User manual TOSHIBA RAV-362CH-PE SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAV-362CH-PE. We hope that this TOSHIBA RAV-362CH-PE user guide will be useful to you.


TOSHIBA RAV-362CH-PE SERVICE MANUAL: Download the complete user guide (2429 Ko)

Manual abstract: user guide TOSHIBA RAV-362CH-PESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONSTRUCTION VIEWS (EXTERNAL VIEWS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SYSTEMATIC REFRIGERATING CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Rotate the fan slowly with hands, and check the pin voltage swings between 0 to 5V voltage. Defect Replace CN334 54 [P22 error]/[1A error] Are connections of CN301, CN303 and CN300 of P. C. YES Does the fan rotate without trouble when handling the fan with hands under condition of removing CN301, CN303 and CN300, CN302 from P. C. YES The status that the resistance values between leads below are 25 to 55 for 63W motor (ICF-140-63-2) is normal. Between 1 (Red lead) and 2 (White lead) Between 2 (White lead) and 3 (Black lead) Between 3 (Black lead) and 1 (Red lead) of motor winding of connector (CN301, CN303) YES The status that there is 5k to 20k resistance values between 1 (Yellow lead) and 4 (Pink lead) of motor position detection of connector (CN300, CN302) is normal. YES NO CN301, CN303 NO CN300, CN302 CN301, CN303: Motor coil winding CN300, CN302: Motor position detection NO Normal fan motor (CDB P. C. board) Defective fan motor NOTE : However, GND circuit error inside of the motor is rarely detected even if the above check is carried out. board has been replaced, replace outdoor fan motor. Single phase RAV-362CH-PE, RAV-SP800AT-E Objective P. C. board Fan motor winding Motor position detection Fan motor winding Motor position detection CDB P. C. board CN301 CN300 ---- ---- Single phase RAV-SP1100AT-E, RAV-SP1400AT-E CDB P. C. board CN301 CN300 CN303 CN302 55 [P19 error]/[08 error] Is operation of 4-way valve normal?YES NO Correct connection of connector. NO Replace TO sensor. Check CDB. Defect Replace * Refer to Characteristics-5. 59 [L29 error]/[1C error] Are connections of CDB CN800 and CDB IPDU CN06 connectors normal?NO NO Correct connection of connector. YES Are cabling/connector normal?YES NO Check cabling between IPDU and CDB and connector. IPDU P. C. YES NO Improve and eliminate the cause. Correct mounting. IPDU P. C. board error Defect Replace [H02 error]/[1d error] NO Is power voltage normal?YES NO NO NO Improve power line. Check and correct circuit cabling such as cabling to compressor (phase missing) and connector. Compressor lock Replace Check TE and TS sensors. Defect Replace 60 [P03 error]/[1E error] Is protective control such as discharge temprelease control normal?YES NO Correct the cabling and connection of connector. Check parts. YES NO * Refer to Characteristics-4. Check and correct the charged refrigerant amount. Improve and delete the cause Replace TD sensor. Check CDB. YES NO Improve and delete the cause. Check and correct circuit cables. Check IPDU. [. . . ] By doing so, the power consumption can be decreased because the breaker can be turned off if there is no possibility of freezing of the base in cooling operation, etc. When the cord heater power is connected to the inverter P board assembly or others without connected to the . C. exclusive breaker, the control P board of the inverter assembly may cause a failure. 1 1-2 Photo / Explanatory diagram Procedure Remove each cabinet, inverter assembly, motor base assembly, and partition board assembly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-362CH-PE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-362CH-PE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.