User manual TOSHIBA RAS-4M27GAV-E DATA BOOK

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TOSHIBA RAS-4M27GAV-E. We hope that this TOSHIBA RAS-4M27GAV-E user guide will be useful to you.


TOSHIBA RAS-4M27GAV-E DATA BOOK: Download the complete user guide (51 Ko)

You may also download the following manuals related to this product:

   TOSHIBA RAS-4M27GAV-E (821 ko)
   TOSHIBA RAS-4M27GAV-E INSTALLATION MANUAL (1167 ko)
   TOSHIBA RAS-4M27GAV-E DOCUMENTATION COMMERCIALE (1545 ko)
   TOSHIBA RAS-4M27GAV-E SERVICE MANUAL (3742 ko)
   TOSHIBA RAS-4M27GAV-E INSTALLATION MANUAL (290 ko)

Manual abstract: user guide TOSHIBA RAS-4M27GAV-EDATA BOOK

Detailed instructions for use are in the User's Guide.

[. . . ] OPERATION DESCRIPTION 7-1 7-2 7-3 7-4 7-5 7-6 Outline of Air Conditioner Control Description of Operation Circuit Hi POWER Mode High-Temperature Limit Control Low-Temperature Limit Control Auto Restart Function 7-7 Filter Check Lamp 8. INSTALLATION PROCEDURE 8-1 8-2 8-3 8-4 8-5 8-6 8-7 9-1 9-2 9-3 9-4 9-5 9-6 Safety Cautions Installation Diagram of Indoor and Outdoor Units Installation Indoor Unit Outdoor Unit How to Set Remote Control Selector Switch Others Troubleshooting Procedure Basic Check Items Primary Judgement Self-Diagnosis by Remote Control (Check Code) Troubleshooting Flowcharts Troubleshooting for Remote Control (Including The Indoor P. C. PARTS REPLACEMENT 10-1 10-2 10-3 10-4 11-1 11-2 11-3 11-4 11-5 Indoor Unit Outdoor Unit (RAS-13UA-ES) Outdoor Unit (RAS-4M27GAV-E) Outdoor Unit (RAS-07UA-ES) Indoor Unit (E-Parts Assy) Indoor Unit Outdoor Unit (RAS-13UA-ES) Outdoor Unit (RAS-4M27GAV-E) Outdoor Unit (RAS-07UA-ES) 11. EXPLODED VIEWS AND PARTS LIST · This air conditioner is charged with HFC (R-410A) that doesn't deplete the Ozone layer. [. . . ] (Use polyethylene foam as insulating material. ) Rear right 4 mm How to fix the drains cap 1) Insert hexagonal wrench (4 mm) in a center head. Left Bottom right Right Die-cutting Front panel slit Bottom left Changing drain hose Rear left Piping preparation Fig. 8-4-15 2) Firmly insert drains cap. No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Die-cutting Front panel slit For leftward connection, cut out slit on the left side of the front panel. Changing drain hose For leftward connection, bottom leftward connection and rear leftward connection's piping, it is necessary to change the drain hose and drain cap. How to remove the drains cap Clip drain cap by needle-nose plier, and pull out. Fig. 8-4-16 CAUTION Firmly insert the drain hose and drain cap; otherwise, water may leak. <In case of right or left piping> · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. Fig. 8-4-13 How to install the drain hose Firmly insert drain hose connecting part until hitting on a heat insulator. Slit Fig. 8-4-17 <In case of bottom right or bottom left piping> Heat insulator · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. Drain hose Fig. Indoor unit fixing Bend the connecting pipe so that it is laid within 43 mm 1. Pass the pipe through the hole in the wall, and hook above the wall surface. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always exposed to strong wind like a coast or on a high storey of a building, secure the normal fan operation using a duct or a wind shield. In particularly windy areas, install the unit such as to avoid admission of wind. · A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment. Drain hose Inside the room Extension drain hose Fig. 8-4-23 CAUTION Arrange the drain pipe for proper drainage from the unit. This air conditioner has the structure designed to drain water collected from dew, which forms on the back of the indoor unit, to the drain pan. Therefore, do not store the power cord and other parts at a height above the drain guide. Wall Drain guide Strong wind Space for pipes Fig. Cut the pipe with a pipe cutter. Obliquity Roughness Warp (Unit : N·m) Outer dia. of copper pipe 6. 35 mm 9. 52 mm Tightening torque 16 to 18 (1. 6 to 1. 8 kgf·m) 33 to 42 (3. 3 to 4. 2 kgf·m) 90° Fig. · Projection margin in flaring : A (Unit : mm) A · Tightening torque of flare pipe connections The operating pressure of R-410A is higher than that of R-22. It is therefore necessary to firmly tighten the flare pipe connecting sections (which connect the indoor and outdoor units) up to the specified tightening torque. [. . . ] Remarks 2 Pipe holder 3 2-Screws 4 2-Screws 5 Cross flow fan 1) Remove the front panel, electrical part, horizontal louver and the heat exchanger following procedure 4. 2) Remove the 2 screws on the band motor (L) and remove the 2 screws on the band motor (R) and then remove the cross flow fan. 3) Loosen the set screw of the cross flow fan then separate the fan and the fan motor. Notice To assemble cross flow fan and fan motor to the unit, please turn the fan motor unit the center of its terminal meets the lowest point of band motor (R) (point A). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-4M27GAV-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-4M27GAV-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.