User manual TOSHIBA RAS-B13SKVP-E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-B13SKVP-E. We hope that this TOSHIBA RAS-B13SKVP-E user guide will be useful to you.


TOSHIBA RAS-B13SKVP-E SERVICE MANUAL: Download the complete user guide (14352 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAS-B13SKVP-E (3525 ko)
   TOSHIBA RAS-B13SKVP-E INSTALLATION MANUAL (1507 ko)
   TOSHIBA RAS-B13SKVP-E DOCUMENTATION COMMERCIALE (2293 ko)

Manual abstract: user guide TOSHIBA RAS-B13SKVP-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] A06-011 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE Indoor Unit <High Wall, Heat Pump Type> (Standard Type) Outdoor Unit <Heat Pump Type> RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-E (North Europe Type) RAS-10SAVP-E RAS-13SAVP-E RAS-16SAVP-E RAS-10SAVP-ND RAS-13SAVP-ND RAS-16SAVP-ND RAS-10SKVP-ND RAS-13SKVP-ND RAS-16SKVP-ND R410A PRINTED IN JAPAN, Fub, 2007 ToMo CONTENTS 1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (The value of the preset temperature on the remote controller does not change. ) 4. Release of Hi POWER mode · Push [Hi POWER] button on the remote controller again. ­ 54 ­ 10. Safety Cautions Hook 47 mm or more 1 Installation plate Hook 140 mm or more 74 mm or more Hook Wall For the rear left and left piping Insert the cushion between the indoor unit and wall, and tilt the indoor unit for better installation work. 6 Mounting screw Do not allow the drain hose to become slack. Cut the piping hole slightly sloped 5 Plasma pure filter Air filters 2 Wireless remote controller Z Shield pipe (for extension drain hose) Make sure the drain hose is sloped downward. 80 mm or more only when unobstructed to the front and both sides In principle, leave open The auxiliary piping can be connected at the left, rear left, rear right, right, bottom right or bottom left as shown below. Y 100 mm or more from wall (C) Right 50 mm or more from wall (D) Rear right 4 Remote controller holder Bottom left Bottom right Left Rear left 200 mm or more (B) 7 Remote controller holder mounting screw (A) As shown in the figure, position power cord and connecting cable downward, and lead out along piping connection port. 250 mm or more from wall When installing the outdoor unit, leave open in at least two of directions (A), (B), (C) and (D) shown in the figure below. Ensure sufficient space to allow drainage Power cord Extension drain hose (Option: RB-821SW) Insulate the refrigerant pipes separately, not together. Before installing the wireless remote controller · With the remote controller cover removed, correctly load the supplied batteries while observing their polarity. 2 Wireless remote controller Cover 3 Batteries 6 mm thick heat resisting polyethylene foam · Indoor units connectable with a multi-system outdoor unit (Other indoor units are unavailable. ) RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E · When using a multi-system outdoor unit, refer to the installation manual provided with the model concerned. ­ 55 ­ 10-2. Optional Installation Parts Part Code Parts name Refrigerant piping Indoor unit name Y Q'ty Liquid side (Outer diameter) 6. 35 mm 6. 35 mm Gas side (Outer diameter) 9. 52 mm 12. 7 mm . 1 ea. RAS-B10SKVP-E, B13SKVP-E RAS-10SKVP-ND, 13SKVP-ND RAS-B16SKVP-E, 16SKVP-ND Z Shield pipe (for extension drain hose) (polyethylene foam, 6 mm thick) 1 Attachment bolt arrangement of outdoor unit · Secure the outdoor unit with the attachment bolts and nuts if the unit is likely to be exposed to a strong wind. If it is necessary to drain the defrost water, attach drain nipple to the base plate of the outdoor unit before installing it. Elongated drain hole ( ) Suction side Diffuser Drain hole ( ) 10-2-2. Part name (Q'ty) Installation plate × 1 Remote controller holder × 1 Remote controller holder mounting screw Ø3. 1 × 16L × 2 Wireless remote controller × 1 Plasma pure filter × 1 Drain nipple* × 1 Battery × 2 Mounting screw Ø4 × 25L × 6 Water-proof rubber cap* × 2 <Others> Name Owner's manual Installation manual Important information and warning* B/W strips* (Energy efficiency labels) This model is not equipped with an extension drain hose. Parts marked with asterisk (*) are packaged with the outdoor unit. Option: For the extension drain hose, use the optionally available RB-821SW or a commercially available one. · Indoor units connectable with a multi-system outdoor unit (Other indoor units are unavailable. ) RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E · When using a multi-system outdoor unit, refer to the installation manual provided with the model concerned. ­ 56 ­ 10-2-3. Installation/Servicing Tools Changes in the product and components In the case of an air conditioner using R410A, in order to prevent any other refrigerant from being charged accidentally, the service port diameter of the outdoor unit control valve (3 way valve) has been changed. (1/2 UNF 20 threads per inch) · In order to increase the pressure resisting strength of the refrigerant piping flare processing diameter and size of opposite side of flare nuts has been changed. (for copper pipes with nominal dimensions 1/2 and 5/8) New tools for R410A New tools for R410A Applicable to R22 model Changes As pressure is high, it is impossible to measure by means of conventional gauge. In order to prevent any other refrigerant from being charged, each port diameter has been changed. In order to increase pressure resisting strength, hose materials and port size have been changed (to 1/2 UNF 20 threads per inch). As pressure is high and gasification speed is fast, it is difficult to read the indicated value by means of charging cylinder, as air bubbles occur. Incidentally, a common wrench is used for nominal diameters 1/4 and 3/8. By increasing the clamp bar's receiving hole, strength of spring in the tool has been improved. Gauge manifold × × ¡ Charge hose Electronic balance for refrigerant charging Torque wrench (nominal diam. 1/2, 5/8) × ¡ -- -- Flare tool (clutch type) Gauge for projection adjustment Used when flare is made by using conventional flare tool. It is necessary to use an adapter to prevent vacuum pump oil from flowing back to the charge hose. The charge hose connecting part has two ports-one for conventional refrigerant (7/16 UNF 20 threads per inch) and one for R410A. If the vacuum pump oil (mineral) mixes with R410A a sludge may occur and damage the equipment. Vacuum pump adapter ¡ Gas leakage detector × Exclusive for HFC refrigerant. · Incidentally, the "refrigerant cylinder" comes with the refrigerant designation (R410A) and protector coating in the U. · Also, the "charge port and packing for refrigerant cylinder" require 1/2 UNF 20 threads per inch corresponding to the charge hose's port size. ­ 57 ­ 10-3. Installation Location · A place which provides enough spaces around the indoor unit as shown in the diagram. [. . . ] 223 224 225 226 227 229 230 232 233 234 237 238 239 240 243 245 246 248 Part No. 43049674 43047673 43044821 43044822 43039324 43019904 43049770 43062256 43062247 43082293 43083071 43003311 43070188 43079268 43066016 43080528 43080563 4308N972 Description Spring (16SKVP-ND) Pipe Ass'y, Connecting, Liquid Evaporator Ass'y (10SKVP-ND, 13SKVP-ND) Evaporator Ass'y (16SKVP-ND) Guide, Drain Holder, Sensor Holder, Evaporator, Right Cover, Terminal Cover, Lead Plate, Installation Holder, Remote Controller Body Ass'y, Back Hose, Drain Cap, Drain Remote Controller, WH-H05JE Plasma Pure Filter Generator Ass'y, HV Owner's Manual ­ 110 ­ 402 411, 412, 413 403 406 404 405 410 401 The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing. 4306A132 43062263 43050425 43050426 4306S936 43051350 Description Terminal Block, 3P Cover, E-Parts Sensor, TC (Ø6), TCJ (Ø6) Sensor, TA P Board Ass'y, WRS-LED . C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-B13SKVP-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-B13SKVP-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.