User manual TOSHIBA RAS-4M27YAV-E DATA BOOK

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-4M27YAV-E. We hope that this TOSHIBA RAS-4M27YAV-E user guide will be useful to you.


TOSHIBA RAS-4M27YAV-E DATA BOOK: Download the complete user guide (51 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAS-4M27YAV-E (3000 ko)
   TOSHIBA RAS-4M27YAV-E INSTALLATION MANUAL (975 ko)
   TOSHIBA RAS-4M27YAV-E SERVICE MANUAL (13283 ko)

Manual abstract: user guide TOSHIBA RAS-4M27YAV-EDATA BOOK

Detailed instructions for use are in the User's Guide.

[. . . ] This air conditioner requires special installation for the refrigerant R410A. -2- FILE NO. SPECIFICATIONS MODEL ITEM Capacity 220V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB dB kg mm mm 49 51 49 R410A 0. 95 Capillary tube 12. 7 Flare connection 6. 35 Flare connection m m RAS-13UKHP-ES3, AS3 Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range C 15 ~ 43 Model Output W m /h 3 RAS-13UKHP-ES3, AS3 RAS-13UAH-ES3, AS3 Cooling 240V 3. 60 220V 4. 20 1 220 - 240 50 1. 10 98 4. 95 1. 12 97 4. 65 27 2. 0 41/35/31 51 1. 14 97 0. 15 5. 20 4. 95 1. 18 96 3. 60 Heating 240V 4. 26 RAS-13UKP-ES3, AS3 RAS-13UA-ES3, AS3 Cooling 220V 3. 75 240V 3. 75 1. 13 98 5. 10 28 1. 17 97 4. 90 Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Outdoor (220-240V) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference INDOOR UNIT 49 50 Refrigerant control 15*1 6 RAS-13UKP-ES3, AS3 275 790 208 10 Finned tube Cross flow fan mm mm mm kg Width Depth m3/h m /h 3 630 520 430 650 550 490 20 Honeycomb woven filter with PP frame RAS-13UAH-ES3, AS3 630 520 430 m3/h W RAS-13UA-ES3, AS3 550 780 270 mm mm mm kg 39 Width Depth 37 Finned tube Propeller fan 2120 2200 42 2120 2200 2030 30 2150 W PA150X2T-4FM1 1100 Fuse, Overload relay Automatic louver -10 ~ 24 15 ~ 43 -3- FILE NO. SVM-04001 MODEL ITEM Capacity 220V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB dB kg mm mm 47 3. 65 0. 82 98 2. 70 RAS-10UKHP-ES3, AS3 RAS-10UAH-ES3, AS3 Cooling 240V 2. 70 220V 2. 90 1 220 - 240 50 0. 84 97 3. 45 0. 78 97 0. 15 3. 50 18 1. 2 39/33/26 49 0. 70 Capillary tube 9. 52 Flare connection 6. 35 Flare connection 47 R410A 49 3. 40 0. 82 96 Heating 240V 2. 96 RAS-10UKP-ES3, AS3 RAS-4M27YAV-E, AS3 Cooling 220V 2. 70 240V 2. 70 0. 82 98 3. 80 0. 84 97 3. 60 Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Outdoor (220-240V) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference INDOOR UNIT Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range Model Output Width Depth Width Depth 46 0. 65 47 Refrigerant control m m RAS-10UKHP-ES3, AS3 mm mm mm kg 10*1 5 RAS-10UKP-ES3, AS3 275 790 208 10 Finned tube Cross flow fan m3/h m /h 3 570 460 340 610 520 400 20 Honeycomb woven filter with PP frame RAS-10UAH-ES3, AS3 610 460 340 m3/h W RAS-4M27YAV-E, AS3 550 780 270 mm mm mm kg 35 30 Finned tube Propeller fan m /h 3 2030 2150 30 2030 2150 1740 20 1850 W W PA108X1T-4FZ1 750 Fuse, Overload relay Automatic louver C 15 ~ 43 -10 ~ 24 15 ~ 43 -4- FILE NO. SVM-04001 MODEL ITEM Capacity 220V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB dB kg mm mm 44 3. 10 0. 66 97 2. 15 RAS-07UKP-ES3 RAS-07UA-ES3 Cooling 240V 2. 18 1 220 - 240 50 0. 68 90 0. 15 3. 15 12 0. 8 38/32/26 45 R410A 0. 65 Capillary tube 9. 52 Flare connection 6. 35 Flare connection Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Outdoor (220-240V) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference INDOOR UNIT Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range Model Output Width Depth Width Depth Refrigerant control m m mm mm mm kg 10*1 5 RAS-07UKP-ES3 275 790 208 10 Finned tube Cross flow fan m3/h m /h 3 570 460 340 20 Honeycomb woven filter with PP frame RAS-07UA-ES3 m3/h W mm mm mm kg 530 660 240 27 Finned tube Propeller fan m /h 3 1420 30 PA79X1T-4FZ5 605 Fuse, Overload relay Automatic louver 1520 W W C 15 ~ 43 -5- FILE NO. [. . . ] 8-4-4 CAUTION Failure to firmly install the unit may result in personal injury and property damage if the unit falls. In case of block, brick, concrete or similar type walls, make 5 mm dia. NOTE Secure four corners and lower parts of the installation plate with 4 to 6 mounting screws to install it. - 40 - FILE NO. SVM-04001 <How to connect the connecting cable> Wiring of the connecting cable can be carried out without removing the front panel. Insert the connecting cable (according to the local cords) into the pipe hole on the wall. Take out the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm from the front. Insert the connecting cable fully into the terminal block and secure it tightly with screws. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor unit. Connecting cable For RAS-13/10/07UK Cord clamp Terminal cover Screw 12 Terminal block 12 abo ut 1 5 cm Earth line Screw Screw Connecting cable Fig. 8-4-7 Earth line 60 mm 10 mm CAUTION Be sure to refer to the wiring system diagram labeled inside the front panel. Check local electrical cords and also any specific wiring instructions or limitations. For RAS-13/10UKH Terminal cover Cord clamp Terminal block 10 mm 50 mm Stripping length of the connecting cable Fig. 8-4-18 Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit. Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc. Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material. ) When bending a pipe, carefully do it, not to crush it. NOTE Hole should be made at a slight downward slant on the outdoor side. Do not rise the drain hose. Installation place A place which provides the spaces around the outdoor unit as shown in the left diagram. A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. A place where the operation noise and discharged air do not disturb your neighbors. When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. An allowable length of the connecting pipe is up to 10 m (RAS-10UA) or 15 m (RAS-13UA). An allowable height level is up to 5 m (RAS-10, 07UA) or 6 m (RAS-13UA). [. . . ] 2) Remove the center shaft of the horizontal louver from the back body. - 67 - Remarks 2 2 2 2 4-Screws 3 2 Screws 3 Drain guide 5 TC Sensor 6 Screw 4 3-Connectors 6 Screw 3 Left shaft 2 Center shaft FILE NO. Part name Procedures Remarks 4 Heat exchanger 1) Remove the front panel, electrical part and the horizontal louver following procedure 3. 4) Remove the 2 screws on the heat exchanger at the 2 fixed plates (upper and lower) from the back body, and then pull out the upper side of the heat exchanger slowly. 2 Pipe holder 3 2-Screws 4 2-Screws 5 Cross flow fan 1) Remove the front panel, electrical part, horizontal louver and the heat exchanger following procedure 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-4M27YAV-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-4M27YAV-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.