brought into the room. When the outside temperature is too low, it is recommended to use another heating apparatus in combination with the air conditioner. Attention to snowfall and freeze on the outdoor unit · In snowy areas, the air inlet and air outlet of the outdoor unit are often covered with snow or frozen up. If snow or freeze on the outdoor unit is left as it is, it may cause machine failure or poor warming. · In cold areas, pay attention to the drain hose so that it perfectly drains water without water remaining inside for freeze prevention. If water freezes in the drain hose or inside the outdoor unit, it may cause machine failure or poor warming. Air conditioner operating conditions For proper performance, operate the air conditioner under the following temperature conditions: Cooling operation Outdoor temperature : ­5°C to 43°C (RAV-SM0AT-E) ­15 to 43°C (RAV-SPAT-E, RAV-SM1AT-E) : 21°C to 32°C (Dry valve temp. ), 15°C to 24°C (Wet valve temp. ) Room temperature CAUTION Heating operation Room relative humidity ­ less than 80 %. If the air conditioner operates in excess of this figure, the surface of the air conditioner may cause dewing. : ­15°C to 15°C (Wet valve temp. ) : 15°C to 28°C (Dry valve temp. ) Outdoor temperature Room temperature If air conditioner is used outside of the above conditions, safety protection may work. ­ 70 ­ RAV-SM561CT-E, RAV-SM801CT-E, RAV-SM1101CT-E, RAV-SM1401CT-E RE-INSTALLATION DANGER Ask the dealer or an installation professional to re-install the air conditioner to a new place or move it to another place and to observe the following items. If the air conditioner is inappropriate installed by yourself, it may cause electric shock or fire. Do not install the air conditioner in the following places · Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set. If the unit is installed in such place, noise transmitted from the air conditioner affects the operation of these appliances. [. . . ] · Set according to the basic operation procedure (1 2 3 4 5 6 ). · Select [Set data] in Procedure from "List of installable ceiling height" in this Manual. · For the set data in Procedure 4, select the setup data of static pressure outside of the machine to be set up from the table below. (Exchange by wired remote controller) Set data 0000 0001 Standard (At shipment) High static pressure 1 3. 5m or less 4. 0m or less When using wireless remote controller To exchange the static pressure, there is a method other than the abovementioned method by wired remote controller, which is to shift the short plug on the indoor microcomputer P. C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-SM1101AT-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-SM1101AT-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.