User manual TOSHIBA RAS-M07SKV-E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-M07SKV-E. We hope that this TOSHIBA RAS-M07SKV-E user guide will be useful to you.


TOSHIBA RAS-M07SKV-E SERVICE MANUAL: Download the complete user guide (4015 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAS-M07SKV-E DOCUMENTATION COMMERCIALE (2293 ko)

Manual abstract: user guide TOSHIBA RAS-M07SKV-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SVM-07034-2 SERVICE MANUAL SPLIT TYPE Indoor Unit <High Wall, Heat Pump Type> RAS-M07SKV-E RAS-M10SKV-E RAS-M13SKV-E RAS-M16SKV-E <High Wall, Cooling Type> RAS-M10SKCV-E RAS-M13SKCV-E RAS-M16SKCV-E R410A Revised May, 2009 CONTENTS 1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Comfort sleep mode will not operate in dry mode and fan only mode. 13. Short Timer In the normal condition, after switching one circuit breaker, 3-minute delay time for compressor and 1 hour for plasma air purifier are set for the maintenance of the unit. Purpose To start the unit immediately for the purpose of testing, trial. . . etc, short timer can be used. Short Timer Setting j k l Press [ ] button to turn the unit OFF. Set the operation mode or plasma air purifier on the remote control without sending the signal to the unit. Use the tip of the pencil to push the [CHK] button and hold, "00" will show on display, them press [SET] button to make "00" disappear. When short timer is activated, all setting on the remote operates immediately, besides, all indicatiors on front panel turns ON continuously for 3 seconds. m n - 38 - Item 14. One-Touch Comfort Operation flow and applicable data, etc. One touch comfort is the fully automated operation that is set according to the preferable condition in a region. Description Operation condition for model to Europe market When an indoor unit receives "One Touch Comfort Signal" from the remote controller, the indoor unit operates as following. 1) Air conditioner starts to operation when the signal is received, even if the air conditioner was OFF. 2) Operation mode is set according to room temperature, the same as AUTO mode. 5) Fan is controlled as followings. Fan Operation AUTO * AUTO/L L 0 12 25 Time after operation starts (min) *AUTO/L: Fan operates depends on the setting temperature and room temperature. During the One Touch Comfort mode if the indoor unit receives any signal with other operation mode, the unit will cancel the comfort mode and operates according to the signal received. 15. Hi-POWER Mode ([Hi-POWER] button on the remote controller is pressed) When [Hi-POWER] button is pressed while the indoor unit is in Auto, Cooling or Heating operation, HiPOWER mark is indicated on the display of the remote controller and the unit operates as follows. 1. Automatic operation · The indoor unit operates in according to the current operation. Cooling operation · The preset temperature drops 1ºC (The value of the preset temperature on the remote controller does not change. ) The indoor unit's fan speed level increase 1 tap 3. Heating operation · The preset temperature increases 2ºC (The value of the preset temperature on the remote controller does not change. ) The indoor unit's fan speed level increase 1 tap 4. FILTER Indicator When the elapsed time reaches 1000 hours after air purifier operation, the FILTER indicator lights. How to Turn Off FILTER Indicator Press [RESET] button on the indoor unit. NOTE : If [RESET] button is pushed while the FILTER indicator is not lit, the indoor unit will start the automatic operation. When you want a temporary operation while the FILTER lamp lights, press [RESET] button to turn off the FILTER lamp. Auto Restart Function This indoor unit is equipped with an automatic restarting function which allows the unit to restart operating with the set operating conditions in the event of a power supply being accidentally shut down. The operation will resume without warning three minutes after power is restored. How to Set the Auto Restart Function To set the auto restart function, proceed as follows: The power supply to the unit must be on ; the function will not set if the power is off. Press the [RESET] button located in the center of the front panel continuously for three seconds. The unit then restarts operating automatically in the event of power supply being accidentally shut down. · When the unit is standby (Not operating) Operation Press [RESET] button for more than three seconds. Motions The unit beeps three times and continues to operate. Hi POWER FILTER PAP TIMER OPERATION If the unit is not required to operate at this time, press [RESET] button once more or use the remote controller to turn it off. RESET · When the unit is in operation Operation Press [RESET] button for more than three seconds. [. . . ] · If keeping the power on is absolutely unavoidable while doing a job such as inspecting the circuitry, wear rubber gloves to avoid contact with the live parts. Proceed very carefully when conducting checks since directly touching the parts on the control circuit board may result in electric shocks. 12-1. Part name Front panel Procedures 1) Stop operation of the air conditioner and turn off its main power supply. 2) Open the air inlet grille, push the arm toward the outside, and remove the grille. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-M07SKV-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-M07SKV-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.